VEGF Human ELISA Standard
Product Image
Invitrogen™

VEGF Human ELISA Standard

This human VEGF standard is suggested for use with Thermo Scientific Human VEGF ELISA Kits. Prepare standards within one hourMás información
Have Questions?
Número de catálogoCantidad
SVEGF1 Vial
Número de catálogo SVEGF
Precio (EUR)
127,00
1 vial
Añadir al carro de la compra
Cantidad:
1 Vial
Precio (EUR)
127,00
1 vial
Añadir al carro de la compra
Ask our AI about this Product
This human VEGF standard is suggested for use with Thermo Scientific Human VEGF ELISA Kits. Prepare standards within one hour of use, and do not store reconstituted standards for prolonged periods.

• Suggested concentration of top standard is 2000 pg/mL
• Standards should be reconstituted and diluted in Reagent Diluent (provided in kit)
For Research Use Only. Not for use in diagnostic procedures.
Especificaciones
Para utilizar con (equipo)Lector de microplacas
Identificadores anterioresPierce
génicavascular endothelial growth factor A
Alias de genMVCD1, VEGF, VPF
ID de gen (Entrez)7422
Símbolo de genVEGFA
Expresiónvascular endothelial growth factor A
Alias de proteínaVEGF-A, Vascular permeability factor, VPF
Familia de proteínasGrowth Factors & Receptors
Cantidad1 Vial
Nombre del kit de destinoVEGF
Especies diana validadasHumano
ID. de UniProtP15692
Formato del kit de inmunoensayoELISA (Standard)
Especies dianaHuman
Unit Size1 vial
Contenido y almacenamiento
Store below -20°C.
Have questions about this product? Ask our AI assisted search.
This is an AI-powered search and may not always get things right. You can help us make it better with a thumbs up or down on individual answers or by selecting the “Give feedback" button. Your search history and customer login information may be retained by Thermo Fisher and processed in accordance with our Privacy Notice.

Figuras

Documentos y descargas

Certificados

N.º de loteCertificate TypeDateCatalog Number(s)
PJ210951Certificate of Analysis16 abr 2017SVEGF
PJ210586Certificate of Analysis16 abr 2017SVEGF
PK211509Certificate of Analysis16 abr 2017SVEGF
PK211509ACertificate of Analysis16 abr 2017SVEGF
Se muestran 4 resultados, busque arriba un certificado específico

Hojas de datos de seguridad

Preguntas frecuentes

All ELISA kits are provided in the sandwich ELISA format with capture antibody already coated onto a 96 well plate. Typical detection uses a biotinylated detection antibody followed by Streptavidin-HRP and HRP substrate. Most kits are available as single 96-well plate kits, some are available as 2- and 5-plate kits. Kits typically contain:

96 Well Strip Plate coated with capture antibody
Standard protein
Wash buffer, 10x
ELISA buffer/Diluent, 10x
Detection antibody (in most kits, biotinylated)
HRP Reagent (either secondary antibody or streptavidin conjugated to HRP)(100x)
Substrate (usually TMB)
Stop solution
Adhesive plate covers

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.

Running internal controls along with the blanks and the standard curve is an excellent way to monitor the performance of any ELISA kit. Internal controls are samples containing known amounts of the analyte being measured with the kit. A key attribute of internal controls, and what differentiates them from the samples of the standard curve, is that they duplicate the composition of your actual samples as closely as possible. This is important because your samples may contain components that affect detection of the analyte differently than does the Standard Diluent provided in the kit. In other words, internal controls allow you to determine if assaying the same amount of analyte in the Standard Diluent (the standard curve) and in the sample matrix (internal controls) gives the same results. It's also important to remember that internal controls give you confidence in the accuracy of your results. Internal controls help ensure that the assay is performing consistently from assay to assay, every time you run it.

One source of internal controls is naturally occurring samples (such as serum or plasma) containing known amounts of the analyte you want to measure. Such positive control samples can be run as-is, or they can be diluted to various known concentrations, preferably with a naturally occurring negative sample of the same type. It's a good idea to run at least 2 internal controls, if you can. One usually has an analyte concentration between the lowest point on the standard curve and the curve's midpoint, while the other has a concentration between the midpoint and the highest concentration. Some researchers also run an internal control that falls close to the midpoint of the curve.

If you don't have access to naturally occurring controls, you can prepare them yourself. Let's say that you will be measuring interleukin-6 (IL-6) in human serum samples with an ELISA kit, Cat. No. KHC0061. First you will need to obtain some pooled normal human sera, which will be used as the sample matrix for your internal controls. Preferably, the IL-6 content of this serum should be negligible (but known) or too low to measure. Next you should add known amounts of human IL-6 to this serum to create the internal controls, using the human IL-6 standard provided in the kit. After you prepare the standard curve as described in the product manual, add some of the leftover concentrated IL-6 standard to the serum matrix. As described above, you can prepare controls with high and low IL-6 levels, or high, medium, and low, if you have enough wells in your ELISA plate.

Even if your sample type is not serum and you're not measuring IL-6, follow the general procedure outlined above to prepare your internal controls with your protein and sample matrix of interest. A valuable resource describing Spike and Recovery and Linearity of Dilution assays can be found here (http://tools.thermofisher.com/content/sfs/brochures/TR0058-Spike-and-Recovery.pdf). If you need more help, please contact Technical Support at techsupport@thermofisher.com.

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.

Our ELISA kits can be categorized into several different groups (see Table 2, Page 35 of the Protein Analysis Handbook - http://www.thermofisher.com/us/en/home/global/forms/protein-handbook-registration.html), based on a number of factors: target protein class, sensitivity, readout method, or ability to detect specific phosphorylation states of the target protein.

Standard colorimetric ELISA kits use a standard colorimetric readout and allow excellent sensitivity and detection range. Typical sensitivity is less than 10 pg/mL and standard curve range is around 10-250 pg/mL, although there are some kits with wider ranges.
Ultrasensitive ELISA kits use a standard colorimetric readout but enable detection and analysis of proteins to levels as low as 0.5 pg/mL. With measurement range of 0.5-20 pg/mL, these kits are especially useful with highly diluted samples.
Chemi ELISA kits use chemiluminescence detection for high sensitivity (less than 1 pg/mL) and are highly flexible with a wide measurement range from 0.5 to 2000 pg/mL.
Phospho ELISA kits enable the specific detection of phosphorylation of key signaling proteins with high specificity, and are often used to supplement western blot results and provide quantitative data.

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.

We offer full ELISA kits, Reagent Sets and Antibody Pairs. ELISA kits are complete, ready-to-use kits with pre-coated plates, all buffers, capture, and detection antibodies included. Most kits are single plate format, but some are available in 2- or 5-plate formats. Reagent Sets are for researchers who need the core kit components but prefer to make their own buffers and coat their own plates. Antibody Pairs are matched pairs of detection and capture antibodies for researchers who need to process large numbers of samples.

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.

Compartir número de catálogo, nombre o enlace.

1x1 image pixel for data collection