Thermo Scientific™

Smart iTR™ Attenuated Total Reflectance (ATR) Sampling Accessory

카탈로그 번호: 222-247000
Thermo Scientific™

Smart iTR™ Attenuated Total Reflectance (ATR) Sampling Accessory

카탈로그 번호: 222-247000
Eliminate sample preparation while retaining exceptional throughput with the ultra-high-performance, versatile Smart iTR Attenuated Total Reflectance (ATR) Sampling Accessory. Primarily designed for use with a single bounce diamond crystal, the Smart iTR Accessory also offers other options for full configurability. It provides exceptional sensitivity and IR throughput.
 
카탈로그 번호
222-247000
제품 사이즈
Each
Crystal Type
Diamond with ZnSe lens
제품 정가(KRW)
전체 사양
각도42°
Crystal TypeDiamond with ZnSe lens
용도 (장비)Nicolet iS10 and Nicolet iS50
스펙트럼 범위4200 to 650 cm1
유형Single-bounce ATR
설명The Smart iTR is an ultra-high-performance, single-bounce ATR providing exceptional sensitivity and IR throughput.
용도(애플리케이션)Most solids, Liquids, Acidic or alkaline materials, Fibers, Hard or oddly shaped samples, Abrasive, caustic or corrosive materials, Large or small samples, Paint chips
포함Diamond Plate and Pressure Tower
pH 범위1 to 14
압력 장치10,000 psi
샘플링 면적1.5 mm dia.
Unit SizeEach
카탈로그 번호
제품 사이즈
Each
Crystal Type
ZnSe
제품 정가(KRW)
전체 사양
각도42°
Crystal TypeZnSe
용도 (장비)Nicolet iS10 and Nicolet iS50
스펙트럼 범위20,000 to 650 cm1
유형Single-bounce ATR
설명The Smart iTR is an ultra-high-performance, single-bounce ATR providing exceptional sensitivity and IR throughput.
용도(애플리케이션)Solids, Liquids and Fibers
포함ZnSe Plate and Pressure Tower
pH 범위5 to 9
압력 장치10,000 psi
샘플링 면적1.5 mm dia.
Unit SizeEach
카탈로그 번호
제품 사이즈
Each
Crystal Type
Diamond with ZnSe lens, Ge
제품 정가(KRW)
전체 사양
각도42°
Crystal TypeDiamond with ZnSe lens, Ge
용도 (장비)Nicolet iS10 and Nicolet iS50
스펙트럼 범위Ge: 5500 to 700 cm1, Diamond: 4200 to 650 cm1
유형Single-bounce ATR
설명The Smart iTR is an ultra-high-performance, single-bounce ATR providing exceptional sensitivity and IR throughput.
용도(애플리케이션)Solids, Liquids and Fibers; Ge provides a much shallower depth of penetration, making it ideal for highly absorbing or scattering samples such as carbon-black containing rubbers
포함Diamond Plate, Ge Plate, and Pressure Tower
pH 범위1 to 14 for Ge; 1 to 12 for Diamond
압력 장치10,000 psi
샘플링 면적1.5 mm dia.
Unit SizeEach
카탈로그 번호
제품 사이즈
Each
Crystal Type
ZnSe, Ge
제품 정가(KRW)
전체 사양
각도42°
Crystal TypeZnSe, Ge
용도 (장비)Nicolet iS10 and Nicolet iS50
스펙트럼 범위Ge: 5500 to700 cm1, ZnSe: 20,000 to 650 cm1
유형Single-bounce ATR
설명The Smart iTR is an ultra-high-performance, single-bounce ATR providing exceptional sensitivity and IR throughput.
용도(애플리케이션)Solids, Liquids and Fibers; Ge provides a much shallower depth of penetration, making it ideal for highly absorbing or scattering samples such as carbon-black containing rubbers
포함ZnSe Plate, Ge Plate, and Pressure Tower
pH 범위1 to 14 for Ge; 5 to 9 for ZnSe
압력 장치10,000 psi
샘플링 면적1.5 mm dia.
Unit SizeEach
4 / 4 표시
카탈로그 번호사양제품 사이즈Crystal Type제품 정가(KRW)
222-247000전체 사양
EachDiamond with ZnSe lens견적 요청하기
각도42°
Crystal TypeDiamond with ZnSe lens
용도 (장비)Nicolet iS10 and Nicolet iS50
스펙트럼 범위4200 to 650 cm1
유형Single-bounce ATR
설명The Smart iTR is an ultra-high-performance, single-bounce ATR providing exceptional sensitivity and IR throughput.
용도(애플리케이션)Most solids, Liquids, Acidic or alkaline materials, Fibers, Hard or oddly shaped samples, Abrasive, caustic or corrosive materials, Large or small samples, Paint chips
포함Diamond Plate and Pressure Tower
pH 범위1 to 14
압력 장치10,000 psi
샘플링 면적1.5 mm dia.
Unit SizeEach
222-247100전체 사양
EachZnSe견적 요청하기
각도42°
Crystal TypeZnSe
용도 (장비)Nicolet iS10 and Nicolet iS50
스펙트럼 범위20,000 to 650 cm1
유형Single-bounce ATR
설명The Smart iTR is an ultra-high-performance, single-bounce ATR providing exceptional sensitivity and IR throughput.
용도(애플리케이션)Solids, Liquids and Fibers
포함ZnSe Plate and Pressure Tower
pH 범위5 to 9
압력 장치10,000 psi
샘플링 면적1.5 mm dia.
Unit SizeEach
222-247200전체 사양
EachDiamond with ZnSe lens, Ge견적 요청하기
각도42°
Crystal TypeDiamond with ZnSe lens, Ge
용도 (장비)Nicolet iS10 and Nicolet iS50
스펙트럼 범위Ge: 5500 to 700 cm1, Diamond: 4200 to 650 cm1
유형Single-bounce ATR
설명The Smart iTR is an ultra-high-performance, single-bounce ATR providing exceptional sensitivity and IR throughput.
용도(애플리케이션)Solids, Liquids and Fibers; Ge provides a much shallower depth of penetration, making it ideal for highly absorbing or scattering samples such as carbon-black containing rubbers
포함Diamond Plate, Ge Plate, and Pressure Tower
pH 범위1 to 14 for Ge; 1 to 12 for Diamond
압력 장치10,000 psi
샘플링 면적1.5 mm dia.
Unit SizeEach
222-247300전체 사양
EachZnSe, Ge견적 요청하기
각도42°
Crystal TypeZnSe, Ge
용도 (장비)Nicolet iS10 and Nicolet iS50
스펙트럼 범위Ge: 5500 to700 cm1, ZnSe: 20,000 to 650 cm1
유형Single-bounce ATR
설명The Smart iTR is an ultra-high-performance, single-bounce ATR providing exceptional sensitivity and IR throughput.
용도(애플리케이션)Solids, Liquids and Fibers; Ge provides a much shallower depth of penetration, making it ideal for highly absorbing or scattering samples such as carbon-black containing rubbers
포함ZnSe Plate, Ge Plate, and Pressure Tower
pH 범위1 to 14 for Ge; 5 to 9 for ZnSe
압력 장치10,000 psi
샘플링 면적1.5 mm dia.
Unit SizeEach
4 / 4 표시
  • Ideal for the analysis of solids, liquids, pastes and gels
  • Available with different crystals for diverse sampling needs
  • Single reflection crystal for general purpose material identification
  • Optional three reflection crystal for increased sensitivity
  • Optional specular plate gives extra flexibility when analyzing coatings on reflective materials
  • Crystal plates are pinned in place with quick-release mounting for easy removal for cleaning or swapping and reproducible insertion with no alignment required
  • ATR crystal plates are backed with a ZnSe focusing optic for optimal performance
  • Large top plate accommodates most samples
  • PTFE coated plate lifts clear easily for simple clean-up
  • Precision machining and an nonreactive gasket provide a tight interface between the top plate and the crystal housing, so spills are not a problem
  • High pressure clamp calibrated to deliver up to 10,000 psi of pressure and comes with interchangeable tips for hard, soft and pellet shaped samples
  • Active Sample Area: 1.5mm for the single bounce ATR and 6mm for the 3 bounce ATR
  • Specular Plate: Spectral range dependent on spectrometer; incident angle is 45°
The Smart iTR accessory can be ordered with three common ATR crystals fixed in stainless steel as standard: diamond, ZnSe and germanium. Each crystal performs strongly under specific circumstances.

Diamond ATR Crystal

Features

  • Inert and robust — excellent for the analysis of hard, abrasive, reactive, caustic or corrosive materials
  • A multi-purpose ATR with a depth of penetration of over 2μm at 1000cm-1 and is used with a wide variety of samples
  • Five-year warranty provided
  • Configuration can be validated
  • Disadvantage — intrinsic absorbtion from approximately 2300 to 1800cm-1

Specifications

  • Low wavenumber cutoff: 650cm-1 (due to ZnSe lens)
  • Depth of penetration: 2.03μm at 1000cm-1
  • Refractive index: 2.4
  • Useful pH range: 1 to 14 (ZnSe 5 to 9)
  • Incident angle: 42°

ZnSe ATR Crystal Features

  • Most common ATR crystal — provides an excellent performing, lower cost option for general analyses
  • Offers similarly outstanding throughput and a depth of penetration similar to diamond
  • Can be used for a wide variety of samples, but is soft and not as chemically inert as the other crystals
  • Over time it can be etched by acids and scratched by hard samples, which will eventually reduce sensitivity
  • Configuration can be validated

Specifications

  • Low wavenumber cutoff: 650cm-1
  • Depth of penetration: 2.03μm at 1000cm-1
  • Refractive index: 2.4
  • Useful pH range: 5 to 9
  • Incident angle: 42°

Germanium ATR Crystal

Features

  • Hard and inert (although not as robust as diamond) with a high refractive index
  • Provides a much shallower depth of penetration, making it ideal for highly absorbing or scattering samples such as carbon-black containing rubbers
  • Provides huge performance through the mid-IR range, with upwards of 50% transmittance
  • Offers a limited range, but good chemical resistivity to both acids and bases

Specifications

  • Low wavenumber cutoff: 700cm-1
  • Depth of penetration: 0.67μm at 1000cm-1
  • Refractive index: 4.0
  • Useful pH range: 1 to 14
  • Incident angle: 42°

Silicon ATR Crystal

Features

  • Hard, with a high refractive index
  • Useful for strong absorbers or abrasive samples
  • Suitable for temperature studies because it withstands thermal shock

Specifications

  • Low wave number cutoff: 700cm-1
  • Depth of penetration: 0.84μm at 1000cm-1
  • Refractive index: 3.4
  • Useful pH range: 1 to 12 Incident angle: 42°

Compatible with:

The Smart iTR Accessory is compatible with the Thermo Scientific™ Nicolet™ iS™ 10 FT-IR Spectrometer, the Thermo Scientific™ Nicolet™ iZ™ 10 Auxiliary Module, and the Nicolet 6700 and Nicolet 8700 FT-IR Spectrometers.

Recommended for:

  • Most solids
  • Liquids ranging from pH 1 to 14
  • Acidic or alkaline materials
  • Fibers
  • Hard or oddly shaped samples
  • Abrasive, caustic or corrosive materials
  • Large or small samples
  • Paint chips

그림

문서 및 다운로드

Certificates | 증명서

    자주 묻는 질문(FAQ)

    인용 및 참조 문헌

    Search citations by name, author, journal title or abstract text