Thermo Scientific™

Triton™ Series Multicollector Thermal Ionization Mass Spectrometer

카탈로그 번호: 0726203
Thermo Scientific™

Triton™ Series Multicollector Thermal Ionization Mass Spectrometer

카탈로그 번호: 0726203

Extract high-precision isotope ratio information from your samples with the Thermo Scientific™ Triton™ Series Multicollector Thermal Ionization Mass Spectrometer (TIMS).

The Thermo Scientific™ Triton™ XT TIMS integrates the established field-proven technologies from the Triton Series instruments with the latest developments in technology for isotope ratio analysis from Thermo Fisher Scientific™.

 
카탈로그 번호
0726203
제품 사이즈
Each
설명
Triton XT
포함
1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
제품 정가(KRW)
전체 사양
유형TIMS
설명Triton XT
포함1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
Unit SizeEach
카탈로그 번호
제품 사이즈
Each
설명
Triton Plus
포함
System only
제품 정가(KRW)
전체 사양
유형TIMS
설명Triton Plus
포함System only
Unit SizeEach
2 / 2 표시
카탈로그 번호사양제품 사이즈설명포함제품 정가(KRW)
0726203전체 사양
EachTriton XT1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).견적 요청하기
유형TIMS
설명Triton XT
포함1013 Ω amplifier technology with gain calibration and tau correction, central dual-channel detector (SEM/Faraday cup).
Unit SizeEach
IQLAAEGAASFAFYMAMV전체 사양
EachTriton PlusSystem only견적 요청하기
유형TIMS
설명Triton Plus
포함System only
Unit SizeEach
2 / 2 표시

The result of over two decades of development

The Thermo Scientific™ Triton XT™ TIMS is the pinnacle of over two decades of continuous development, combining outstanding technologies such as:

  • 1013Ω Amplifier Technology: extending the lower limits of the ultimate detector
  • Retarding Potential Quadrupole Lenses (RPQ): for the highest abundance sensitivity allowing high precision of extreme isotope ratios
  • Multi-ion counting (MIC) packages: dedicated for specific nuclear and geochronology applications
  • Stable and linear SEM and then CDD ion counters: for the smallest sample amounts and lowest abundance isotopes
  • High-performance Faraday cups: to guarantee uniform response and long lifetime
  • High stability thermal ionization source: characterized by a very small kinetic energy spread of the ions and optimized for maximum ion transmission for both single and double filament techniques
  • Reliable moveable collector array: brings up to 9 Faraday cups into precise alignment with ion beams of different dispersions. With a mass range to cover static Li measurements, that is extendable to cover static Ca
  • Virtual amplifier: allows cancellation of gain factor uncertainties through amplifier rotation, so that low ppm external reproducibility can be achieved using efficient static measurements