Thermo Scientific™

Sensititre™ YeastOne™ YO9 AST Plate

產品號碼: YO9
Thermo Scientific™

Sensititre™ YeastOne™ YO9 AST Plate

產品號碼: YO9

Simplify yeast susceptibility testing with the Thermo Scientific™ Sensititre™ YeastOne™ YO9 AST Plate with nine antifungals, including Amphotericin B and Micafungin. The Sensititre™ YeastOne™ YO9 AST Plate is intended for research use only.

Colorimetric Thermo Scientific™ alamarBlue™ agent provides reliable, easy and consistent endpoint determination with visual read option for efficient workflow and accurate results.

 
產品號碼
YO9
Unit Size
Each
Description
Sensititre YeastOne Research Use Only Plate, w/ Anidulafungin and Micafungin
Quantity
10/Pk.
價格 (HKD)
完整規格
0.5 McFarland StandardH2O (Part No. T3339)
SpeciesCandida species
Antimicrobial AgentsVarious
Broth TypeYeastOne Broth (Part No. Y3462)
DescriptionSensititre YeastOne Research Use Only Plate, w/ Anidulafungin and Micafungin
Antibiotic CodeVarious
Product TypeMicrobiology Media
Test TypeYeast Susceptibility
Incubation Conditions35°C O2
Incubation Time24-25 hr or 48-72 hr for Cryptococcus* (*For research use only. Not for use in diagnostic procedures.)
Isolates Per Plate1
No. per Pack10
Quantity10/Pk.
Reading OptionsManual
Transfer Volume20µL
Volume Per Well100 μL
Unit SizeEach
顯示 1 項,共 1 項
產品號碼規格Unit SizeDescriptionQuantity價格 (HKD)
YO9完整規格
EachSensititre YeastOne Research Use Only Plate, w/ Anidulafungin and Micafungin10/Pk.申請報價
0.5 McFarland StandardH2O (Part No. T3339)
SpeciesCandida species
Antimicrobial AgentsVarious
Broth TypeYeastOne Broth (Part No. Y3462)
DescriptionSensititre YeastOne Research Use Only Plate, w/ Anidulafungin and Micafungin
Antibiotic CodeVarious
Product TypeMicrobiology Media
Test TypeYeast Susceptibility
Incubation Conditions35°C O2
Incubation Time24-25 hr or 48-72 hr for Cryptococcus* (*For research use only. Not for use in diagnostic procedures.)
Isolates Per Plate1
No. per Pack10
Quantity10/Pk.
Reading OptionsManual
Transfer Volume20µL
Volume Per Well100 μL
Unit SizeEach
顯示 1 項,共 1 項

Achieve reliable, consistent results for Candida species with the Sensititre YeastOne YO9 AST Plate.

  • Room-temperature storage eliminates inventory control concerns
  • Individual packaging allows laboratory to test one plate at a time with no waste
  • Inclusive on-scale QC ranges provide immediate quality assurance of testing methodology
  • 24-hour incubation time enables timely results for clinicians

Not all products are available for sale in all territories. Please inquire.

VersaTREK™ and Sensititre™ products are now part of the Thermo Scientific brand.

For Research Use Only. Not for use in diagnostic procedures.