Sentinel PRO Environmental Mass Spectrometer
Sentinel PRO Environmental Mass Spectrometer
Thermo Scientific™

Sentinel PRO Environmental Mass Spectrometer

Ensure plant safety by enabling leak detection and correction before any toxic hazard is created with the Thermo Scientific™ Sentinel PRO Environmental Mass Spectrometer.
Have Questions?
Catalog NumberProduct Type
SENTINELPROSentinel PRO Environmental Ambient Air Trace VOC Gas Analysis Mass Spectrometer
Catalog number SENTINELPRO
Price (TWD)
-
Request A Quote
Product Type:
Sentinel PRO Environmental Ambient Air Trace VOC Gas Analysis Mass Spectrometer
Ask our AI about this Product
Ensure plant safety by enabling leak detection and correction before any toxic hazard is created with the Thermo Scientific™ Sentinel PRO Environmental Mass Spectrometer. This next-generation environmental mass spectrometer is engineered to help plants monitor fugitive emissions of toxic organic vapors, protecting workers and surrounding environment from hazardous exposure.

The fast, precise and reliable Sentinel PRO environmental mass spectrometer can monitor 100 or more sample points within 15 minutes. It features species-specific detection of a number of volatile organic compounds (VOCs) in the 1ppm - 100ppm range. A rugged fault-tolerant design ensures availability exceeds 99.7% and simplified maintenance procedures make it easy to own. A single Sentinel PRO analyzer can replace an entire rack of less sensitive, discrete analyzers to improve detection capabilities and significantly reduce maintenance and ongoing operating costs.

Increased Sensitivity, Precision, Accuracy, and Mass Range:

  • Completely redesigned electronics, incorporating higher specification components
  • Capable of monitoring 100 or more sample points within 15 minutes
  • Species-specific detection of VOCs in the 1ppm - 100ppm range
  • Reliable, fault-tolerant design for availability of greater than 99.7%
  • Significantly enhanced analyzer control
  • Enhanced connectivity to DCS systems and off-line data manipulation packages

Features:

  • Offers high number of sample points that can be located close to potential leak points (i.e. valve stems, etc.)
  • Unique rapid multi-stream sampler (RMS) with 32 or 64 ports
  • Stable with 30- to 90-day automated calibration interval
  • Complete service access from the front of the system, reducing the effective footprint
  • Small footprint with no large shelter required
  • Minimal maintenance requirements
  • Thermo Scientific™ GasWorks software
Specifications
Analysis Time0.3 to 1.0 sec. per gas component
Analyzer TypeScanning Magnetic Sector Mass Spectrometer with Enclosed Electron Impact Dual Filament Ion Source
Area Classification OptionsGeneral Purpose; Z-purged Class 1 Div 2 (optional); ATEX Zone 1, IIC T3 (optional)
Depth (English)2.7 ft.
Depth (Metric)0.8 m
Dynamic Range10 ppb to 100 ppm or 100 ppb to 1000 ppm
Height (English)GP: 5 ft., Ex: 6 ft.
Height (Metric)GP: 1.5 m, Ex: 1.8 m
No. of Calibration Gas InletsUp to 6 (standard); optional to 24
No. of Sample Stream InletsUp to 31 or 63 (standard); optional to 126
Power115/230 V, Consumption GP: 2.0 kVA; Ex: 2.5 kVA
Precision≤±0.5 ppm over 24 hours, ≤±1 ppm at 10 ppm concentration over 1 month
Weight (English)530 lb.
Weight (Metric)240 kg
Width (English)3.3 ft.
Width (Metric)1 m
Ambient Temperature12°C to 40°C
Communication ProtocolsModbus serial RS232/422/485, Siemens 3964R, VGCP and PVGCP; optional via protocol converters: Modbus Ethernet TCP/IP and Profibus DP
Mass RangeAdjustable, 1 to 150 amu at 1000 eV ion acceleration voltage, 1 to 300 amu at 500 eV ion acceleration voltage
Product TypeSentinel PRO Environmental Ambient Air Trace VOC Gas Analysis Mass Spectrometer
Unit SizeEach
access the user manuals for mass spectrometry instruments

To access the user manuals of your online mass spectrometer, please contact us directly:
email: Techsupport.epm.europe@thermofisher.com
phone:  +44 1606 548 753

Service Offerings

  • Field Service Support
  • Technical Support
  • Repairs & Calibrations
  • Technical Training
  • Spare Parts Catalogs
  • Promotions & much more…

Purchase Spare Parts
Order Spare parts 24/7 via credit card or PO
(United States customers only)

Factory Service Depot
Request an RMA number for a repair or calibration at one of our facilities

Signup NOW for our quarterly service newsletter for the latest news & updates!

Have questions about this product? Ask our AI assisted search.
This is an AI-powered search and may not always get things right. You can help us make it better with a thumbs up or down on individual answers or by selecting the “Give feedback" button. Your search history and customer login information may be retained by Thermo Fisher and processed in accordance with our Privacy Notice.

Frequently asked questions (FAQs)

Information is provided to aid in the running of Gasworks Software in a 21 CFR Part 11 compliant environment. It should be noted that system qualification, validation, and implementation of standard operating procedures are essential elements of Part 11 compliance that cannot be achieved through software functionality alone. While many of the requirements in the regulations are addressed by Thermo Fisher Scientific software features, all aspects of the system must be validated by the customer or their designee.

The Modbus Register Mapping Wizard requires the operator to respond to a series of questions regarding the data to be communicated and the address area to be reserved. This becomes an editable table of values.

A number of different user groups are defined by the system administrator. Each group can be provided with a configurable set of access permissions. The administrator is given the option of limiting the number of password retries, assigning an expiration date for passwords, enabling an audit trail, and setting automatic log out.

The System Wizard fully documents the analyzer hardware. This electronic manual allows the operator to drill down to a component of interest. A brief explanation of selected item is provided with tutorial views and a parts manual.

GasWorks Software has its own data review program that can be installed on an office PC and reviewed offline.

Share catalog number, name or link

1x1 image pixel for data collection