For researchers pursuing the next scientific breakthrough, the Thermo Scientific Vanquish Neo UHPLC system delivers maximum performance 24/7 for reproducible nano-, capillary-, and micro-flow LC-MS. Combining a high degree of innovation with the best-in-class Vanquish platform enhances productivity for novice and expert LC-MS users alike.


Highlights

All-in-one nano-, capillary-, and micro-flow LC

Thermo Scientific ProFlow™ XR active flow control pump technology delivers excellent retention time precision from nano up to 100 μL/min at pressures up to 1500 bar. Vial bottom detection enables injections from volume-limited samples.

Accelerated productivity

Fast sample loading, column equilibration and ultra-low system gradient delay volume reduce method overhead time, improving sample throughput while enhancing MS utilization. The tandem direct injection workflow accelerates productivity further by eliminating sample loading, gradient delay, column washing, and column equilibration from method cycle time.

Maximized performance

Unique low-flow split-loop autosampler design limits sample dispersion, reduces system carryover, and maximizes sample usage. The metering device improves quantitation through high injection volume linearity, precision, and accuracy.

Long-term, trouble-free analysis

Next-generation Thermo Scientific SmartInject technology improves column lifetime and retention time precision. Maintenance-free 1500 bar compatible ceramic valves and near-zero dead volume Thermo Scientific Viper and nanoViper fittings minimize leaks with robust long-term operation.

Intelligent operation

The Thermo Scientific Vanquish User Interface provides walk-up and remote system monitoring and control with automated procedures and guided instrument maintenance and troubleshooting scripts, improving productivity for all users. The intelligent method editor wizard ensures compatibility of method parameters with installed consumables.

Seamless LC-MS integration

The Vanquish Neo UHPLC system excels at high-sensitivity LC-MS applications and seamlessly integrates with the Thermo Scientific mass spectrometry portfolio through a comprehensive suite of ESI sources. Harness speed, robustness and sensitivity with triple quadrupole MS systems or resolution, mass accuracy, and versatility with Thermo Scientific Orbitrap MS systems.


Videos

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • captions off, selected

      Video Player is loading.
      Current Time 0:00
      Duration 0:00
      Loaded: 0%
      Stream Type LIVE
      Remaining Time 0:00
       
      1x
        • Chapters
        • descriptions off, selected
        • captions off, selected

          Video Player is loading.
          Current Time 0:00
          Duration 0:00
          Loaded: 0%
          Stream Type LIVE
          Remaining Time 0:00
           
          1x
            • Chapters
            • descriptions off, selected
            • captions off, selected

              Video Player is loading.
              Current Time 0:00
              Duration 0:00
              Loaded: 0%
              Stream Type LIVE
              Remaining Time 0:00
               
              1x
                • Chapters
                • descriptions off, selected
                • captions off, selected

                  Video Player is loading.
                  Current Time 0:00
                  Duration 0:00
                  Loaded: 0%
                  Stream Type LIVE
                  Remaining Time 0:00
                   
                  1x
                    • Chapters
                    • descriptions off, selected
                    • captions off, selected

                      Video Player is loading.
                      Current Time 0:00
                      Duration 0:00
                      Loaded: 0%
                      Stream Type LIVE
                      Remaining Time 0:00
                       
                      1x
                        • Chapters
                        • descriptions off, selected
                        • captions off, selected


                          Explore a new dimension in proteomics quantitation

                          System specifications

                          The table below provides an overview of the Vanquish Neo UHPLC system specifications for a standard set up. Not all specifications are listed. For additional information, download the Vanquish Neo UHPLC System specifications sheet.

                          Category

                          Vanquish Neo UHPLC System

                          System pressure, maximum

                          1500 bar

                          Flow range

                          1 nL/min – 100 μL/min, in 1 nL increments 

                          (100 nL/min – 100 μL/min, recommended)

                          Pump options (default gradient delay volume)

                          Binary (< 25 nL)

                          Biocompatible

                          Yes

                          pH range

                          2 – 10 

                          System design

                          Integrated, with slide-in modules

                          Touchscreen user interface display compatible

                          Yes

                          Active flow control for maximum retention time precision

                          Yes, Thermo Scientific ProFlow XR pump technology

                          SmartInject technology for maximum injection precision and improved column lifetime

                          Yes

                          Injection volume range

                          Standard: 0.01–25 μL
                          Optional: 0.01–100 μL
                          High volume trapping by multiple draw-and-trap cycles up to 500 μL 

                          Sample cooling

                          Yes, 4 – 40°C 

                          Sample capacity (standard)

                          Based on standard 12 mm OD vials (≤ 1.5 mL)

                          4 racks of 54 vials (≤ 1.5 mL) each, other rack formats available 
                          + capacity of 12 × 22.5 mm OD vials (≤ 10 mL) in the carousel

                          Sampler extension available (optional)

                          No

                          Column compartment thermostatting

                          Yes (optional) 
                          Minimum 5 K above room temperature to 80 ⁰C
                          Forced air

                          Column compartment pre-heater

                          Passive (optional)

                          Column compartment post-column cooler

                          No

                          Workflows Direct injection
                          Tandem direct injection
                          Trap-and-elute
                          Heated trap-and-elute

                          Detector choices

                          Mass spectrometry
                          Variable wavelength detector F

                          Optional add-on components Column Compartment N
                          Binary Pump N

                          Contact us to get a quote or discuss an HPLC/UHPLC solution


                          For Research Use Only. Not for use in diagnostic procedures.

                           

                           

                           

                          1x1 image pixel for data collection