NovaFluor Dyes

See your cells in a whole new light

NovaFluor dyes are designed with narrow excitation for minimal cross-laser excitation for spectral and traditional flow cytometry to deliver high resolution. Lower spectral spillover or overlap lessens the need for compensation, decreases spreading error, and increases opportunities to add new markers. This aids in construction of flow cytometry panels with increased resolution while expanding the overall size of panels. NovaFluor conjugated antibodies represent foundational technology in the rapidly expanding world of flow cytometry. Learn more about our total spectral flow cytometry offerings.

Explore more about the advantages of using NovaFluor dyes:

And to enhance NovaFluor data resolution by blocking dye-to-cell interactions, use Invitrogen CellBlox Plus Blocking Buffer.


NovaFluor dye selection guide

Use the table below to select a NovaFluor dye and see available conjugated antibodies. Check stain index for brightness here

Ultra Violet
(Ex/Em max)

Violet
(Ex/Em max)

Blue
(Ex/Em max)

Yellow
(Ex/Em max)

Red
(Ex/Em max)

NovaFluor UV 765 dye*
NovaFluor UV 765 antibodies
(358/763 nm)
NovaFluor Violet 690 dye*
NovaFluor Violet 690 antibodies*
(408/691 nm)
NovaFluor Blue 510 dye
Nova Fluor Blue 510 antibodies
(496/511 nm)
NovaFluor Yellow 570 dye
NovaFluor Yellow 570 antibodies
(552/568 nm)
NovaFluor Red 660 dye
NovaFluor Red 660 antibodies
(637/659 nm)
  NovaFluor Violet 745 dye*
NovaFluor Violet 745 antibodies*
(391/743 nm)
NovaFluor Blue 530 dye
NovaFluor Blue 530 antibodies
(509/530 nm)
NovaFluor Yellow 590 dye
NovaFluor Yellow 590 antibodies
(552/590 nm)
NovaFluor Red 685 dye
NovaFluor Red 685 antibodies
(637/685 nm)
  NovaFluor Violet 800 dye*
NovaFluor Violet 800 antibodies*
(408/800 nm)
NovaFluor Blue 555 dye
NovaFluor Blue 555 antibodies
(494/555 nm)
NovaFluor Yellow 610 dye
NovaFluor Yellow 610 antibodies
(552/612 nm)
NovaFluor Red 700 dye
NovaFluor Red 700 antibodies
(639/700 nm)
    NovaFluor Blue 585 dye
NovaFluor Blue 585 antibodies
(494/585nm)
NovaFluor Yellow 660 dye
NovaFluor Yellow 660 antibodies
(552/663 nm)
NovaFluor Red 710 dye
NovaFluor Red 710 antibodies
(639/710 nm)
    NovaFluor Blue 610-30S dye
NovaFluor Blue 610-30S antibodies
(509/614 nm)
NovaFluor Yellow 690 dye
NovaFluor Yellow 690 antibodies
(552/690 nm)
NovaFluor Red 725 dye
NovaFluor Red 725 antibodies
(636/725 nm)
    NovaFluor Blue 610-70S dye
NovaFluor Blue 610-70S antibodies
(509/614 nm)
NovaFluor Yellow 700 dye
NovaFluor Yellow 700 antibodies
(552/700 nm)
NovaFluor Red 755 dye
NovaFluor Red 755 antibodies
(636/755 nm)
    NovaFluor Blue 660-40S dye
NovaFluor Blue 660-40S antibodies
(509/665 nm)
NovaFluor Yellow 730 dye
NovaFluor Yellow 730 antibodies
(552/731 nm)
 
    NovaFluor Blue 660-120S dye
NovaFluor Blue 660-120S antibodies
(509/665 nm)
NovaFluor Yellow 755 dye
NovaFluor Yellow 755 antibodies
(552/755 nm)
 
    NovaFluor Blue 690 dye
NovaFluor Blue 690 antibodies
(494/690 nm)
NovaFluor Yellow 810 dye*
NovaFluor Yellow 810 antibodies*
(551/813 nm)
 
    NovaFluor Blue 725 dye*
NovaFluor Blue 725 antibodies*
(492/725 nm)
   
    NovaFluor Blue 760 dye
NovaFluor Blue 760 antibodies
(490/764 nm)
   
    NovaFluor Blue 800 dye*
NovaFluor Blue 800 antibodies*
(493/806 nm)
   

*This NovaFluor dye fits in a spectral space that is currently not accessible by other spectral dyes.

Have an antibody that isn’t conjugated to a NovaFluor? Use our NovaFluor conjugation kits to create NovaFluor conjugates on-demand.

 

For more ultra violet and violet dye options explore Brilliant Ultra Violet™/Violet™ Polymer Dyes and Super Bright Polymer dyes.


Minimalized cross-laser excitation

Cross-laser excitation is a significant contributor to spillover in flow cytometry experiments. Some fluorophores have excitation curves that enable fluorescence on more than one laser, leading to excess spillover and consequent spreading error. These effects can reduce the maximum experiment complexity possible on any instrument. NovaFluor dyes are designed to minimize cross-laser excitation, thereby enabling the full potential of your flow cytometer.

Minimalized impact to compensation

Increasing panel complexity can lead to compensation-related background. NovaFluor dyes are designed to minimize impacts to compensation, making it easier to increase panel size and complexity with minimal impact to compensation.

Decreased spillover spread

Spillover spread is impacted by several factors including fluorophore emission-spectra overlap, antigen expression level, and cross-laser excitation. Fluorophores with high cross-laser excitation can increase spread to a level where a detector will no longer be usable due to excessive background.

Designed for panel expansion

NovaFluor dyes’ enhanced spectral characteristics make them excellent candidates for panel expansion with minimal impacts to spillover and consequent spreading error.

Unlock the full power of your instrument through the enhanced spectral properties of NovaFluor dyes. Narrow excitation spectra enable broader utilization of the blue and yellow-green lasers on many flow cytometers. In this example, we see the typical channel distribution of a 12-color panel involving traditional dyes compared to a 14-color panel achieved by incorporating NovaFluor dyes.

Table 1. Design of two multicolor flow cytometry panels showing panel expansion with NovaFluor dyes. Panel A is 12-conjugate panel using traditional conjugates and Panel B is a 14-conjugate panel employing NovaFluor conjugates. Top rows indicate detectors and filter bandwidths, which are grouped by excitation source in order of increasing wavelength. Surface antigens are reported with conjugated fluorophores indicated. Exchanges in fluorophores are highlighted by color, while unoccupied detectors are indicated by “Open”. For example, CD3 PerCP-Cyanine5.5 used in Panel 1 is replaced by CD3 NovaFluor Blue 610-70S in Panel 2.
 

Figure 4. Data from two multicolor flow cytometry panels showing panel expansion with NovaFluor dyes. Comparison of flow cytometry plots as shown in Table 1 with the 12-conjugate panel (A) and 14-conjugate panel (B). All plots were gated on singlet, then viability, and finally lymphocytes. In addition, specific plots were sub-gated on populations as indicated above. Note arrows indicating areas of increased spread for Panel 1 vs Panel 2. Human peripheral blood mononuclear cells were stained Fixable Viability Dye eFluor 506 (Cat. No. 65-0866-18) then blocked with Fc Receptor Binding Inhibitor Polyclonal Antibody (Cat. No. 14-9161-73) and finally stained with the antibody conjugates indicated in Table 1 in the presence of CellBlox Blocking Buffer (Cat. No. B001T06F01) and Brilliant Stain Buffer (Cat. No. 00-4409-75).

Invitrogen CellBlox Plus Blocking Buffer

Invitrogen CellBlox Plus Blocking Buffer is formulated for enhanced blocking of nonspecific binding of NovaFluor antibody conjugates to cells. It provides exceptional blocking of nonspecific interactions when compared to CellBlox Blocking Buffer. Use of CellBlox Blocking Plus Buffer requires minimal change to most flow cytometry staining protocols.

New discoveries and insights

Discover the latest updates, data insights, and educational content from NovaFlour. Stay informed, explore new experiments, and enhance your scientific journey with our helpful tips and stories.

Related products

NovaFluor Conjugation Kits

Do you have an antibody that isn’t conjugated to a NovaFluor? Use our NovaFluor conjugation kits to create NovaFluor conjugates on-demand.

Image featuring NovaFluor Conjugation Kits

NovaFluor CD4 Label Characterization Kits

NovaFluor CD4 label characterization kits are formulated to enable the testing of NovaFluor dyes as direct conjugates of CD4. They can be used to evaluate performance of NovaFluor dyes on flow cytometers.

NovaFluor CD4 Label Characterization Kits in focus in this image

CellBlox Plus Blocking Buffer

CellBlox Plus blocking buffer is formulated to block nonspecific binding of NovaFluor dyes. It is a non-antibody blocking solution and should be utilized with NovaFluor dyes for labeling of any cell type.

CellBlox Plus Blocking Buffer in focus in this image.

Image displaying LIVE/DEAD Fixable Viability Dyes.

LIVE/DEAD fixable viability dyes are fixable viability dyes that help ensure accurate assessment of cell viability in samples after fixation and/or permeabilization.


Resources

FREE—Flow Cytometry Panel Design Service and Panel Builder Tool

Our scientists can design panels for you as many times you need—free of charge, no product purchase needed.

Panel design service and panel builder tool

Fluorescence SpectraViewer

Assess the spectral compatibility of dyes and probes for experiments that utilize fluorescence detection techniques.

Fluorescence SpectraViewer

Cy™ is a trademark or registered trademark of GE Healthcare. 

Not for resale. Super Bright Polymer Dyes are sold under license from Becton, Dickinson and Company. 

Brilliant Ultra Violet™ and Brilliant Violet™ are trademarks or registered trademarks of Becton, Dickinson and Company or its affiliates, and is used under license. 

 

For Research Use Only. Not for use in diagnostic procedures.