Acclaim™ 120 C18 Columns
Actual product may vary
Thermo Scientific™
Acclaim™ 120 C18 Columns
Use these high-efficiency reversed phase C18 columns for maximum resolution in a wide variety of applications.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberParticle SizeDiameter (Metric)Length (Metric)
0591495 μm4.6 mm250 mm
0591425 μm2.1 mm50 mm
0591435 μm2.1 mm100 mm
0591445 μm2.1 mm150 mm
0591455 μm2.1 mm250 mm
0591465 μm4.6 mm50 mm
0591475 μm4.6 mm100 mm
0591485 μm4.6 mm150 mm
0761873 μm2.1 mm250 mm
0761863 μm3 mm100 mm
0748122.2 μm2.1 mm250 mm
0716052.2 μm3 mm50 mm
0716042.2 μm3 mm100 mm
0714002.2 μm2.1 mm30 mm
0713992.2 μm2.1 mm150 mm
0700773 μm3 mm250 mm
0689822.2 μm2.1 mm100 mm
0689812.2 μm2.1 mm50 mm
0662733 μm3 mm75 mm
0662723 μm3 mm33 mm
0636913 μm3 mm150 mm
0591333 μm4.6 mm150 mm
0591323 μm4.6 mm100 mm
0591313 μm4.6 mm50 mm
0591303 μm2.1 mm150 mm
0591293 μm2.1 mm100 mm
0719815 μm3 mm10 mm
0696955 μm4.6 mm10 mm
0696895 μm2.1 mm10 mm
0591283 μm2.1 mm50 mm
0756972.2 μm3 mm75 mm
31 Options
Catalog number 059149
Price (TWD)/ Each
-
Request A Quote
Particle Size:
5 μm
Diameter (Metric):
4.6 mm
Length (Metric):
250 mm

Improve the separation efficiency in your reversed-phase applications with Thermo Scientific™ Acclaim™ 120 C18 columns. These columns feature an ultrapure silica substrate with extremely low metal content to minimize tailing effects and deliver symmetrical peak shapes. The unique bonding chemistry yields excellent surface coverage to provide highly predictable separations that are unaffected by secondary interactions. Use these high-efficiency columns for maximum resolution in a wide variety of applications.

High Performance Reversed-Phase Columns for Reproducible Results
  • Very high surface coverage and very low metal content together result in columns with excellent efficiencies
  • Reproducible column-to-column performance
  • Extremely low bleed, fully compatible with MS
  • Stable between pH 2 and 8
  • Available in 2.2, 3, and 5μm particle sizes and 4.6, 3.0, and 2.1mm diameters, with an average pore diameter of 120Å
  • Also available in 2.2μm RSLC format for reliable, fast separations
About the Acclaim Family of HPLC Columns

Achieve the high standards set by modern HPLC and LC/MS methods with the Acclaim family of reversed-phase columns. These silica-based columns with advanced column bonding and endcapping technologies provide complementary selectivity, high column efficiencies, and ultra-high resolution for a wide variety of applications.

  • Broad spectrum of stationary phases, including conventional C8 and C18 phases, polar embedded phases, and specialty phases including wide-pore, are available to meet your specific application needs
  • Performance tested to ensure high quality and reliability for pharmaceutical, biopharmaceutical, environmental, food, and other industrial chromatographic separations
Specifications
Column FormatAnalytical Column
Diameter (Metric)4.6 mm
Length (Metric)250 mm
Max. Pressure4500 psi (310 bar)
Particle Size5 μm
pH2 to 8
Pore Size120 Å
Surface Area300 m²/g
Temperature60°C
USP TypeL1
Stationary PhaseC18
Product LineAcclaim
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Carbon Load18%
Column TypeReversed Phase
EndcappedYes
PhaseReversed Phase
Unit SizeEach