Pharma KingFisher™ Flex 96 Standardplatten
Pharma KingFisher™ Flex 96 Standardplatten
Applied Biosystems™

Pharma KingFisher™ Flex 96 Standardplatten

These standard plates are for use with the Pharma KingFisher Flex 96 Deep-Well Head Magnetic Particle Processor or MagMAX Express-96Weitere Informationen
Have Questions?
KatalognummerMenge
A4307648 plates
Katalognummer A43076
Preis (EUR)
215,00
Each
Zum Warenkorb hinzufügen
Menge:
48 plates
Preis (EUR)
215,00
Each
Zum Warenkorb hinzufügen
These standard plates are for use with the Pharma KingFisher Flex 96 Deep-Well Head Magnetic Particle Processor or MagMAX Express-96 Standard Magnetic Particle Processor in combination with PrepSEQ ResDNA kits and ProteinSEQ kits. The standard configuration differs from the deep-well configuration in that the volume of sample input is from 20–200 μL per well compared to 100–1000 μL per well for the deep-well configuration.

Optimize performance using KingFisher Flex System consumables designed specifically for use with these instruments. KingFisher Flex disposable plastics (tip combs and microplates) are made of polypropylene and are ideal for magnetic particle processing because of their low binding affinity for biomolecules. Their special design enables excellent recovery of magnetic beads.

Nur für Forschungszwecke. Nicht zur Verwendung bei diagnostischen Verfahren.

Specifications
Zur Verwendung mit (Geräte)KingFisher™ Flex
Verpackung48 Platten
ProdukttypMikrotiterplatte
Menge48 plates
VersandbedingungRaumtemperatur
BarcodeKein Barcode
FarbeDurchsichtig
MaterialPolypropylen
Anzahl Wells96
ProduktlinieKingFisher Flex
Volumen (metrisch) Well1000 μl
Unit SizeEach
Inhalt und Lagerung
48-Well- (Standard), 96-Well-Platten

Häufig gestellte Fragen (FAQ)

My Pharma KingFisher Flex run was stopped due to an error message. Can I start the protocol from where it stopped?

No, once a protocol was stopped, it will restart from the beginning. The extraction procedure can either be finished manually by using a magnetic stand, or a modified version of the original Pharma KingFisher Flex script would have to be created that starts off at the point where the run was stopped.

Is it always necessary to use the transport locks on the Pharma KingFisher Flex instrument?

The transport locks are only necessary when relocating the instrument.

Are the volumes of reagents in each well critical for a successful Pharma KingFisher Flex run?

We strongly recommend that you maintain the specified volumes within the defined limits to avoid spillover and to help ensure the best performance at the most efficient level.

What if the magnetic particles are attached to the tip combs after my Pharma KingFisher Flex run?

This happens sometimes but it will not affect the yield because the sample has been released from the particles.

What if the magnetic particles remain in the sample well during a Pharma KingFisher Flex run?

If the starting material is too viscous, the magnetic rods will not be able to collect the particles. Dilute the sample and check that the sample is properly homogenized/lysed. Adding low amounts of detergent will improve the collection of magnetic particles as well. Quickly centrifuge the plate to sediment the particles to the bottom of the plate.

Dokumente und Downloads

Zertifikate

Sicherheitsdatenblätter

Geben Sie die Katalognummer, den Namen oder Link frei.