Thermo Scientific™

Vanquish™ Dual Split Sampler

Catalog number: VF-A40-A-02
Have Questions?
Thermo Scientific™

Vanquish™ Dual Split Sampler

Catalog number: VF-A40-A-02
Have Questions?

Improve productivity using the Thermo Scientific™ Vanquish™ Dual Split Sampler. Designed to support Thermo Scientific™ Vanquish™ Duo UHPLC system for Dual LC, this unique biocompatible autosampler combines two injection devices in one housing, resulting in two separate channels that are individually controllable (injector volume, wash cycles, etc.). Choose between the 1000 bar or 1500 bar option.


View HPLC/UHPLC resources

 
Catalog Number
VF-A40-A-02
Unit Size
Each
Description
Vanquish Dual Split Sampler FT
Price (USD)
Full specifications
TypeDual Split Sampler FT
Injection Cycle TimeDown to 8 s depending on separation conditions
Injection Volume Precision< 0.25% area RSD for 1 μL (caffeine aq. soln.)<br /> Typically < 0.5% area RSD for 0.5 μL (caffeine aq. soln.)
Injection Volume Range0.01 to 25 μL, min. step = 0.01 μL; Optional: 0.01 to 100 μL
Injection TypeSplit Loop, 2 Injection Units
Sample Capacity4 Segments for Sample Racks or Well Plates with SBS Footprint Format; 12 x 22.5 mm O.D. Vials
Max. Pressure1034 bar
Biocompatible VersionYes, pH range 2–12, chloride concentration up to 1mol/L
Wetted Parts: Sample flow path: Titanium, Ceramics, PEEK, MP35N, DLC
Eluent Flow Path: MP35N, Titanium, Sapphire, PEEK, PTFE, Ceramics, DLC
Wash Liquid Flow Path: Silicone, PP, FFPM, PEEK, PA
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
Weight (Metric)29 kg
DescriptionVanquish Dual Split Sampler FT
Carryover< 0.002% with caffeine (typically: < 0.0004%), UV
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Vanquish Dual Split Sampler HT
Price (USD)
Full specifications
TypeDual Split Sampler HT
Injection Cycle TimeDown to 8 s depending on separation conditions
Injection Volume Precision< 0.25% area RSD for 1 μL (caffeine aq. soln.)<br /> Typically < 0.5% area RSD for 0.5 μL (caffeine aq. soln.)
Injection Volume Range0.01–25μL, min. step = 0.01μL; Optional: 0.01–100μL
Injection TypeSplit Loop, 2 Injection Units
Sample Capacity4 Segments for Sample Racks or Well Plates with SBS Footprint Format; 12 x 22.5 mm O.D. Vials
Max. Pressure1500 bar
Biocompatible VersionYes, pH range 2–12, chloride concentration up to 1mol/L
Wetted Parts: Sample flow path: Titanium, Ceramics, PEEK, MP35N, DLC
Eluent Flow Path: MP35N, Titanium, Sapphire, PEEK, PTFE, Ceramics, DLC
Wash Liquid Flow Path: Silicone, PP, FFPM, PEEK, PA
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
Weight (Metric)29 kg
DescriptionVanquish Dual Split Sampler HT
Carryover< 0.002% with caffeine (typically: < 0.0004%), UV
Dimensions (L x W x H)

Split loop autosampler with two injection units with barcode reading:

  • Empty segment detection
  • Rack/well plate verification
  • Inventory management

Sample capacity (can be extended with optional Thermo Scientific Charger Module) of any four of the following (SBS footprint):

  • 54 x 12mm OD vials (≤ 1.5mL)
  • 96 x 6, 7 and 8mm OD vials (≤ 1.2mL)
  • 24 x 15mm OD vials (≤ 4mL)
  • well plates (96 and 384, deep and shallow)

In addition to 12 x 22.5mm OD vials (≤ 10mL) in the carousel

Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
VF-A40-A-02Full specifications
EachVanquish Dual Split Sampler FTRequest A Quote
TypeDual Split Sampler FT
Injection Cycle TimeDown to 8 s depending on separation conditions
Injection Volume Precision< 0.25% area RSD for 1 μL (caffeine aq. soln.)<br /> Typically < 0.5% area RSD for 0.5 μL (caffeine aq. soln.)
Injection Volume Range0.01 to 25 μL, min. step = 0.01 μL; Optional: 0.01 to 100 μL
Injection TypeSplit Loop, 2 Injection Units
Sample Capacity4 Segments for Sample Racks or Well Plates with SBS Footprint Format; 12 x 22.5 mm O.D. Vials
Max. Pressure1034 bar
Biocompatible VersionYes, pH range 2–12, chloride concentration up to 1mol/L
Wetted Parts: Sample flow path: Titanium, Ceramics, PEEK, MP35N, DLC
Eluent Flow Path: MP35N, Titanium, Sapphire, PEEK, PTFE, Ceramics, DLC
Wash Liquid Flow Path: Silicone, PP, FFPM, PEEK, PA
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
Weight (Metric)29 kg
DescriptionVanquish Dual Split Sampler FT
Carryover< 0.002% with caffeine (typically: < 0.0004%), UV
Unit SizeEach
VH-A40-A-02Full specifications
EachVanquish Dual Split Sampler HTRequest A Quote
TypeDual Split Sampler HT
Injection Cycle TimeDown to 8 s depending on separation conditions
Injection Volume Precision< 0.25% area RSD for 1 μL (caffeine aq. soln.)<br /> Typically < 0.5% area RSD for 0.5 μL (caffeine aq. soln.)
Injection Volume Range0.01–25μL, min. step = 0.01μL; Optional: 0.01–100μL
Injection TypeSplit Loop, 2 Injection Units
Sample Capacity4 Segments for Sample Racks or Well Plates with SBS Footprint Format; 12 x 22.5 mm O.D. Vials
Max. Pressure1500 bar
Biocompatible VersionYes, pH range 2–12, chloride concentration up to 1mol/L
Wetted Parts: Sample flow path: Titanium, Ceramics, PEEK, MP35N, DLC
Eluent Flow Path: MP35N, Titanium, Sapphire, PEEK, PTFE, Ceramics, DLC
Wash Liquid Flow Path: Silicone, PP, FFPM, PEEK, PA
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
Weight (Metric)29 kg
DescriptionVanquish Dual Split Sampler HT
Carryover< 0.002% with caffeine (typically: < 0.0004%), UV
Dimensions (L x W x H)

Split loop autosampler with two injection units with barcode reading:

  • Empty segment detection
  • Rack/well plate verification
  • Inventory management

Sample capacity (can be extended with optional Thermo Scientific Charger Module) of any four of the following (SBS footprint):

  • 54 x 12mm OD vials (≤ 1.5mL)
  • 96 x 6, 7 and 8mm OD vials (≤ 1.2mL)
  • 24 x 15mm OD vials (≤ 4mL)
  • well plates (96 and 384, deep and shallow)

In addition to 12 x 22.5mm OD vials (≤ 10mL) in the carousel

Unit SizeEach
Showing 2 of 2
Dual sample injection—highest productivity, fastest return on investment

Vanquish Dual Split Samplers are made for Vanquish Duo system for Dual LC. These fully biocompatible autosamplers are optimized for the highest level of ruggedness and uptime even under tough system pressure and eluent conditions.

  • Improves productivity by using two independent injections units controlled independently from a single user interface with full traceability with Thermo Scientific™ Chromeleon™ Chromatography Data System (CDS)
  • Increases sample rack throughput and capacity without changing validated methods
  • Increase capacity without sacrificing bench space
  • Tracks sample configuration with automated barcode reading
  • Boosts return on investment by reducing cost per sample
  • Analyzes the same set of samples with multiple methods reducing sample preparation time and maximizing sample information

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text