HFM11 Series Hand and Foot Monitors
HFM11 Series Hand and Foot Monitors
Das tatsächliche Produkt kann abweichen
Thermo Scientific™

HFM11 Series Hand and Foot Monitors

Help to reduce monitoring times; the longer hand detectors provide wrist and forearm coverage and there is an optional frisker probe available for additional monitoring.
Have Questions?
Ansicht ändernbuttonViewtableView
KatalognummerDetektorenBeschreibung
HFM11A-GF6: 4 Hands, 2 FeetGas flow detector counters 4 hand, 2 foot
HFM11A-GF-P1R7: 4 Hands, 2 Feet, 1 frisking probeGas flow detect counters 4 hand, 2 foot, frisker housing
HFM11A-SC6: 4 Hands, 2 FeetAlpha Beta scintillation (4 hand and 2 foot detectors)
HFM11A-SC-P3R7: 4 Hands, 2 Feet, 1 frisking probeAlpha Beta scintillation (fisker housing detectors)
4 Optionen
Katalognummer HFM11A-GF
Preis (EUR)/ Each
-
Angebot anfordern
Detektoren:
6: 4 Hands, 2 Feet
Beschreibung:
Gas flow detector counters 4 hand, 2 foot

Thermo Scientific™ HFM11 Series high-efficiency Hand and Foot Monitors help to reduce monitoring times; the longer hand detectors provide wrist and forearm coverage and there is an optional frisker probe available for additional monitoring.

The HFM11 provides fast, thorough, hand and foot monitoring with class-leading reliability and ease of use.

The modular “X-channel” platform, with common controller boards and simple cabling, provides for easy, low cost maintenance. It also provides detector intelligence and powerful controller functionality—such as the automated calibration and source checking routines. The X-channel architecture also allows easy retro-fitting of options such as the frisker probe (not available with gas sealed).
  • Gas flow measurement handled electronically by on-screen flow graphs and leak and high/low flow alarms
  • Scanning software displays optimum voltage to minimize cross-talk between alpha and beta channels and discriminate between X radiation and other interfering radiations
  • Large color LCD touch-screen; no keyboard required
  • Low power consumption; no cooling fan needed, reducing debris intake
  • Solid state flash storage
  • Positioning sensors feature photobeams
  • Easy-to-maintain detector assemblies; no tools required
  • Hex mesh grills for greater detector protection
  • Audible and visual alarms
  • Alarm settings: By the use of large area calibrated sources or by touch-screen entry of calculated efficiencies
  • Background update time: 100 seconds rolling average, with checking for changing background
  • Monitoring time: Auto time, 1 to 100 s
  • Control: Audible, visual alarms if a hand or foot is out of position
  • Indications: Digital screen displays for alpha and beta levels for each hand and foot as well as magnitude and type of contamination
  • Probability of false alarm: 0.1 to 10 sigma in 0.1 sigma steps
  • Probability of detection: 0 to 10 sigma in 0.1 sigma steps
  • Self test: High Voltage, detector response, detector contamination and background level are monitored
  • Digital I/O connections: RS-232, Parallel printer port, Ethernet and USB
  • Model HFM11-GF offers gas flow (Ar/CH4 or Ar/CO2; flow rate 25 to 50cm3/min.)
  • Optional frisker probe available for additional monitoring

Includes:Sophisticated voltage scanning software

Specifications
Leistungsaufnahme83 W
Akustischer AlarmYes
BauweiseMetal base with Molded Top
BeschreibungGas flow detector counters 4 hand, 2 foot
Detektionsfläche2980 cm2
DisplaytypLCD
Höhe (angloamerikanisch)32.5 in.
Höhe (metrisch)825 mm
Hertz47 to 63 Hz
Tiefe (angloamerikanisch)32.5 in.
Tiefe (metrisch)825 mm
StrahlungstypAlpha, Beta
Bereich relative LuftfeuchtigkeitUp to 95% at 35°C (95°F), Non-Condensing
Betriebstemperatur (angloamerikanisch)41°F to 113°F
Betriebstemperatur (metrisch)5°C to 45°C
Stromversorgung85 to 264 VAC
Gewicht (angloamerikanisch)275 lb.
Gewicht (metrisch)125 kg
Breite (angloamerikanisch)34.5 in.
Breite (metrisch)876 mm
Detektoren6: 4 Hands, 2 Feet
Angezeigte EinheitenUser Selectable
EffizienzIsotope and detector dependant, see data sheet
Energiebereich60 to 8000 KeV
ProdukttypHand and Foot Monitor
MesszeitDependant on Sensitivity Required
Unit SizeEach