Acclaim™ Explosives E2 HPLC Columns
Actual product may vary
Thermo Scientific™
Acclaim™ Explosives E2 HPLC Columns
Use for baseline resolution of all 14 explosives listed in EPA Method 531.2.
Have Questions?
變更視圖buttonViewtableView
產品號碼Particle SizeDiameter (Metric)Length (Metric)
0719895 μm3 mm10 mm
0700813 μm3 mm250 mm
0700823 μm3 mm150 mm
0643095 μm4.6 mm250 mm
0697035 μm4.6 mm10 mm
0762262.2 μm2.1 mm150 mm
6 選項
產品號碼 071989
價格 (TWD)/ Pack of 2
-
申請報價
Particle Size:
5 μm
Diameter (Metric):
3 mm
Length (Metric):
10 mm
Achieve baseline resolution of all 14 explosives listed in EPA SW-846 Method 8330 with Thermo Scientific™ Acclaim™ Explosives E2 LC Columns, Nitroaromatics and Nitramines by HPLC. Their unique column chemistries deliver superior resolution with complementary selectivities. Use the E1 column (available separately) as a direct replacement for ODS columns for primary analysis. Then, use the E2 column as either a primary or a confirmatory column. Easily change the separation conditions for the E2 column to accommodate a wider application range, including the analysis of explosives beyond U.S. EPA Method 8330.
Superior Performance for Explosives Analysis
  • Reproducible performance
  • Simple isocratic elution conditions
  • Unique selectivities for separating other nitroaromatic molecules
  • Rugged columns with good lot-to-lot reproducibility
About the Family of Acclaim Specialty HPLC Columns
  • Developed, manufactured and tested to meet the needs of specific applications
  • Columns provide superior resolution with ease of use
  • Use-tested to guarantee consistent separations
  • Ideal selectivity for separating specific target analytes
  • Excellent peak shapes
  • Performance tested to ensure high quality and reliability
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.
規格
Column FormatGuard Cartridge, 2 Pk.
Diameter (Metric)3 mm
For Use WithLC/MS
Length (Metric)10 mm
Max. Pressure8700 psi (600 bar)
Particle Size5 μm
pH2.5 to 7.5
Pore Size120 Å
Surface Area300 m²/g
Temperature50°C
USP TypeN/A
Stationary PhaseProprietary
Product LineAcclaim
Packing MaterialSilica
Column TypeSpecialty/Application Specific
EndcappedYes
PhaseReversed Phase
TypeGuard Cartridge
Unit SizePack of 2