Qubit™ Flex Fluorometer
Qubit™ Flex Fluorometer
Invitrogen™

Qubit™ Flex Fluorometer

The Qubit Flex Fluorometer is a benchtop fluorometer designed for highly accurate quantification of DNA, RNA, microRNA, and protein. WithRead more
Have Questions?
Catalog NumberQuantity
Q333271 fluorometer
Catalog number Q33327
Price (EUR)
7.880,00
Each
-
Add to cart
Quantity:
1 fluorometer
Price (EUR)
7.880,00
Each
Add to cart
Ask our AI about this Product
The Qubit Flex Fluorometer is a benchtop fluorometer designed for highly accurate quantification of DNA, RNA, microRNA, and protein. With the Qubit Flex Fluorometer you have the flexibility to directly measure fluorescence of up to eight samples simultaneously, which reduces assay variability. Paired with Qubit reagents, the Qubit Flex Fluorometer is part of an optimized workflow generating highly accurate and reproducible results. The fluorometer has a large screen and intuitive user interface, making it easy to select and run your desired assay with results displayed in just a few seconds.

Features of the Qubit Flex Fluorometer include:
Improved throughput—measure multiple samples and quantify DNA, RNA, and protein up to 50% faster than single-sample readers
Flexibility—measure up to eight samples simultaneously
Complete optimized system—works seamlessly with Qubit reagents to generate reliable, sensitive, and specific results
Accurate quantification—high levels of accuracy using only 1–20 μL of sample, even with very dilute samples
On-board calculators—quickly generates Qubit working solution preparation instructions and determines the molarity of your samples
Easy to use—a large 8-inch, state-of-the-art color touchscreen and intuitive user interface results in easy workflow navigation
Data export flexibility—data is transferred easily using the included WiFi dongle, a USB drive, or directly to your computer
Several languages available—choices include English, French, Spanish, Italian, German, simplified Chinese, and Japanese
Verification test—a pre-loaded program is included to verify performance of the instrument
Qubit Flex SmartStart Digital Educational Experience—includes interactive visual demonstrations of how to install, operate, and maintain your instrument
Three-year Extended Warranty—if your instrument needs repair we will send you a factory-certified refurbished replacement

Higher throughput, less variability than single sample readers
The Qubit Flex Fluorometer has the flexibility to measure multiple DNA, RNA, and protein samples up to 50% faster than single-sample readers. In addition to saving time, the ability to measure eight samples simultaneously reduces variability, resulting in highly reproducible data. The Qubit Flex Fluorometer includes Reagent, Range, and Molarity calculators, further reducing the time to results. The Reagent and Range calculators help to determine which reagent and amount of sample to use to effectively quantify the amount of DNA, RNA, or protein. The Molarity calculator allows you to calculate the molarity of your samples based on nucleic acid length and the measured concentration.

Enables more accurate results than UV absorbance at low concentrations
The Qubit Flex Fluorometer is far more sensitive than UV absorbance, which measures anything absorbing at 260 nm, including DNA, RNA, protein, free nucleotides, and excess salts. Moreover, UV spectrophotometry is often not sensitive enough to accurately measure low concentrations of DNA and RNA. With the Qubit Flex fluorometer, your research is enhanced by more accurate measurements because the dyes in the Qubit assay kits fluoresce only when bound to the target molecule (DNA, RNA, or protein) in your sample. This allows you to avoid repeating work due to inaccurate measurements.

Optimized solution consisting of instrument and reagents results in highly reproducible data
The thoughtfully designed Qubit Flex Fluorometer requires sample volumes of only 1–20 μL. The advanced optics and data analysis algorithms were designed and optimized to work in perfect harmony with Qubit reagents, resulting in a seamless solution that generates highly reliable, sensitive, and specific results.
For Research Use Only. Not for use in diagnostic procedures.
Specifications
For Use With (Application)DNA Quantification, RNA Quantification, MicroRNA Quantification, Protein Quantification
IncludesQubit™ Flex Fluorometer, Qubit™ Flex Power Cord, Wi-Fi Dongle
Quantity1 fluorometer
Sample Volume1 to 20 μL
Shipping ConditionRoom Temperature
Excitation Wavelength460 to 480 nm (Blue LED), 620 to 640 nm (Red LED)
Product LineQubit
TypeFluorometer
Unit SizeEach

Enhance your Qubit Fluorometer with the latest firmware

New Qubit 4 and Qubit Flex firmware features include importing sample IDs, renaming files before exporting, a countdown timer, and on-board troubleshooting guidance. Get the most out of your Qubit assays with these powerful new tools.

Download the latest Qubit firmware ›

Have questions about this product? Ask our AI assisted search.
This is an AI-powered search and may not always get things right. You can help us make it better with a thumbs up or down on individual answers or by selecting the “Give feedback" button. Your search history and customer login information may be retained by Thermo Fisher and processed in accordance with our Privacy Notice.

Frequently asked questions (FAQs)

Can the Qubit 1X dsDNA, broad range (BR) Assay Kit (Cat. No. Q33265) be used on the Qubit 3 Fluorometer?

No, this assay is only compatible with Qubit 4 Fluorometer (Cat. No. Q33226) and Qubit Flex Fluorometer (Cat. No. Q33327).

Find additional tips, troubleshooting help, and resources within our Nucleic Acid Quantification Support Center.

When setting up standard measurements using the Qubit Flex Fluorometer, should I add the standard+reagent mix to all 8 tubes or just one?

You have the flexibility to run less than 8 standards on the Qubit Flex Fluorometer. However, you can only place samples into the wells that have been calibrated. For instance, if you run standards in 6 wells, you can only run samples in those 6 wells (or fewer).

Find additional tips, troubleshooting help, and resources within our Nucleic Acid Quantification Support Center.

My Qubit Flex Fluorometer (Cat. No. Q33327) cannot detect the WiFi dongle. How can I resolve this?

This issue can be a result of the REV C Wifi dongle being incompatible with firmware versions before 1.6.0. Please check that you are on firmware version 1.6.0 or later.

If the issue persists, please contact Technical Support at techsupport@thermofisher.com.

Can I use the Qubit Endotoxin Detection Assay Kit on the Qubit 4 Fluorometer?

No, the Qubit Endotoxin Detection Assay Kit is designed for use with the Qubit Flex Fluorometer and is not currently for use on the Qubit 4 Fluorometer.

To use the Qubit Endotoxin Detection Assay Kit on the Qubit Flex Fluorometer, do I need to perform a software update ?

Yes, the endotoxin detection assay program will be available on Qubit Flex Software version 1.8.0 or later. The latest software is available under the Resources section of www.thermofisher.com/qubit

Documents & Downloads

Certificates

Safety Data Sheets

Share catalog number, name or link

1x1 image pixel for data collection