Thermo Scientific™

FHZ 691-10 Dose Rate Detector

Número de catálogo: 4254271
Thermo Scientific™

FHZ 691-10 Dose Rate Detector

Número de catálogo: 4254271
Detect even the smallest amounts of artificial radioactivity with a high sensitivity scintillation detector. The Thermo Scientific™ FHZ 691-10 probe is specially suited to detect dose rate increases as small as 3 percent at normal background within a measuring time of one minute. Using the Natural Background Rejection (NBR) algorithm, this low dose rate detector easily differentiates between artificial parts of radiation and fluctuations in the natural dose rate (e.g. caused by precipitation) in the surrounding environment.
 
Número de catálogo
4254271
Formato
Each
Descripción
FHZ 691-10 Dose Rate Detector
Precio (ARS)
Especificaciones completas
DescripciónFHZ 691-10 Dose Rate Detector
Tipo de detectorScintillation
Intervalo de mediciónH*(10): Low dose detector NaI(Tl): 0.01 μSv/h to 0,5 mSv/h
High dose detector (GM): 0.5 mSv/h to 10 Sv/h
SensibilidadLow dose detector: 160 cps/(μSv/h)
High dose detector : 17 cps/(mSv/h)
Peso (métrico)520 g
Intervalo de energíaH*(10): 60 keV to 3 MeV
tempAngular: - 45° bis 45°
Temperatura de almacenamiento (métrico)- 40°C bis + 70°C
Tipo de productoDose Rate Detector
Dimensiones (métrico)Diameter: 65 mm
Length: 257 mm (without plug-in connection)
ClaseProtection class: IP67 in accordance DIN 40050/EN60529
Dosis del detector permitida10 Sv
Operating Limit Temperature Range (Metric)- 30°C bis + 55°C
Unit SizeEach
Mostrando 1 de 1
Número de catálogoEspecificacionesFormatoDescripciónPrecio (ARS)
4254271Especificaciones completas
EachFHZ 691-10 Dose Rate DetectorContáctenos ›
DescripciónFHZ 691-10 Dose Rate Detector
Tipo de detectorScintillation
Intervalo de mediciónH*(10): Low dose detector NaI(Tl): 0.01 μSv/h to 0,5 mSv/h
High dose detector (GM): 0.5 mSv/h to 10 Sv/h
SensibilidadLow dose detector: 160 cps/(μSv/h)
High dose detector : 17 cps/(mSv/h)
Peso (métrico)520 g
Intervalo de energíaH*(10): 60 keV to 3 MeV
tempAngular: - 45° bis 45°
Temperatura de almacenamiento (métrico)- 40°C bis + 70°C
Tipo de productoDose Rate Detector
Dimensiones (métrico)Diameter: 65 mm
Length: 257 mm (without plug-in connection)
ClaseProtection class: IP67 in accordance DIN 40050/EN60529
Dosis del detector permitida10 Sv
Operating Limit Temperature Range (Metric)- 30°C bis + 55°C
Unit SizeEach
Mostrando 1 de 1

The FHZ 691-10 intelligent probe is used for H*(10) ambient equivalent dose rate measurements over a dynamic range of 9 decades. 

  • High measuring accuracy, 3% at 100 nSv/h in 1 min.
  • ADF filter for filtering statistical fluctuations and fast reaction to changes. 
  • PTB type approval for calibration in combination with the display unit FHT 6020P. 
  • RS-485 interface. 
  • Transfer protocol with very short reaction times for monitoring networks. 
  • Extended self checks for probe functions.
  • Surge protection for all inputs and outputs.

Figuras

Documentos y descargas

Certificados

    Preguntas frecuentes

    Citas y referencias

    Search citations by name, author, journal title or abstract text