DHX™ Heat Exchanger BioProcess Container (BPC), ASI™ 26/77 film, ReadyMate connections, drain ports, three 6-L BPCs
DHX™ Heat Exchanger BioProcess Container (BPC), ASI™ 26/77 film, ReadyMate connections, drain ports, three 6-L BPCs
Thermo Scientific™

DHX™ Heat Exchanger BioProcess Container (BPC), ASI™ 26/77 film, ReadyMate connections, drain ports, three 6-L BPCs

The Thermo Scientific™ DHX™ Heat Exchanger Single-Use BioProcess Container (BPC) is a 2D system consisting of three 6 L BPCs,Weitere Informationen
Have Questions?
Katalognummer DX00012I
auch als DX00012-I bezeichnet
Preis (EUR)/ 3 x 6 L
-
Angebot anfordern
The Thermo Scientific™ DHX™ Heat Exchanger Single-Use BioProcess Container (BPC) is a 2D system consisting of three 6 L BPCs, with drain. It is composed of Thermo Scientific™ ASI™ 26/77 Polyethylene Film, with interconnecting TPE tubing and ReadyMate DAC end connections. The DHX Heat Exchanger and DHX BPC each features a serpentine pattern, creating a sterile fluid path for the process fluid. The BPC fits tightly between the stainless steel DHX Heat Exchanger plate system, and after loading, no further operator interaction is required. The customer has the option of utilizing up to 4 BPCs in the DHX unit.

Features
• Eliminates post-use cleaning steps required with reusable containers, helping to reduce cross-contamination risks
• Provides sterile processing environment without the cost and time of clean-in-place or steam-in-place sterilization (CIP/SIP)
• Minimizes bioburden by using the DHX Heat Exchanger unit and DHX BPCs to address weak points in a CIP system or sanitation process (typically required for stainless steel equipment)
• Reduces maintenance and life cycle cost due to its unique design
• Increases volume capacity via parallel connection between DHX units

Applications
• cGMP commercial and clinical biotherapeutics, vaccines, and other biologic processes
• Upstream applications, including media hold, harvest cooling, and harvest hold
• Downstream applications, including harvest hold, buffers, protein purification, and bulk drug substance

Specifications
Kapazität (metrisch)18 L
AbmessungenEach BPC: 62.2 cm x 61.9 cm (24.5 in. x 24.4 in.)
Zur Verwendung mit (Geräte)DHX1001
FilmbeschreibungASI™ 26/77
AußenverpackungTwo 4-mil. poly bags
AnschlussdetailReadyMate DAC connectors and drain port
MaterialPolyethylene
Innere SchutzverpackungProtective material around rough areas
VersandbedingungRoom Temperature
SterilisationsmethodeGamma Irradiated
ProduktlinieDHX
Tubing StyleTPE, ID x OD: 0.64 x 12.7 cm (0.25 in. x 0.5 in.)
Unit Size3 x 6 L
Inhalt und Lagerung
Store at room temperature.