Thermo Scientific™

ConservatIR™ FTIR External Reflection Accessory

Catalog number: 869-188700
Thermo Scientific™

ConservatIR™ FTIR External Reflection Accessory

Catalog number: 869-188700
Easily perform spectral analysis on large objects, artwork, and paintings using the Thermo Scientific™ ConservatIR™ FTIR External Reflection Accessory. This accessory measures samples too large to fit into a Thermo Scientific™ Nicolet™ FTIR Spectrometer sample compartment. The articulated arm simplifies sample analysis for specular, diffuse and ATR measurements with the object in front, below or above the spectrometer sample compartment. The ConservatIR accessory comes standard with a specular/diffuse reflection sampling head, and a diamond ATR sampling head is available as an option.
 
Catalog Number
869-188700
Unit Size
Each
Description
ConservatIR FTIR External Reflection Accessory
For Use With (Equipment)
Nicolet iS5 FTIR Spectrometers
Angle
-5° to + 95°
Price (JPY)
Availability
***
Full specifications
Angle-5° to + 95°
Crystal TypeDiamond ATR (optional)
For Use With (Equipment)Nicolet iS5 FTIR Spectrometers
Spectral RangeMid-IR
TypeExternal Reflection Accessory
DescriptionConservatIR FTIR External Reflection Accessory
For Use With (Application)Art conservation, art restoration, art authentication, large sample analysis, automotive
Height (Metric)533 mm
Length (Metric)653 mm
Sampling AreaReflectance Mode Spot Size ∼1.25 mm diameter; ATR Mode Spot Size ∼ 0.5 mm
Width (Metric)622 mm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
ConservatIR FTIR External Reflection Accessory
For Use With (Equipment)
Nicolet iS10 FTIR Spectrometers
Angle
-5° to + 95°
Price (JPY)
Availability
***
Full specifications
Angle-5° to + 95°
Crystal TypeDiamond ATR (optional)
For Use With (Equipment)Nicolet iS10 FTIR Spectrometers
Spectral RangeMid-IR
TypeExternal Reflection Accessory
DescriptionConservatIR FTIR External Reflection Accessory
For Use With (Application)Art conservation, art restoration, art authentication, large sample analysis, automotive
Height (Metric)533 mm
Length (Metric)653 mm
Sampling AreaReflectance Mode Spot Size ∼ 1.25 mm diameter; ATR Mode Spot Size ∼ 0.5 mm
Width (Metric)622 mm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
ConservatIR ATR Sampling Interface
For Use With (Equipment)
ConservatIR FTIR External Reflection Accessory
Angle
45°
Price (JPY)
Availability
***
Full specifications
Angle45°
Crystal TypeDiamond ATR (optional)
For Use With (Equipment)ConservatIR FTIR External Reflection Accessory
Spectral RangeMid-IR
TypeATR Sampling Head
DescriptionConservatIR ATR Sampling Interface
For Use With (Application)Art conservation, art restoration, art authentication, large sample analysis, automotive
Sampling AreaATR Mode Spot Size ∼ 0.5 mm
Unit SizeEach
Showing 3 of 3
Catalog NumberSpecificationsUnit SizeDescriptionFor Use With (Equipment)AnglePrice (JPY)Availability
869-188700Full specifications
EachConservatIR FTIR External Reflection AccessoryNicolet iS5 FTIR Spectrometers-5° to + 95°Request A Quote***
Angle-5° to + 95°
Crystal TypeDiamond ATR (optional)
For Use With (Equipment)Nicolet iS5 FTIR Spectrometers
Spectral RangeMid-IR
TypeExternal Reflection Accessory
DescriptionConservatIR FTIR External Reflection Accessory
For Use With (Application)Art conservation, art restoration, art authentication, large sample analysis, automotive
Height (Metric)533 mm
Length (Metric)653 mm
Sampling AreaReflectance Mode Spot Size ∼1.25 mm diameter; ATR Mode Spot Size ∼ 0.5 mm
Width (Metric)622 mm
Unit SizeEach
869-188800Full specifications
EachConservatIR FTIR External Reflection AccessoryNicolet iS10 FTIR Spectrometers-5° to + 95°Request A Quote***
Angle-5° to + 95°
Crystal TypeDiamond ATR (optional)
For Use With (Equipment)Nicolet iS10 FTIR Spectrometers
Spectral RangeMid-IR
TypeExternal Reflection Accessory
DescriptionConservatIR FTIR External Reflection Accessory
For Use With (Application)Art conservation, art restoration, art authentication, large sample analysis, automotive
Height (Metric)533 mm
Length (Metric)653 mm
Sampling AreaReflectance Mode Spot Size ∼ 1.25 mm diameter; ATR Mode Spot Size ∼ 0.5 mm
Width (Metric)622 mm
Unit SizeEach
869-188900Full specifications
EachConservatIR ATR Sampling InterfaceConservatIR FTIR External Reflection Accessory45°Request A Quote***
Angle45°
Crystal TypeDiamond ATR (optional)
For Use With (Equipment)ConservatIR FTIR External Reflection Accessory
Spectral RangeMid-IR
TypeATR Sampling Head
DescriptionConservatIR ATR Sampling Interface
For Use With (Application)Art conservation, art restoration, art authentication, large sample analysis, automotive
Sampling AreaATR Mode Spot Size ∼ 0.5 mm
Unit SizeEach
Showing 3 of 3
Easily perform qualitative analysis of samples that are too large to fit within the Nicolet FTIR spectrometer sample compartment. Investigate paints, pigments, and other component materials of art objects such as sculptures, paintings, vases and more with the ConservatIR external reflection accessory for Nicolet FTIR spectrometers. Verify the authenticity of art objects before they go to auction or confirm the materials and processes needed for art restoration and conservation. 
 
The ConservatIR articulated opto-mechanical arm simplifies sample orientation to take a measurement. The arm contains an integrated camera that provides a magnified view and image capture of the sampled spot. The accessory fits into the sample compartment of a Nicolet FTIR spectrometer and measures samples oriented in front, above or slightly below the sample compartment. Applications include analysis of small or large samples via specular/diffuse reflection or ATR spectroscopy. 

ConservatIR compatible Nicolet FTIR spectrometers
  • Thermo Scientific™ Nicolet™ iS5 FTIR Spectrometer
  • Thermo Scientific™ Nicolet™ Summit FTIR Spectrometers
  • Thermo Scientific™ Nicolet™ iS20 FTIR Spectrometer 
  • Thermo Scientific™ Nicolet™ iS50 FTIR Spectrometer 
  • Thermo Scientific™ Nicolet™ iS50R Research FTIR Spectrometer
ConservatIR Accessory Features
  • Variable articulating arm angle from -5° to 90° 
  • Sampling head configurable for specular/diffuse reflection and ATR
  • Optional diamond ATR sampling interface available (45° angle of incidence)
  • Allows both contact and non-contact analysis, depending on the sample type
  • Enables analysis outside the sample compartment
  • Articulated opto-mechanical system with 100° of tilt
  • Small spot size allows analysis with high spatial resolution
  • Small sampling spot size:
    • 0.5 mm diameter for ATR
    • 1.25 mm diameter for specular/diffuse reflection
  • Spectral range: mid-IR to the far-IR, dependent on spectrometer
  • Video imaging system:
    • Magnifies the image for easy viewing
    • Directly views the sample surface
  • Integrates with your computer for real-time viewing and long-term storage of sampled images
 

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text