Orion™ 2117XP Chloride Analyzer
Orion™ 2117XP Chloride Analyzer
Le produit réel peut varier
Thermo Scientific™

Orion™ 2117XP Chloride Analyzer

Detect chloride in real time with accurate and reliable results using the Thermo Scientific™ Orion™ 2117XP Chloride Analyzer.
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceDescription
2117XPG2117XP Chloride Analyzer With Grab Smapler
2117XP2117XP Chloride Analyzer
2117XPEN2117XP Chloride Analyzer With Enclosure
2117XPENG2117XP Chloride Analyzer With Enclosure and Grab Smapler
4 options
Référence 2117XPG
Prix (EUR)/ Each
-
Demander un devis
Description:
2117XP Chloride Analyzer With Grab Smapler
Detect chloride in real time with accurate and reliable results using the Thermo Scientific™ Orion™ 2117XP Chloride Analyzer. Early detection of chloride ingress from feedwater helps your plant maintain the optimal balance of water purification and peace of mind.
Features:
  • Detection limit of 0.1ppm offers continuous chloride monitoring in wide variety of samples.
  • Protection against early breakthrough with sensitive, selective, reliable and verfiable measurements provides early detection of chloride in RO and boiler systems.
  • Fast and highly accurate calibration has you back online in minutes.
  • System holds calibration up to 60 days between reagent changes.
  • Long life solid state sensor technology offers stability and high performance.
  • Simple operation and no moving parts means only minimal maintenance is required.
  • Get repeatable and verifiable measurements at a glance using the large, user-friendly display.

2117XP Chloride Analyzer Ordering Information:

  • Annual Consumables Kit, Cat. No. 211750XP
  • Reagent, Cat. No. 182011
  • Diffusion Tubing, Cat. No. 181060
  • Calibration Kit, Cat. No. 2117XPCAL
  • Calibration Standards, Cat. No. 211740
  • Chloride Electrode, Cat. No. 100025
  • Reference Electrode, Cat. No. 100057
  • Reference Electrode Filling Solution, Cat. No. 100057F4
Spécifications
Précision±10% or 0.1 ppm, whichever is greater
Précision (mV)± (0.5 mV + 0.1%)
Précision (température)±0.5°C
Sorties d’alarme3
Sorties analogiques2, Galvanically Isolated
ÉtalonnageDouble Known Addition
Matériau du coffretValox 364
Certifications/ConformitéCE, CSA, UL, FCC Class A limits
Canaux1
Détails de la communicationModbus with Additional Module
Boucles de courant2
Description2117XP Chloride Analyzer With Grab Smapler
Limites de détection0.1ppm
Température (métrique) en fonctionnement5°C to 35°C
TypeChloride Analyzer
Type d’affichageCustom backlit LCD with temperature, concentration, mV, error codes and menu driven prompts
Classification du boîtierWaterproof; IP66; NEMA 4X
Débit40mL/min.
Comprend2117XP chloride analyzer with grab sampler, chloride electrode, reference electrode, ATC probe, chloride calibration standards kit, CD user guide and options kit
Pression d’arrivée8 to 100psig
Type de clavierMembrane
Humidité relative max.5 to 95%, non-condensing
Plages de mesure0 to 10ppm
Options de montageWall mount
Sorties0 to 20 mA; 4 to 20 mA
Détails des relais3 Relay Outputs; Relay Load: 250VAC; 30VDC; 5A
Temps de réponse95% within 2 minutes of injecting a standard solution
Débit d’échantillon40 mL/min nominal set by pressure regulator
Entrée des échantillons1/4 in. NPTF tube fitting
Flux d’échantillons1
Dimensions (L x l x H)11 x 17 x 26 in. (27 x 45 x 65cm)
Longueur (impériale)11 in.
Longueur (métrique)27 cm
Largeur (impériale)17 in.
Largeur (métrique)45 cm
Hauteur (impériale)26 in.
Hauteur (métrique)65 cm
Tension85 to 132 VAC; 170 to 264 VAC
Ampérage5A
Fréquence0 to 60 Hz
Channel 1Chloride
Channel 2Optional ph/ORP or Conductivity
Unit SizeEach