Invitrogen™

NovaFluor™ CD4 Label Characterization Kits

產品號碼: K03T01L001
Invitrogen™

NovaFluor™ CD4 Label Characterization Kits

產品號碼: K03T01L001
NovaFluor CD4 Label Characterization kits are formulated to enable the testing of all available NovaFluors as direct conjugates of CD4. These kits can be used to evaluate performance of NovaFluors on flow cytometers.
 
產品號碼
K03T01L001
Unit Size
10 tests
Description
NovaFluor™ Mouse CD4 Label Characterization Kit 1
價格 (TWD)
價格 24,500.00
線上優惠 19,600.00
(01-Oct-2024 結束)
您的價格
供應狀況
-
完整規格
數量
DescriptionNovaFluor™ Mouse CD4 Label Characterization Kit 1
For Use With (Application)Flow Cytometry
Label or DyeLabel
No. of Tests10 tests
Quantity1 kit
Regulatory StatusRUO
Shipping ConditionRoom Temperature
Unit Size10 tests
產品號碼
Unit Size
10 tests
Description
NovaFluor™ Human CD4 Label Characterization Kit 1
價格 (TWD)
價格 24,500.00
線上優惠 19,600.00
(01-Oct-2024 結束)
您的價格
供應狀況
-
完整規格
數量
DescriptionNovaFluor™ Human CD4 Label Characterization Kit 1
For Use With (Application)Flow Cytometry
Label or DyeLabel
No. of Tests10 tests
Quantity1 kit
Regulatory StatusRUO
Shipping ConditionRoom Temperature
Unit Size10 tests
產品號碼
Unit Size
10 tests
Description
NovaFluor™ Human CD4 Label Characterization Kit 2
價格 (TWD)
價格 36,500.00
線上優惠 29,200.00
(01-Oct-2024 結束)
您的價格
供應狀況
-
完整規格
數量
DescriptionNovaFluor™ Human CD4 Label Characterization Kit 2
For Use With (Application)Flow Cytometry
Label or DyeLabel
No. of Tests10 tests
Quantity1 kit
Regulatory StatusRUO
Shipping ConditionRoom Temperature
Unit Size10 tests
產品號碼
Unit Size
10 tests
Description
NovaFluor™ Mouse CD4 Label Characterization Kit 2
價格 (TWD)
價格 36,500.00
線上優惠 29,200.00
(01-Oct-2024 結束)
您的價格
供應狀況
-
完整規格
數量
DescriptionNovaFluor™ Mouse CD4 Label Characterization Kit 2
For Use With (Application)Flow Cytometry
Unit Size10 tests
顯示 4 項,共 4 項
產品號碼規格Unit SizeDescription價格 (TWD)供應狀況數量
K03T01L001完整規格
10 testsNovaFluor™ Mouse CD4 Label Characterization Kit 1
價格 24,500.00
線上優惠 19,600.00
(01-Oct-2024 結束)
您的價格
-
DescriptionNovaFluor™ Mouse CD4 Label Characterization Kit 1
For Use With (Application)Flow Cytometry
Label or DyeLabel
No. of Tests10 tests
Quantity1 kit
Regulatory StatusRUO
Shipping ConditionRoom Temperature
Unit Size10 tests
K02T01L001完整規格
10 testsNovaFluor™ Human CD4 Label Characterization Kit 1
價格 24,500.00
線上優惠 19,600.00
(01-Oct-2024 結束)
您的價格
-
DescriptionNovaFluor™ Human CD4 Label Characterization Kit 1
For Use With (Application)Flow Cytometry
Label or DyeLabel
No. of Tests10 tests
Quantity1 kit
Regulatory StatusRUO
Shipping ConditionRoom Temperature
Unit Size10 tests
K04T01L022完整規格
10 testsNovaFluor™ Human CD4 Label Characterization Kit 2
價格 36,500.00
線上優惠 29,200.00
(01-Oct-2024 結束)
您的價格
-
DescriptionNovaFluor™ Human CD4 Label Characterization Kit 2
For Use With (Application)Flow Cytometry
Label or DyeLabel
No. of Tests10 tests
Quantity1 kit
Regulatory StatusRUO
Shipping ConditionRoom Temperature
Unit Size10 tests
K05T01L022完整規格
10 testsNovaFluor™ Mouse CD4 Label Characterization Kit 2
價格 36,500.00
線上優惠 29,200.00
(01-Oct-2024 結束)
您的價格
-
DescriptionNovaFluor™ Mouse CD4 Label Characterization Kit 2
For Use With (Application)Flow Cytometry
Unit Size10 tests
顯示 4 項,共 4 項

NovaFluor CD4 Label Characterization kits are formulated to enable the testing of available NovaFluor dyes as direct conjugates of CD4. These kits can be used to characterize and evaluate the performance of NovaFluor dyes.

NovaFluor CD4 Label Characterization Kits include:
• NovaFluor antibody conjugates of anti-human CD4 (clone SK3) or anti-mouse CD4 (clone GK1.5), 10 tests of each antibody conjugate per vial.
• CellBlox Blocking Buffer
• Kit 1 dyes: NovaFluor Blue 530, NovaFluor Blue 610-30S, NovaFluor Blue 660-40S, NovaFluor Yellow 570, NovaFluor Yellow 610, NovaFluor Yellow 660
• Kit 2 dyes: NovaFluor Blue 510, NovaFluor Blue 555, NovaFluor Blue 610-70S, NovaFluor Blue 660-120S, NovaFluor Yellow 690, NovaFluor Yellow 700, NovaFluor Red 660, NovaFluor Red 685, NovaFluor Red 700

NovaFluor Dyes include the following features:
• Unique spectral signatures designed with narrow emission and minimal cross-laser excitation
• Decreased spillover/spread for higher biological resolution
• Easily added to new and existing panels to fill in spectral gaps
• Ideal for both conventional and spectral flow cytometers

NovaFluor dyes are not compatible with DNA -binding dyes. Do not use viability dyes such as propidium iodide, 7-actinomycin D (7-AAD), or DAPI. Invitrogen LIVE/DEAD Fixable Dead Cell stains are recommended for use with NovaFluor dyes.

Each NovaFluor conjugate or kit is shipped with CellBlox Blocking Buffer. Use this buffer whenever you are staining with NovaFluor conjugates, including single-color controls using cells. Use 5 μL of CellBlox Blocking Buffer per stained cell sample containing 103 to 108 cells with 100 μL as a final staining volume.

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text