FHT 3031 CCM Conveyor Belt Monitor
FHT 3031 CCM Conveyor Belt Monitor
Actual product may vary
Thermo Scientific™

FHT 3031 CCM Conveyor Belt Monitor

Quickly and reliably checks large quantities of material for possible contamination using the Cobalt Coincidence Method (CCM).
Have Questions?
Change viewbuttonViewtableView
Catalog NumberDescription
FHT303112Conveyor belt Monitor (FHT 3031-12 CCM)
FHT30316Conveyor belt Monitor (FHT 3031-6 CCM)
2 Options
Catalog number FHT303112
Price (EUR)/ Each
-
Request A Quote
Description:
Conveyor belt Monitor (FHT 3031-12 CCM)

Thermo Scientific™ FHT 3031 CCM Conveyor Belt Monitor quickly and reliably checks large quantities of material for possible contamination using the Cobalt Coincidence Method (CCM). It is ideal for refurbishing or dismantling older nuclear facilities to ascertain whether materials may be released as ordinary scrap or as waste.

  • Sensitive Co60 contamination measurement also in fluctuating Co60 dose rate fields
  • Spatially focused detection of Co60
  • Simultaneous gross gamma counting
  • Continuous sample throughput by means of conveyor drive
  • Assembly comprised of measuring portal with belt conveyor drive, plus two roll conveyors on each side to load and unload the samples
  • Assembly controlled by the FHT 8000 measuring electronics fitted with a multi coincidence logic for the detectors 1 to 6
  • The group of detectors 7 to 12 is coupled to a second electronic that is serially linked to the master electronics
  • No lead shielding necessary, therefore easily applicable
  • Easy-to-use Windows™ software for operation and report generation
  • Effective compensation of natural radioactivity
  • Tremendous improvement of the signal-to-background-ratio
  • Limit of detection as per ISO 11929, p1: 150 Bq in 40 sec for each of the CCM detector pairs at 5% probability of false alarm and not detected contamination, respectively
  • Signal-to-background-ratio s/b: s/b (CCM) >10 × s/b (Co-60 ROI) at 1000 Bq and 100 nSv/h ambient dose rate

Recommended for:

Refurbishing or dismantling older nuclear facilities

Specifications
TypeCCM Conveyor Belt Monitor
Relative Humidity20 to 80%, Non-condensing
DescriptionConveyor belt Monitor (FHT 3031-12 CCM)
Temperature (English) Operating59° to 104°F
Temperature (Metric) Operating15° to 40°C
Unit SizeEach