Gallery Enzyme Master
Gallery Enzyme Master
Actual product may vary
Thermo Scientific™

Gallery Enzyme Master

Perform robust, and reproducible enzyme assays with automated Gallery Enzyme Master. It efficiently manages many different enzymes and many different measuring conditions—all in a single instrument that offers consistent, reproducible performance.
Catalog NumberElectrochemistry Unit (ECM)Measurement MethodThroughput
98611004IncludedPhotometric: 340nm to 880nm
pH Range: 2-12 pH
Conductivity Range: 20 μS/cm – 112 mS/cm
200 Photometric Tests/hr.; up to 67 pH and conductivity measurements/hr.
98610004OptionalPhotometric: 340nm to 880nm200 Photometric Tests/hr.
2 Options
Catalog number 98611004
Price (JPY)/ Each
-
Request A Quote
Electrochemistry Unit (ECM):
Included
Measurement Method:
Photometric: 340nm to 880nm
pH Range: 2-12 pH
Conductivity Range: 20 μS/cm – 112 mS/cm
Throughput:
200 Photometric Tests/hr.; up to 67 pH and conductivity measurements/hr.
Gain confidence in your resultls with the Thermo Scientific™ Gallery™ Enzyme Master - the first automated discrete analyzers designed specifically for enzyme assay applications. Combining robust hardware and new custom-designed software, these best-in-class solutions deliver fully automated incubation settings, reagent additions and precise measurement calculations—all with a touch of a button. They offer the smartest (and fastest) way yet to streamline method development and deliver reliable results from enzyme assay analysis. The optional electrochemistry unit (ECM) allows the parallel determination of pH Optimal up to 67 samples per hour along with other photometric tests.

Confidence in your Results

• Precise temperature control
• Temperature overheating limits
• Accurate incubation time to the seconds
• Superior temperature control and lack of edge effects

Highthroughput Enzyme Assay

• Walkaway solution
• Easy to use, train, and maintain
• Many enzymes, many substrates, many methods—all on a single instrument
• Fully-automated liquid handling (sample, buffer and substrate addition, and mixing)
• Disposable cuvettes (no carryover)

Fully automated workflow

• Easy, automated method development
• Easy method transfer
• Enzyme-specific method parameters all in one central place

Traceability

• Time stamped raw data
• Audit trail
• User administration

Parallel pH Measurement

• ECM Module for parallel pH measurement
• Facilitates method development
• Up to 67 samples pH measurement per hour

Specifications
Sample Size45-90 Samples
Throughput200 Photometric Tests/hr.; up to 67 pH and conductivity measurements/hr.
Incubation Temperature25°C to 60°C
Analytical MethodDiscrete analysis
Reagent CapacityUp to 30
Electrochemistry Unit (ECM)Included
Measurement MethodPhotometric: 340nm to 880nm
pH Range: 2-12 pH
Conductivity Range: 20 μS/cm – 112 mS/cm
Unit SizeEach