Colonne préemballé POROS™ GoPure™ 50 HQ, 0,5 x 5 cm, 1 ml
Colonne préemballé POROS™ GoPure™ 50 HQ, 0,5 x 5 cm, 1 ml
Thermo Scientific™

Colonne préemballé POROS™ GoPure™ 50 HQ, 0,5 x 5 cm, 1 ml

Thermo Scientific™ POROS™ GoPure™ 0.5 cm pre-packed columns are intended for the screening of POROS ion exchange resins or for small scale purification.
Have Questions?
RéférenceQuantité
44813151 colonne
Référence 4481315
Prix (EUR)
139,00
Each
Ajouter au panier
Quantité:
1 colonne
Prix (EUR)
139,00
Each
Ajouter au panier

POROS GoPure 0.5 cm pre-packed columns are intended for the screening of POROS ion exchange resins or for small scale purification.

Ces colonnes préemballées sont prêtes à être connectées et présentent les caractéristiques suivantes :

  • Dimensions de 0,5 x 5 cm, avec un volume de lit nominale de 1 ml, fournissant une plateforme de sélection uniforme
  • Connexion directe aux systèmes de chromatographie standard
  • Emballées avec des résines à haute performance POROS qui offrent une capacité de liaison dynamique élevée et une haute résolution sur une large gamme de débits

La résine de cette colonne POROS GoPure ™ HQ 50 μm possède un groupe fonctionnel de polyéthylèneimine quaternisé pour une chromatographie d’échange d’anions forte.

  • Pratique — Des colonnes prêtes à l’emploi qui simplifient et accélèrent l’évaluation des résines POROS
  • Conservation de l’échantillon — Le volume nominal du lit de 1 ml minimise les besoins en échantillons pour la sélection de plusieurs résines
  • Évolutivité simplifiée — L’uniformité et la variété de la famille POROS GoPure de colonnes préemballées simplifient la mise à l’échelle et la modélisation des procédés

Les colonnes préemballées POROS GoPure de 0,5 cm ont été développées pour répondre aux besoins des chercheurs en développement de procédés nécessitant une plateforme de sélection des résines POROS pratique et uniforme. Le volume de lit de 1 ml réduit les besoins en échantillons, et le temps de séjour recommandé de ≥3 minutes (0,3 ml/min) sur cette colonne de 5 cm de longueur équivaut à 400 cm/h sur un lit de 20 cm de hauteur. Des spécifications détaillées peuvent être trouvées dans le mode d’emploi des colonnes POROS GoPure de 0,5 cm ci-dessous.

D’autres résines échangeuses d’anions POROS, ainsi que des résines échangeuses de cations, sont également disponibles dans ce format de colonne. Toutes les résines de chromatographie à haute performance POROS™ présentent une structure unique des pores qui assure un excellent transport de masse pour une capacité et une résolution élevées sur une large gamme de débits.

Pour la mise à l’échelle, les colonnes préemballées POROS GoPure sont disponibles dans une gamme de diamètres et dans plusieurs hauteurs de lit qui correspondent à une plage de volume de colonne allant de 5 ml à 6,3 litres.

Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.
Spécifications
Type de colonneÉchange d’anions
À utiliser avecFPLC
Compatibilité à haut débitProtocoles automatisés
Pression max.30 bars
Quantité1 colonne
Type d’échantillonÉchantillon de purification biopharmaceutique, surnageants de culture cellulaire, sérum
Phase stationnairePolyéthylèneimine quaternisée
Volume (métrique)1 mL
Diamètre (métrique)0.5 cm
Longueur (métrique)5 cm
Granulométrie50 μm
Gamme de produitsGoPure
Unit SizeEach
Contenu et stockage
Expédié dans 20 % d’éthanol entre 2 °C et 30 °C.

Foire aux questions (FAQ)

Are POROS analytical columns compatible with HPLC systems from Waters or Agilent?

All of the pre-packed POROS columns, regardless of column size or resin, have the same 10-32 female fittings on the column. Columns are compatible with Waters and Agilent HPLC systems. You will need 1/16 inch male fittings for the HPLC to attach the column.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.

For any POROS analytical column, is the column compatible with an AKTA or Avant purification system?

All of the pre-packed columns, regardless column size or resin, have the same 10-32 female fittings on the column. They are all compatible with the AKTA instrument platform, however due to the column volume of the 2.1 mmD x 30 mmL columns (0.1 mL), these will not perform well in AKTA or Avant purification systems due to the relative size of the hold- up volume in these systems. The smallest column (PEEK or SS) that could feasibly be used in these systems is the 4.6mmD x 50mmL (0.8 mL) format.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.

Are the pre-packed POROS CaptureSelect or any POROS analytical columns compatible with an UPLC or is the use of these columns limited to HPLC?

UPLC is typically described as chromatography with sub-2 µm particles, which drives higher efficiency/better separation independent of operating flow rate. As particle size decreases, backpressure increases so the UPLC systems tend to have higher pressure ratings compared to HPLC systems. The flow rates on UPLC systems would be sufficient for POROS columns. Pump capabilities are typically 0.1-1.0 mL/min, so not as fast as a HPLC, but sufficient. Hold-up volumes on UPLC systems are lower than HPLCs, so this can help with sensitivity and efficiency. So from a pressure and flow standpoint there should be no challenge to operate a POROS CaptureSelect column on a UPLC system.

That being said, care should be taken running POROS columns on UPLC systems. Higher pressure safety interlock MUST be set at the rated column pressure, typically 180 bar. HPLC column hardware is not rated to operate at the static pressures possible and typical on UPLC systems. A clog or the like on a UPLC system could generate unsafe pressures on any HPLC-rated column before the default UPLC safety pressure interlock is tripped.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.

What is the physical or mechanical stability of POROS resins?

The physical stability of POROS resins is high. Customers have agitated, with overhead mixing and or bottom gassing for long periods of time (5-10 hours) and have performed hundreds of diaphragm pump passes during stall packs. Keep in mind that agitation with any device that creates grinding and sheer, such as with a magnetic stir bar, is not recommended for any type of resin.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.

What should I do if a POROS column dries out or air is pumped onto the column?

POROS resins rehydrate quite well. Here is the procedure that we recommend:

1. Flow 5% ethanol over the column at ?350 cm/hour for 3 CVs, followed by water or 0.1 M sodium chloride at 300 cm/hour for 3 CVs.
2. If baseline noise is still present, flow 20% ethanol over the column at 300 cm/hour for 3 CVs, followed by water or 0.1 M sodium chloride at 300 cm/hour for 3 CVs.
3. If you have established column qualification tests and specifications, perform the tests after rewetting.

Find additional tips, troubleshooting help, and resources within our Protein Purification and Isolation Support Center.