Check the performance and accuracy of your spectrophotometer right in your own laboratory using the Thermo Scientific™ SPECTRONIC Standards, and holder.
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoPara utilizar con (equipo)Tipo
AQX1FLTRHDROrion AquaMate 7100/8100Sample Holder for Film/Filter
840-253100TSSample Holder for Film/FilterGlass Standards
Número de catálogo AQX1FLTRHDR
Precio (USD)
-
Para utilizar con (equipo):
Orion AquaMate 7100/8100
Tipo:
Sample Holder for Film/Filter

Calibration standards and film / filter holders ensure the accuracy of your AquaMate 7100 and 8100 Spectrophotometers. Check the performance and accuracy of your spectrophotometer right in your own laboratory using the Thermo Scientific™ SPECTRONIC Standards, and holder.

Sold separately, calibration standards and film / filter holders insure the accuracy of your AquaMate 7100 and 8100 Spectrophotometers.

Part number 840-253100 Includes:

Set of 7 glass pieces mounted in metal frames sized to fit standard square cuvette holders.

  • Four calibrated neutral density glass standards for checking photometric accuracy at nominal values of 0.3A, 0.5A, 1A and 1.5A◦Standards are calibrated at 440.0n, 465.0nm, 546.1nm, 590.0nm and 635.0nm
  • One calibrated standard for checking wavelength accuracy at nominal wavelengths on 400nm, 522nm and 777nm◦The symmetry of the peaks means that tests of wavelength accuracy are independent of the spectral bandwidth (between 1nm and 10nm) of the instrument being tested
  • filter for checking stray light in UV-Vis instruments at 220nm
  • 1 filter for checking stray light in Vis instruments at 400nm
  • Each set of SPECTRONIC Standards is individually tested and certified to be accurate, with values traceable to the National Institute of Standards and Technology (NIST) or other Primary Standards
  • Filters are supplied in a tough plastic storage container

Recalibration service is available from Thermo Fisher Scientific. Recommended recalibration interval is two years.

Part Number AQX1FLTRHDR includes:

Film/Filter holder filters/lenses up to 50 mm long x 80 mm tall x 10 mm thick for Orion™ AquaMate 7100 & 8100 Spectrophotometers

Especificaciones
Para utilizar con (equipo)Orion AquaMate 7100/8100
AdmiteFilters/lenses up to 50 mm long, 80 mm tall and 6 mm thick
Incluye1 Film / Filter Holder
TipoSample Holder for Film/Filter