Thermo Scientific™

iCAP™ 7400 ICP-OES Analyzer

Catalog number: 842320074181
Thermo Scientific™

iCAP™ 7400 ICP-OES Analyzer

Catalog number: 842320074181

Enabling regulatory compliance for a wide range of trace element applications, the compact and robust Thermo Scientific™ iCAP™ 7400 ICP-OES delivers superb performance and productivity. With its broad analytical capabilities, this powerful instument is allowing full wavelength coverage while retaining high sensitivity. It requires minimal user set-up and maintenance, and has a low cost per sample. The iCAP 7400 ICP-OES is controlled with the integrated Thermo Scientific™ Qtegra™ Intelligent Scientific Data Solution™ (ISDS) software, which enables quick set-up and easy operation.

 
Catalog Number
842320074181
also known as 8423 200 74181
Unit Size
Each
Type
ICP-OES Duo
Price (EUR)
Full specifications
TypeICP-OES Duo
Detector TypeHigh performance solid-state CID86 chip
Peristaltic Pump4-channel, 12-roller
Data Acquisition ModesPrecision mode, Speed mode
Depth (Metric)750 mm
Full-frame CapabilityYes
Height (Metric)590 mm
IncludesIntelligent introduction and rinse, Speed data acquisition mode, Get ready: automatic performance checks
Spectral Bandpass7 pm at 200 nm
SpectrometerSimultaneous echelle type, 52.91 grooves/ mm ruled grating, 383 mm effective focal length, 9.5° UV fused silica cross dispersion prism
Standard Sampling KitConcentric glass nebulizer, Glass cyclonic spray chamber, Semi-demountable EMT torch, 1.5 mm bore quartz center tube (Radial), 2 mm bore quartz center tube (DUO)
Wavelength Range166 to 847 nm
Width (Metric)840 mm
Unit SizeEach
Catalog Number
842320074141
also known as 8423 200 74141
Unit Size
Each
Type
ICP-OES Radial
Price (EUR)
Full specifications
TypeICP-OES Radial
Detector TypeHigh performance solid-state CID86 chip
Peristaltic Pump4-channel, 12-roller
Data Acquisition ModesPrecision mode, Speed mode
Depth (Metric)750 mm
Full-frame CapabilityYes
Height (Metric)590 mm
IncludesIntelligent introduction and rinse, Speed data acquisition mode, Get ready: automatic performance checks
Spectral Bandpass7 pm at 200 nm
SpectrometerSimultaneous echelle type, 52.91 grooves/ mm ruled grating, 383 mm effective focal length, 9.5° UV fused silica cross dispersion prism
Standard Sampling KitConcentric glass nebulizer, Glass cyclonic spray chamber, Semi-demountable EMT torch, 1.5 mm bore quartz center tube (Radial), 2 mm bore quartz center tube (DUO)
Wavelength Range166 to 847 nm
Width (Metric)840 mm
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeTypePrice (EUR)
842320074181
also known as 8423 200 74181
Full specifications
EachICP-OES DuoRequest A Quote
TypeICP-OES Duo
Detector TypeHigh performance solid-state CID86 chip
Peristaltic Pump4-channel, 12-roller
Data Acquisition ModesPrecision mode, Speed mode
Depth (Metric)750 mm
Full-frame CapabilityYes
Height (Metric)590 mm
IncludesIntelligent introduction and rinse, Speed data acquisition mode, Get ready: automatic performance checks
Spectral Bandpass7 pm at 200 nm
SpectrometerSimultaneous echelle type, 52.91 grooves/ mm ruled grating, 383 mm effective focal length, 9.5° UV fused silica cross dispersion prism
Standard Sampling KitConcentric glass nebulizer, Glass cyclonic spray chamber, Semi-demountable EMT torch, 1.5 mm bore quartz center tube (Radial), 2 mm bore quartz center tube (DUO)
Wavelength Range166 to 847 nm
Width (Metric)840 mm
Unit SizeEach
842320074141
also known as 8423 200 74141
Full specifications
EachICP-OES RadialRequest A Quote
TypeICP-OES Radial
Detector TypeHigh performance solid-state CID86 chip
Peristaltic Pump4-channel, 12-roller
Data Acquisition ModesPrecision mode, Speed mode
Depth (Metric)750 mm
Full-frame CapabilityYes
Height (Metric)590 mm
IncludesIntelligent introduction and rinse, Speed data acquisition mode, Get ready: automatic performance checks
Spectral Bandpass7 pm at 200 nm
SpectrometerSimultaneous echelle type, 52.91 grooves/ mm ruled grating, 383 mm effective focal length, 9.5° UV fused silica cross dispersion prism
Standard Sampling KitConcentric glass nebulizer, Glass cyclonic spray chamber, Semi-demountable EMT torch, 1.5 mm bore quartz center tube (Radial), 2 mm bore quartz center tube (DUO)
Wavelength Range166 to 847 nm
Width (Metric)840 mm
Unit SizeEach
Showing 2 of 2

Inductively Coupled Plasma-Optical Emission Spectrometry (ICP-OES) is an established and powerful technique for the analysis and quantitation of trace elements in both liquid and solid samples.

The rugged and reliable iCAP 7400 ICP-OES is a powerful elemental analyzer with a small footprint. Other features and benefits of this spectrometer include the following:

Sampling System:
  • Suitable for mid-range sample throughputs.
  • 4-channel, 12-roller, peristaltic pump, with a unique drain sensor, provides smooth, low noise signals and safe operation.
  • Autosampler accessories allow analyzing of 180-720 liquid samples unattended.
  • Instrument speed mode enables analysis of larger sample loads.
  • Intelligently grouped wavelengths enhance data acquisition speed and increase sample throughput.
  • Integrated hydride generation system accessory provides sub-ppb detection of hydride-forming elements.
  • Optional sample handling kits available for organic/volatile solvent-based, hydrofluoric acid, and high solids solutions.

Versatility:
  • Handles a wide range of applications in a broad range of industries.
  • Supports QA/QC and contract laboratory workflows.
  • Supports automated and intelligent sample preparation.

Optical System:
  • High-efficiency light transmission and excellent resolution, sensitivity and detection.
  • A selection of wavelengths between 166–847nm and optimal signal-to-noise measurement.
  • Dedicated radial or duo plasma view configurations to suit different sample types and elements of interest.
  • Improved long-term signal stability using a mass flow-controlled nebulizer gas flow.
  • Customizable to a range of challenging matrices and sample volumes, extending your laboratory's capabilities.

Software:
  • Integrated Qtegra Intelligent Scientific Data Solution (ISDS) software minimizes task times and maximizes protocol automation.
  • Integrated Element Finder plug-in automates method development, optimizing plasma parameters and selecting wavelengths best suited to the sample.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text