Perform routine continuous measurement of contaminants including water and oxygen to single-digit ppt levels with Thermo Scientific™ APIX/APIMS δQ and APIX/APIMS Quattro Ultra High Purity (UHP) Electronic Gas Analyzers.

These gas analyzers offer a cost effective alternative to conventional quality control techniques allowing each bulk gas to be monitored for a range of potential contaminants, while achieving lower detection limits (up to 100 times better) than any technology.
 
產品號碼
APIMSXANLYZ
Unit Size
Each
Product Type
Ultra High Purity Gas Analyzer
價格 (HKD)
完整規格
Product TypeUltra High Purity Gas Analyzer
Detection Limits<10 ppt (component dependent)
Detector TypePulse Counting Channel Electron Multiplier
Ion Source TypeAtmospheric Pressure Ionization
Analysis TimeCycle time 2 minutes
Bulk Gas SuitabilityH2, N2, Ar, He (plus O2 for dB model)
DescriptionElectronic gas analyzer
Detection Noise100 MHz (pulse counting type)
Hertz100 MHz (pulse counting type)
Impurities MonitoredH2, CH4, H2O, CO, N2, O2, Ar, CO2, Kr and Xe (depending on bulk gas)
Ion Source Background<1ppt
Measurement MethodAPIMS dB: 1x Triple filter; APIMS Quattro: 4x Triple filter
Serial ConnectionsRS232 Serial Port
Unit SizeEach
顯示 1 項,共 1 項
產品號碼規格Unit SizeProduct Type價格 (HKD)
APIMSXANLYZ完整規格
EachUltra High Purity Gas Analyzer申請報價
Product TypeUltra High Purity Gas Analyzer
Detection Limits<10 ppt (component dependent)
Detector TypePulse Counting Channel Electron Multiplier
Ion Source TypeAtmospheric Pressure Ionization
Analysis TimeCycle time 2 minutes
Bulk Gas SuitabilityH2, N2, Ar, He (plus O2 for dB model)
DescriptionElectronic gas analyzer
Detection Noise100 MHz (pulse counting type)
Hertz100 MHz (pulse counting type)
Impurities MonitoredH2, CH4, H2O, CO, N2, O2, Ar, CO2, Kr and Xe (depending on bulk gas)
Ion Source Background<1ppt
Measurement MethodAPIMS dB: 1x Triple filter; APIMS Quattro: 4x Triple filter
Serial ConnectionsRS232 Serial Port
Unit SizeEach
顯示 1 項,共 1 項
  • Reliable, fully automatic system for online quality control
  • Superior sensitivity with lower detection capability of <10 ppt
  • Automatic switching and calibration
  • Fast online measurement (typically <5 seconds for complete analysis)
  • Industry standard communications protocol for plant control and integration


Recommended for:

  • UHP Nitrogen
  • UHP Argon
  • UHP Helium
  • UHP Hydrogen

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text