Acclaim™ AmG C18 HPLC Columns
Actual product may vary
Thermo Scientific™
Acclaim™ AmG C18 HPLC Columns
Meet today’s demands for aminoglycoside antibiotic analyses, including drug purity characterization & quantification. They have unique tolerance to harsh conditions.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberParticle SizeDiameter (Metric)Length (Metric)
0887553 μm3 mm150 mm
0887533 μm2.1 mm150 mm
0887573 μm4.6 mm150 mm
0887543 μm2.1 mm10 mm
0887563 μm3 mm10 mm
0887583 μm4.6 mm10 mm
6 Options
Catalog number 088755
Price (USD)/ Each
-
Particle Size:
3 μm
Diameter (Metric):
3 mm
Length (Metric):
150 mm
Get a high-performance, reversed-phase columns for aminoglycoside analysis. The robust and rugged Thermo Scientific™ Acclaim™ AmG C18 HPLC column provides exceptional tolerance required for aminoglycosides ion-pairing chromatographic separations. These silica-based C18 columns are optimized for various aminoglycoside antibiotic analyses, including drug purity characterization and quantification, therapeutic drug monitoring, and residual control testing in different matrices. These columns are stable at low pH, high temperature, organic solvents, and aqueous mobile phases.
Highly Stable for Aminoglycoside Analyses

The Acclaim AmG C18 column is specifically designed for ion-pairing reversed-phase HPLC (IP-RPLC) analysis of aminoglycoside antibiotics using volatile perfluorinated carboxylic acids as the ion-pairing reagent, such as 100 mM trifluoroacetic acid (TFA). The Acclaim AmG C18 stationary phase is based on a proprietary C18 bonding technology that provides extremely high stability towards acidic conditions. This specialty column exhibits excellent selectivity and high resolution for the aminoglycoside antibiotics analysis. In addition, it is easy to use because simple aqueous mobile phase (e.g. 100 mM TFA) without organic solvent and pH adjusting buffer is sufficient in most cases.

  • Excellent selectivity for aminoglycosides
  • Superior tolerance towards acidic conditions
  • High efficiency and throughput
  • Ease of use

The column can be used with UV, CAD, ELSD detectors

Specifications
Column FormatAnalytical Column
Diameter (Metric)3 mm
Flow Rate0.425 mL/min
Length (Metric)150 mm
Max. Pressure8000 psi (550 bar)
Particle Size3 μm
pH0.5 to 10
Pore Size120 Å
Temperature<80°C
USP TypeL1
Stationary PhaseC18
Product LineAcclaim
Packing MaterialSpherical, High Purity Silica
Column TypeAminoglycoside Analysis
PhaseReversed Phase
Unit SizeEach