Thermo Scientific™

TRACE™ 1310 GC Greenhouse Gas Analyzers

카탈로그 번호: GHA000010021
Thermo Scientific™

TRACE™ 1310 GC Greenhouse Gas Analyzers

카탈로그 번호: GHA000010021
Measure greenhouses gases and report on sample results with automated Thermo Scientific™ TRACE™ 1310 GC Greenhouse Gas Analyzers. Preconfigured and method tested, these systems make it easy to analyze your samples. Run one sample at a time or add a headspace autosampler to run multiple samples automatically. The Thermo Scientific™ Chromeleon™ Chromatography Data System (CDS) provides a powerful software tool to acquire and analyze your GC data. Each system is delivered with methods pre-installed and a complete documentation package, including a start-up guide, troubleshooting tips, a plumbing diagram, and spare parts/consumables list for easy ordering.
 
카탈로그 번호
GHA000010021
제품 사이즈
Each
설명
3-channel gas chromatograph with configured valve oven
포함
TRACE 1310 GC with one FID detector, one ECD detector, one TCD detecor, Auxiliary valve oven with (2) 10-port valves, 4 columns, and complete documentation package. System is fully assembled and factory tested.
제품 정가(KRW)
전체 사양
유형Greenhouse Gas Analyzer
검출 모드Flame Ionization, Electron Capture, Thermal Conductivity
컬럼 용량6
설명3-channel gas chromatograph with configured valve oven
포함TRACE 1310 GC with one FID detector, one ECD detector, one TCD detecor, Auxiliary valve oven with (2) 10-port valves, 4 columns, and complete documentation package. System is fully assembled and factory tested.
기능Automated analysis of a gas sample for green house gases, CH4, CO2, and N2O.
검출기 유형FID, ECD, TCD
Unit SizeEach
카탈로그 번호
제품 사이즈
Each
설명
Dual-channel gas chromatograph with configured valve oven
포함
TRACE 1310 GC with one FID detector, one ECD detector, Auxiliary valve oven with (2) 10-port valves, 4 columns, a methanizer and complete documentation package. System is fully assembled and factory tested.
제품 정가(KRW)
전체 사양
유형Greenhouse Gas Analyzer
검출 모드Flame Ionization and Electron Capture
컬럼 용량6
설명Dual-channel gas chromatograph with configured valve oven
포함TRACE 1310 GC with one FID detector, one ECD detector, Auxiliary valve oven with (2) 10-port valves, 4 columns, a methanizer and complete documentation package. System is fully assembled and factory tested.
기능Automated analysis of a gas sample for greenhouse gases, CH4, CO2, and N2O.
검출기 유형FID and ECD
Unit SizeEach
2 / 2 표시
카탈로그 번호사양제품 사이즈설명포함제품 정가(KRW)
GHA000010021전체 사양
Each3-channel gas chromatograph with configured valve ovenTRACE 1310 GC with one FID detector, one ECD detector, one TCD detecor, Auxiliary valve oven with (2) 10-port valves, 4 columns, and complete documentation package. System is fully assembled and factory tested.연락처 ›
유형Greenhouse Gas Analyzer
검출 모드Flame Ionization, Electron Capture, Thermal Conductivity
컬럼 용량6
설명3-channel gas chromatograph with configured valve oven
포함TRACE 1310 GC with one FID detector, one ECD detector, one TCD detecor, Auxiliary valve oven with (2) 10-port valves, 4 columns, and complete documentation package. System is fully assembled and factory tested.
기능Automated analysis of a gas sample for green house gases, CH4, CO2, and N2O.
검출기 유형FID, ECD, TCD
Unit SizeEach
GHA000010011전체 사양
EachDual-channel gas chromatograph with configured valve ovenTRACE 1310 GC with one FID detector, one ECD detector, Auxiliary valve oven with (2) 10-port valves, 4 columns, a methanizer and complete documentation package. System is fully assembled and factory tested.연락처 ›
유형Greenhouse Gas Analyzer
검출 모드Flame Ionization and Electron Capture
컬럼 용량6
설명Dual-channel gas chromatograph with configured valve oven
포함TRACE 1310 GC with one FID detector, one ECD detector, Auxiliary valve oven with (2) 10-port valves, 4 columns, a methanizer and complete documentation package. System is fully assembled and factory tested.
기능Automated analysis of a gas sample for greenhouse gases, CH4, CO2, and N2O.
검출기 유형FID and ECD
Unit SizeEach
2 / 2 표시
Two systems to choose from:
  • Two-channel system with FID-ECD analysis
    • FID channel & methanizer detects methane (CH4) and CO2 after converting to CH4 in the methanizer
    • ECD detects nitrous oxide (N2O)
  • Three Channel system with FID-ECD-TCD analysis
    • FID Channel detects methane (CH4)
    • ECD Channel detects nitrous oxide (N2O)
    • TCD Channel detects carbon dioxide (CO2)
Built to maximize productivity and uptime
  • Two oven design - temperature programmable GC oven and independent isothermal valve oven can hold up to 6 packed columns for optimal column management
  • System features Instant Connect detector modules increasing uptime with detector exchange in minutes
  • Spacious independent valve oven with easy access to valves, rotors, actuators
  • Heated sample bulkheads ensure complete sample transfer
  • Optimized system footprint to reduce bench space requirement

그림

문서 및 다운로드

Certificates | 증명서

    자주 묻는 질문(FAQ)

    인용 및 참조 문헌

    Search citations by name, author, journal title or abstract text