Vanquish™ Charger Module
Vanquish™ Charger Module
Thermo Scientific™

Vanquish™ Charger Module

Increase sample capacity for extra-long unattended operation with an intelligent robotic that automates sample loading in the Thermo Scientific™ Vanquish™ UHPLC system.
Have Questions?
Catalog number VH-A90-A
Price (ARS)/ Each
-
Description:
Barcode reading: <ul> <li>Empty shelf level detection</li> <li>Rack/well plate verification</li> <li>Inventory management</li> </ul>
Weight (Metric):
<35 kg
PC Connection:
USB 2.0

Employ an intelligent robotic that is fully integrated into the Thermo Scientific™ Vanquish™ UHPLC system with the Vanquish Charger module. With a capacity of 8832 samples (23 well plates), the Charger module automates sample loading into the Vanquish system for extra-long unattended operation. Environmental controls ensure reliable sample protection. A barcode reader automatically inventories each plate or rack within the device every time the door is closed, allowing users to add samples at anytime even while the Vanquish UHPLC system is in operation.

View HPLC/UHPLC resources

Huge sample capacity, reliable sample protection, intelligent
  • Monitor and manage an inventory of up to 9 sample racks, deep well plates, or 20 shallow well plates (15mm height) in SBS format
  • Take advantage of maximum sample integrity by innovative air-stream cooling, even in challenging environments
  • Gain full inventory management via barcode reading with empty shelf level detection and rack/well plate verification
  • Enjoy a familiar control environment with full integration into Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System (CDS) software
Specifications
DescriptionBarcode reading: <ul> <li>Empty shelf level detection</li> <li>Rack/well plate verification</li> <li>Inventory management</li> </ul>
TypeVanquish Charger Without Shelf and Racks
GLP FeaturesAll System Parameters Logged in The Chromeleon Chromatography Data System Audit Trail.
PC ConnectionUSB 2.0
Safety FeaturesRack/Plate Detection Sensor, Magnetic Door Lock, Door Status Detection
Temperature Range4°C to 40°C (≥22 K Below Ambient (at <80% RH); Accuracy -2°C to +2°C (at 25°C, 50% RH); Stability ±0.5°C (at 25°C, 50% RH))
Overall Width (English)13.3 in.
Overall Width (Metric)339 mm
Overall Height (English)29.5 in.
Overall Height (Metric)750 mm
Overall Depth (English)24.4 in.
Overall Depth (Metric)650 mm
Weight (English)77.2 lb.
Weight (Metric)<35 kg
Voltage100-240 V AC, 50/60 Hz, Max. 350 W
Unit SizeEach