Orion™ 2295 Phosphate Analyzer
Orion™ 2295 Phosphate Analyzer
Thermo Scientific™

Orion™ 2295 Phosphate Analyzer

Our Thermo Scientific™ Orion™ 2295 Phosphate Analyzer is designed to provide continuous and online measurement of phosphates.
Have Questions?
Número de catálogo 229500
Precio (ARS)/ Each
-
Descripción:
Orion™ 2295 Phosphate Analyzer
Intervalos de medición:
0.2 to 50ppm auto-ranging or user Programmable.
Bucles de corriente:
Two 0/4-20mA – Direct or Reverse Acting (Isolated). Maximum 900ohm load.
Requisitos eléctricos:
100 to 240VAC 50/60Hz
Phosphates are widely found in industrial water treatments, fertilizers, biological treatments, heat exchangers and other applications. Our Thermo Scientific™ Orion™ 2295 Phosphate Analyzer is designed to provide continuous and online measurement of phosphates. Monitoring and control of phosphate levels reduces the formation of scaling, microorganisms and other effects that decrease equipment efficiency. The optimized design of the Orion 2295 Phosphate Analyzer leads to reduced reagent consumption and a lower cost of ownership. Thermo Scientific™ products are designed to provide fast, accurate and reliable online phosphate detection – optimized for applications that require early detection of dissolved phosphates.
  • Optimized reagent consumption – designed to allow for 45 days between reagent changes
  • Designed to provide accurate and precise measurements – allowing for fine control of the phosphate dosing process
  • Compact size – small footprint supports panel or wall mounting
  • Simplified operation – intuitive menu simplifies navigation
  • Low operating costs – minimal maintenance with low power consumption
  • On-demand mode for non-continuous operation – allows analyzer to be returned to on-line mode rapidly after a plant is started up
Especificaciones
ExactitudLess than 5% of reading or ±0.5ppm, whichever is greater, from 0.2 to 50ppm.
Detalles de comunicaciónRS232 ASCII protocol for data reporting
Bucles de corrienteTwo 0/4-20mA – Direct or Reverse Acting (Isolated). Maximum 900ohm load.
DescripciónOrion™ 2295 Phosphate Analyzer
Límites de detección0.2ppm
Temperatura de funcionamiento (métrico)5°C to 45°C
TipoPhosphate Analyzer
Clasificación de carcasaNEMA12 (Electronics cabinet), NEMA4X (Fluidics cabinet)
Caudal50 to 1000mL/min
Entrada/salida1/4 in. O.D. flexible tubing, polypropylene or similar material
Humedad relativa máx.90% at 40°C
Intervalos de medición0.2 to 50ppm auto-ranging or user Programmable.
MétodosOptical absorption at 470nm
Detalles de la normativaSafety CE: EN/IEC61010-1, cTUVus; EMC CE: EN61326; FCC Part 15 Class A
Detalles del reléFour SPDT, 2A at 240V - Programmable
RepetibilidadLess than ±3% of reading or ±0.1ppm, whichever is greater from 0.2 to 50ppm.
Resolución0.1ppm in all ranges
Tiempo de respuestaLess than 10 minutes per analysis
Presión de la muestra5psi max.
Flujos de muestrasOne
Suministro de muestrasContinuous
Sólidos suspendidosLess than 60μm
Temperatura de funcionamiento (imperial)41° to 113°F
Dimensiones (Largo x Ancho x Alto)27.5 x 16 x 6.4 in. (698 x 406 x 162mm)
Longitud (imperial)27.5 in.
Longitud (métrico)698 mm
Anchura (imperial)16 in.
Anchura (métrico)406 mm
Altura (imperial)6.4 in.
Altura (métrico)162 mm
Peso (imperial)40 lb.
Peso (métrico)18 kg
Requisitos eléctricos100 to 240VAC 50/60Hz
Tensión100 to 240 VAC
Frecuencia50/60 Hz
Unit SizeEach