Thermo Scientific™

Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer

產品號碼: IQLAAEGAAPFALGMBDK
Thermo Scientific™

Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer

產品號碼: IQLAAEGAAPFALGMBDK

Take Quanfirmation™ to the next level. The Thermo Scientific™ Q Exactive™ Hybrid Quadrupole-Orbitrap™ Mass Spectrometer introduced the revolutionary concept of Quanfirmation. The Q Exactive™ Plus Hybrid Quadrupole-Orbitrap™ Mass Spectrometer takes Quanfirmation to the next level with increased performance and new options that enhance applications from confident DMPK qual/quan screening studies to characterization of intact monoclonal antibodies.

 
產品號碼
IQLAAEGAAPFALGMBDK
Unit Size
Each
Scan Rates
Up to 12 Hz
Mass Range
50 to 6000 m/z
價格 (HKD)
完整規格
TypeQuadrupole-Orbitrap LC-MS
Dynamic Range>5000:1
Mass Range50 to 6000 m/z
Mass AccuracyInternal: <1 ppm RMS
External: <3 ppm RMS
Scan RatesUp to 12 Hz
Polarity SwitchingOne Full Cycle in <1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 35,000))
SensitivityFull MS: 500 fg Buspirone on Column S/N 100:1
SIM: 30 fg Buspirone on Column S/N 100:1
Max. ResolutionUp to 240,000 at m/z 200
Unit SizeEach
顯示 1 項,共 1 項
產品號碼規格Unit SizeScan RatesMass Range價格 (HKD)
IQLAAEGAAPFALGMBDK完整規格
EachUp to 12 Hz50 to 6000 m/z申請報價
TypeQuadrupole-Orbitrap LC-MS
Dynamic Range>5000:1
Mass Range50 to 6000 m/z
Mass AccuracyInternal: <1 ppm RMS
External: <3 ppm RMS
Scan RatesUp to 12 Hz
Polarity SwitchingOne Full Cycle in <1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 35,000))
SensitivityFull MS: 500 fg Buspirone on Column S/N 100:1
SIM: 30 fg Buspirone on Column S/N 100:1
Max. ResolutionUp to 240,000 at m/z 200
Unit SizeEach
顯示 1 項,共 1 項

Superior Quantitation

  • Advanced quadrupole technology (AQT) improves precursor selection and transmission for more-accurate quantitation of low-abundance analytes in complex matrices
  • Sophisticated data-independent acquisition (DIA) and parallel reaction monitoring (PRM) deliver reproducible quantitation with complete qualitative confidence
  • An advanced active beam guide (AABG) reduces noise and extends maintenance intervals

Enhanced Analysis of Intact Proteins

  • Optional intact protein mode provides superior trapping of large molecules for improved analysis of intact proteins and protein complexes
  • Optional enhanced resolution ensures maximum ID confidence in top-down proteomics and lipidomics

High-Confidence Results

  • HR/AM and full-scan capabilities capture all sample data, all of the time, enabling retrospective data analysis without need to re-run samples
  • Resolving power up to 140,000 FWHM eliminates isobaric interferences, increasing confidence in results when analyzing samples in complex matrices
  • Better than 1-ppm mass accuracy in full- and all-ion fragmentation (AIF) scan modes ensures confident compound identification
  • Fast scanning at 12 Hz and spectral multiplexing suited to UHPLC applications
  • Rapid polarity switching maximizes information obtained
  • AIF and multiple dissociation techniques — in-source CID and HCD — aid in compound identification
  • Mass range to 6000 m/z enhances detection of singly charged small molecules and biomolecules
  • More than four orders of magnitude intrascan dynamic range, along with femtogram-level sensitivity, allow detection of trace-level and high-abundance compounds in the same scan

For Research Use Only. Not for use in diagnostic procedures.

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text