1x1 image pixel for data collection
TaqMan™ MGB Probe
TaqMan™ MGB Probe
Applied Biosystems™

TaqMan™ MGB Probe

Green features
Applied Biosystems TaqMan MGB (Minor Groove Binder) Sonden sind doppelt markierte Sonden, die für Echtzeit-PCR-Anwendungen mit TaqMan Chemie verwendet werden.InWeitere Informationen
Promo ImageSonderaktionen
Werbeaktionscode:P5780456
Gene Expression Promo
From RNA Isolation kits, reverse transcriptases to analysis of your gene with qPCR - upto 35% on all Gene Expression workflow productsWeitere Informationen
Have Questions?
Ansicht ändernbuttonViewtableView
KatalognummerMenge
4316033Promo Image20,000 pmol Scale
4316034Promo Image6.000 pmol-Skala
4316032Promo Image50,000 pmol Scale
Katalognummer 4316033
Preis (EUR)
864,65
Online Exclusive
1.058,00
Ersparnis 193,35 (18%)
Each
Jetzt bestellen
Menge:
20,000 pmol Scale
Applied Biosystems TaqMan MGB (Minor Groove Binder) Sonden sind doppelt markierte Sonden, die für Echtzeit-PCR-Anwendungen mit TaqMan Chemie verwendet werden.In TaqMan MGB-Sonden ist einen fluoreszierender Reporter-Farbstoff am 5'-Ende und einen nicht fluoreszierender Quencher (NFQ) am 3'-Ende eingebunden.Der Vorteil eines NFQ besteht in dem geringeren Hintergrundsignal, wodurch die Quantifizierung präziser ist.Kundenspezifische TaqMan MGB-Sonden sind HPLC-gereinigt und mit FAM-, VIC-, TET- und NED-Reporterfarbstoffen erhältlich.

Kürzere und spezifischere Sonden
TaqMan MGB-Sonden enthalten einen MGB-Anteil am 3’-Ende, der die Schmelztemperatur (Tm) der Sonde erhöht und Sonden- bzw. Zielhybride stabilisiert.Dies bedeutet, dass TaqMan MGB-Sonden deutlich kürzer als herkömmliche Sonden sein können, wodurch eine bessere Sequenzunterscheidung und mehr Flexibilität bei der Erfassung mehrerer Ziele ermöglicht wird.

Nicht fluoreszierender Quencher (NFQ) maximiert die Empfindlichkeit
TaqMan MGB-Sonden enthalten am anderen Ende der Sonde einen NFQ zur Absorption (zum Quenchen) des Signals des fluoreszierenden Farbstoffmarkers.Die Eigenschaften des NFQ in Kombination mit der kurzen Länge der MGB-Sonde führen zu einem niedrigeren Hintergrundsignal als bei NFQ-Sonden ohne MGB.Geringerer Hintergrund bedeutet höhere Empfindlichkeit und präzisere Daten.

Garantierte Ausbeute
Die von Ihnen ausgewählte Einheitsgröße basiert auf der von uns zu liefernden Mindestmenge und nicht auf der Ausgangsmenge für die Synthese.

Ungefähre Lieferzeit
4–6 Tage in Nordamerika, 5 bis 10 Tage in Europa

Wir bieten auch:
•Applied Biosystems kundenspezifische Primer und andere Arten von TaqMan Sonden.Mehr erfahren ›
• TaqMan MGB-Sonden und Primer, die als vorab entwickelte und formulierte TaqMan Assays erhältlich sind.Mehr erfahren ›
• Produkte und Dienstleistungen für die kommerzielle Herstellung, einschließlich OEM- und GMP-Oligo-Herstellung.Mehr erfahren ›

Sie benötigen einen anderen Farbstoff oder eine größere Menge?Der kundenspezifische TaqMan Assay und Oligo-Service bietet kundenspezifische Produkte gemäß Ihren experimentellen Anforderungen.Weitere Informationen ›

Nur für Forschungszwecke. Nicht zur Verwendung bei diagnostischen Verfahren.
Specifications
3'-Primer-ModifizierungMGB-NFQ
5'-Primer-ModifizierungFAM, NED, TET, VIC
Zur Verwendung mit (Geräte)7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex, QuantStudio™ Absolute Q Digital PCR System
FormatTube
Umweltfreundliche EigenschaftenNachhaltige Verpackung
Interne SondenmodifikationKeine
ProduktlinieTaqMan™
ProdukttypTaqMan Sonde
ReinigungsverfahrenHPLC
Reinheits- oder QualitätsgradHPLC
Menge20,000 pmol Scale
VersandbedingungRaumtemperatur
Zur Verwendung mit (Anwendung)Real-Time PCR (qPCR)
FormFlüssig
Marker oder FarbstoffVIC
Unit SizeEach
Inhalt und Lagerung
1 Röhrchen mit einer doppelt markierten Sonde in Lösung.

Bei -15 bis -25 °C lagern

Häufig gestellte Fragen (FAQ)

I would like to calibrate my Real-Time PCR instrument with a custom dye, which buffer should I use?

Please ask your dye manufacturer for recommendations. If there is no specific recommendation available, try TE Buffer (pH 8.0) to start.

I need to see all the primer and probe sequences from an assay design right away. How can I do this?

You can directly see all the primer and probe sequences from a test design right away using the Primer Express Software. Open the software and choose File => New. Choose either TaqMan MGB Quantification or TaqMan Quantification for Gene Expression Assay design. Copy/paste your gene sequence of interest into the new window and click on the green triangle to get primer/probe designs.

Find additional tips, troubleshooting help, and resources within our Real-Time PCR and Digital PCR Instruments Support Center.

How can I determine whether the Tm of my custom probe is appropriate?

In general, the target Tm of a TaqMan probe is 70 degrees C. Using the Primer Express Software, you can check the Tm of a MGB or TAMRA probe probe.

Within the software, go to Primer Probe Test Tool and then copy/paste in your sequence of interest to see the Tm. If you need to check for a MGB based probe, make sure to choose Document Type: TaqMan MGB Quantification. If you need to check for a QSY or TAMRA based probe, make sure to choose Document Type: TaqMan Quantification. Real-Time PCR and Digital PCR Applications

Find additional tips, troubleshooting help, and resources within our Real-Time PCR and Digital PCR Applications Support Center.

I have purchased custom oligos (primers and probes) and I want to make a 20x working stock for a TaqMan assay, similar to the pre-designed assays. How do I dilute and mix my oligos to make a 20x working stock?

Most pre-designed TaqMan assays are supplied as a 20x assay concentrate containing 18 uM of each primer and 5 uM of probe which provides a 900 nM of each primer and 250 nM of the probe (for gene expression assays) and 200 nM of each probe (for SNP genotyping assays) at the final 1x concentration.

In order to make a 20x working stock from custom oligos, the oligos need to be diluted as follows: To make a 20x Assay stock for Gene Expression assays, make 100 uM stocks of both forward and reverse primers, and TaqMan probe. Add 18 ul of each primer and 5 ul of the TaqMan probe, which gives 41 ul volume. Add 59 ul of 1X TE to bring the volume to 100 ul of 20X TaqMan Gene Expression Assay. To make a 20x Assay stock for a Genotyping Assay, make 100 uM stocks of both forward and reverse primers, and both TaqMan probes. Add 18 ul of each primer and 4 ul of each TaqMan probe, which gives 44 ul volume. Add 56 ul of 1X TE to bring the volume to 100 ul of 20X TaqMan SNP Genotyping Assays.

I am looking to order a molecular probe for validation, using specific sequences. How do I order a custom probe?

We do not offer any custom probes for diagnostic purposes.

We do offer custom TaqMan probes for qPCR experiments, which are for Research Use Only.
TaqMan MGB Probe
TaqMan QSY Probe
TaqMan TAMRA Probe
These above probes can be designed in our online tool, Custom TaqMan Probes.

If you would like to order a pre-mix of primers and probe, please check our custom TaqMan Assays.
You can find more information one the Custom TaqMan Gene Expression Assay page on thermofisher.com.

Find additional tips, troubleshooting help, and resources within our Real-Time PCR and Digital PCR Applications Support Center.

Dokumente und Downloads

Zertifikate

Sicherheitsdatenblätter

Geben Sie die Katalognummer, den Namen oder Link frei.

1x1 image pixel for data collection