Thermo Scientific™

FHT 1388 S Modular Radiation Portal Monitors

Catalog number: 4254982
Thermo Scientific™

FHT 1388 S Modular Radiation Portal Monitors

Catalog number: 4254982

Thermo Scientific™ FHT 1388 S Modular Radiation Portal Monitor is a highly sensitive and highly reliable system for automatic and continuous radioactivity detection. It provides continuous radiation monitoring for moving trains and trucks, borders, and other crossing points.

 
Catalog Number
4254982
Unit Size
Each
Detectors
2 panels standard supply (max. 8 panels possible)
Detection Volume
12 L (per panel)
Radiation Detector Module
Horizontal orientation
Price (EUR)
Full specifications
Detector TypePlastic Scintillation
Power Requirements110 to 240 VAC, 50 to 65 Hz
Product TypeRadiation Portal Monitor
System Control UnitWindows 7 based Rugged Controller
Radiation Detector ModuleHorizontal orientation
Detection Volume12 L (per panel)
User InterfaceWindows 7 based Controller with SGS2.EXE Software
Radiation TypeGamma
Description4254982
Detection Surface Area0.24 m² (per one panel)
Display Type17 in. monitor
Relative Humidity10% to 90%, Non-Condensing
Temperature (English) OperatingOperator's Room: 32°F to 104°F; Detector Array: -13°F to +122°F
Temperature (Metric) OperatingOperator's Room: 0°C to 40°C; Detector Array: -25°C to +50°C
AlarmsGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel
Certifications/ComplianceQuality ISO 9001 certified; CE marking
Data MemoryStorage of every scan on hard drive possible
Detectors2 panels standard supply (max. 8 panels possible)
Energy Rangelowest threshold approx. 30 keV
False Alarm Ratetypically less then 1:10000
Measurement Time200 msec.
Sensitivity˜60000cps/μSv/h (Cs-137) per panel
Unit SizeEach
Catalog Number
Unit Size
Each
Detectors
2 panels standard supply (max. 8 panels possible)
Detection Volume
25 L (per panel)
Radiation Detector Module
Horizontal orientation
Price (EUR)
Full specifications
Detector TypePlastic Scintillation
Power Requirements110 to 240 VAC, 50 to 65 Hz
Product TypeRadiation Portal Monitor
System Control UnitWindows 7 based Rugged Controller
Radiation Detector ModuleHorizontal orientation
Detection Volume25 L (per panel)
User InterfaceWindows 7 based Controller with SGS2.EXE Software
Radiation TypeGamma
Description4254959
Detection Surface Area0.5 m² (per one panel)
Display Type17 in. monitor
Relative Humidity10% to 90%, Non-Condensing
Temperature (English) OperatingOperator's Room: 32°F to 104°F; Detector Array: -13°F to +122°F
Temperature (Metric) OperatingOperator's Room: 0°C to 40°C; Detector Array: -25°C to +50°C
AlarmsGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel
Certifications/ComplianceQuality ISO 9001 certified; CE marking
Data MemoryStorage of every scan on hard drive possible
Detectors2 panels standard supply (max. 8 panels possible)
Energy Rangelowest threshold approx. 30 keV
False Alarm Ratetypically less then 1:10000
Measurement Time200 msec.
Sensitivity˜120000cps/μSv/h (Cs-137) per panel
Unit SizeEach
Catalog Number
Unit Size
Each
Detectors
4 panels standard supply (max. 8 panels possible)
Detection Volume
12 L (per panel)
Radiation Detector Module
Horizontal orientation
Price (EUR)
Full specifications
Detector TypePlastic Scintillation
Power Requirements110 to 240 VAC, 50 to 65 Hz
Product TypeRadiation Portal Monitor
System Control UnitWindows 7 based Rugged Controller
Radiation Detector ModuleHorizontal orientation
Detection Volume12 L (per panel)
User InterfaceWindows 7 based Controller with SGS2.EXE Software
Radiation TypeGamma
Description425495904
Detection Surface Area0.5 m² (per one panel)
Display Type17 in. monitor
Relative Humidity10% to 90%, Non-Condensing
Temperature (English) OperatingOperator's Room: 32°F to 104°F; Detector Array: -13°F to +122°F
Temperature (Metric) OperatingOperator's Room: 0°C to 40°C; Detector Array: -25°C to +50°C
AlarmsGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel
Certifications/ComplianceQuality ISO 9001 certified; CE marking
Data MemoryStorage of every scan on hard drive possible
Detectors4 panels standard supply (max. 8 panels possible)
Energy Rangelowest threshold approx. 30 keV
False Alarm Ratetypically less then 1:10000
Measurement Time200 msec.
Sensitivity˜120000cps/μSv/h (Cs-137) per panel
Unit SizeEach
Catalog Number
Unit Size
Each
Detectors
2 panels standard supply (max. 8 panels possible)
Detection Volume
12 L (per panel)
Radiation Detector Module
Vertical orientation
Price (EUR)
Full specifications
Detector TypePlastic Scintillation
Power Requirements110 to 240 VAC, 50 to 65 Hz
Product TypeRadiation Portal Monitor
System Control UnitWindows 7 based Rugged Controller
Radiation Detector ModuleVertical orientation
Detection Volume12 L (per panel)
User InterfaceWindows 7 based Controller with SGS2.EXE Software
Radiation TypeGamma
Description425495903
Detection Surface Area0.5 m² (per one panel)
Display Type17 in. monitor
Relative Humidity10% to 90%, Non-Condensing
Temperature (English) OperatingOperator's Room: 32°F to 104°F; Detector Array: -13°F to +122°F
Temperature (Metric) OperatingOperator's Room: 0°C to 40°C; Detector Array: -25°C to +50°C
AlarmsGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel
Certifications/ComplianceQuality ISO 9001 certified; CE marking
Data MemoryStorage of every scan on hard drive possible
Detectors2 panels standard supply (max. 8 panels possible)
Energy Rangelowest threshold approx. 30 keV
False Alarm Ratetypically less then 1:10000
Measurement Time200 msec.
Sensitivity˜120000cps/μSv/h (Cs-137) per panel
Unit SizeEach
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeDetectorsDetection VolumeRadiation Detector ModulePrice (EUR)
4254982Full specifications
Each2 panels standard supply (max. 8 panels possible)12 L (per panel)Horizontal orientationRequest A Quote
Detector TypePlastic Scintillation
Power Requirements110 to 240 VAC, 50 to 65 Hz
Product TypeRadiation Portal Monitor
System Control UnitWindows 7 based Rugged Controller
Radiation Detector ModuleHorizontal orientation
Detection Volume12 L (per panel)
User InterfaceWindows 7 based Controller with SGS2.EXE Software
Radiation TypeGamma
Description4254982
Detection Surface Area0.24 m² (per one panel)
Display Type17 in. monitor
Relative Humidity10% to 90%, Non-Condensing
Temperature (English) OperatingOperator's Room: 32°F to 104°F; Detector Array: -13°F to +122°F
Temperature (Metric) OperatingOperator's Room: 0°C to 40°C; Detector Array: -25°C to +50°C
AlarmsGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel
Certifications/ComplianceQuality ISO 9001 certified; CE marking
Data MemoryStorage of every scan on hard drive possible
Detectors2 panels standard supply (max. 8 panels possible)
Energy Rangelowest threshold approx. 30 keV
False Alarm Ratetypically less then 1:10000
Measurement Time200 msec.
Sensitivity˜60000cps/μSv/h (Cs-137) per panel
Unit SizeEach
4254959Full specifications
Each2 panels standard supply (max. 8 panels possible)25 L (per panel)Horizontal orientationRequest A Quote
Detector TypePlastic Scintillation
Power Requirements110 to 240 VAC, 50 to 65 Hz
Product TypeRadiation Portal Monitor
System Control UnitWindows 7 based Rugged Controller
Radiation Detector ModuleHorizontal orientation
Detection Volume25 L (per panel)
User InterfaceWindows 7 based Controller with SGS2.EXE Software
Radiation TypeGamma
Description4254959
Detection Surface Area0.5 m² (per one panel)
Display Type17 in. monitor
Relative Humidity10% to 90%, Non-Condensing
Temperature (English) OperatingOperator's Room: 32°F to 104°F; Detector Array: -13°F to +122°F
Temperature (Metric) OperatingOperator's Room: 0°C to 40°C; Detector Array: -25°C to +50°C
AlarmsGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel
Certifications/ComplianceQuality ISO 9001 certified; CE marking
Data MemoryStorage of every scan on hard drive possible
Detectors2 panels standard supply (max. 8 panels possible)
Energy Rangelowest threshold approx. 30 keV
False Alarm Ratetypically less then 1:10000
Measurement Time200 msec.
Sensitivity˜120000cps/μSv/h (Cs-137) per panel
Unit SizeEach
425495904Full specifications
Each4 panels standard supply (max. 8 panels possible)12 L (per panel)Horizontal orientationRequest A Quote
Detector TypePlastic Scintillation
Power Requirements110 to 240 VAC, 50 to 65 Hz
Product TypeRadiation Portal Monitor
System Control UnitWindows 7 based Rugged Controller
Radiation Detector ModuleHorizontal orientation
Detection Volume12 L (per panel)
User InterfaceWindows 7 based Controller with SGS2.EXE Software
Radiation TypeGamma
Description425495904
Detection Surface Area0.5 m² (per one panel)
Display Type17 in. monitor
Relative Humidity10% to 90%, Non-Condensing
Temperature (English) OperatingOperator's Room: 32°F to 104°F; Detector Array: -13°F to +122°F
Temperature (Metric) OperatingOperator's Room: 0°C to 40°C; Detector Array: -25°C to +50°C
AlarmsGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel
Certifications/ComplianceQuality ISO 9001 certified; CE marking
Data MemoryStorage of every scan on hard drive possible
Detectors4 panels standard supply (max. 8 panels possible)
Energy Rangelowest threshold approx. 30 keV
False Alarm Ratetypically less then 1:10000
Measurement Time200 msec.
Sensitivity˜120000cps/μSv/h (Cs-137) per panel
Unit SizeEach
425495903Full specifications
Each2 panels standard supply (max. 8 panels possible)12 L (per panel)Vertical orientationRequest A Quote
Detector TypePlastic Scintillation
Power Requirements110 to 240 VAC, 50 to 65 Hz
Product TypeRadiation Portal Monitor
System Control UnitWindows 7 based Rugged Controller
Radiation Detector ModuleVertical orientation
Detection Volume12 L (per panel)
User InterfaceWindows 7 based Controller with SGS2.EXE Software
Radiation TypeGamma
Description425495903
Detection Surface Area0.5 m² (per one panel)
Display Type17 in. monitor
Relative Humidity10% to 90%, Non-Condensing
Temperature (English) OperatingOperator's Room: 32°F to 104°F; Detector Array: -13°F to +122°F
Temperature (Metric) OperatingOperator's Room: 0°C to 40°C; Detector Array: -25°C to +50°C
AlarmsGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel
Certifications/ComplianceQuality ISO 9001 certified; CE marking
Data MemoryStorage of every scan on hard drive possible
Detectors2 panels standard supply (max. 8 panels possible)
Energy Rangelowest threshold approx. 30 keV
False Alarm Ratetypically less then 1:10000
Measurement Time200 msec.
Sensitivity˜120000cps/μSv/h (Cs-137) per panel
Unit SizeEach
Showing 4 of 4
The modular system adapts to different needs, allowing for a scalable operation dependent upon the types of traffic moving through the portal.
  • Large area plastic scintillation detectors for Γ radiation detection with data transfer via RS 485 from the detector array to the operators room up to 1000mUV-stabilized PE panel housing stays corrosion free even under demanding conditions
  • Low energetic radiation can penetrate PE material easily; not shielded from the sensitive large area gamma radiation detector
  • Immediate separation between NORM and artificial radiation through NBR (Natural Background Rejection) technology
  • Optional moderated He3 counting tube Neutron radiation detectors
  • Effective false alarm suppression through automatic background radiation learning and SIGMA alarm threshold setting
  • ADF (Advanced Digital Filter), an intelligent ratemeter function with a self adjusting time constant, providing automatic adaption to the velocity of a moving source or detector and to the variable intensity of radiation
  • Recognition of objects plus speed alarm triggering
  • Control of traffic lights, audible alarm indication via horn or visible via alarm lights
  • Windows™ XP based controller model FHT 8000 with 32 bit SGS2 software package
  • Automated protocol printing also on a network printer

Recommended for:

The FHT 1388 is a highly sensitive and highly reliable system for automatic and continuous radioactivity detection and is applied for:

  • Checking cargoes on trucks, rail cars and ships
  • Prevention of smuggling and accidental transport
  • Waste monitoring with separate alarm thresholds for artificial and natural radiation

Our systems are in use worldwide in:

  • Steel plants
  • Scrap yards
  • Waste incinerators
  • Border transitions
  • Harbours, airports
  • Nuclear power plants

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text