| 840-299000 | Full specifications | Each | Beckman-style cell holder | GENESYS 140/150/180, BioMate 160 Spectrophotometers | Beckman-style short microcells | Request A Quote |
Description | Beckman-style cell holder | Type | Beckman-style Cell Holder | For Use With (Equipment) | GENESYS 140/150/180, BioMate 160 Spectrophotometers | Holds | Beckman-style short microcells | Unit Size | Each |
|
| 840-298900 | Full specifications | Each | Standard 10mm single-cell holder | GENESYS 140/150/180, BioMate 160 Spectrophotometers | 10 mm cuvette (1) | Request A Quote |
Description | Standard 10mm single-cell holder | Type | Single Cell Sample Holder | For Use With (Application) | Replaces the standard cell holder shipped with the instrument. | For Use With (Equipment) | GENESYS 140/150/180, BioMate 160 Spectrophotometers | Holds | 10 mm cuvette (1) | Unit Size | Each |
|
| 840-303100 | Full specifications | Each | Long path cylindrical cell holder | GENESYS 140/150/180, BioMate 160 Spectrophotometers | 5 mm to 100 mm cylindrical cuvette (1) | Request A Quote |
Description | Long path cylindrical cell holder | Type | Long Path Cell Holder | For Use With (Application) | Measurements of gases and select older standard methods that call specifically for cylindrical cells | For Use With (Equipment) | GENESYS 140/150/180, BioMate 160 Spectrophotometers | Holds | 5 mm to 100 mm cylindrical cuvette (1) | Shape | Cylindrical | Unit Size | Each |
|
| 840-303200 | Full specifications | Each | Sample holder for film/filter accommodates filters/lenses up to 50 mm long, 80mm tall and 10mm thick. Comes assembled in a removable sample compartment liner. | GENESYS 140/150/180, BioMate 160 Spectrophotometers | Filter/lenses up to 50 mm long x 80 mm tall x 10 mm thick. Minimum filter size 18 mm. | Request A Quote |
Description | Sample holder for film/filter accommodates filters/lenses up to 50 mm long, 80mm tall and 10mm thick. Comes assembled in a removable sample compartment liner. | Type | Sample Holder for Film/Filter | For Use With (Application) | Measuring transmitting solid samples such as glass or plastic panels, optical filters and specialty films on glass or plastic substrates. | For Use With (Equipment) | GENESYS 140/150/180, BioMate 160 Spectrophotometers | Holds | Filter/lenses up to 50 mm long x 80 mm tall x 10 mm thick. Minimum filter size 18 mm. | Unit Size | Each |
|
| 840-303300 | Full specifications | Each | Disposable microcell holder | GENESYS 140/150/180, BioMate 160 Spectrophotometers | Microcells disposable 50 μL plastic Uvettes™ | Request A Quote |
Description | Disposable microcell holder | Type | Disposable Microcell Holder | For Use With (Equipment) | GENESYS 140/150/180, BioMate 160 Spectrophotometers | Holds | Microcells disposable 50 μL plastic Uvettes™ | Unit Size | Each |
|
| 840-303800 | Full specifications | Each | Long path rectangular cell holder | GENESYS 140/150/180, BioMate 160 Spectrophotometers | 10 mm to 100 mm cuvette (1) | Request A Quote |
Description | Long path rectangular cell holder | Type | Long Path Cell Holder | For Use With (Application) | Measurements of solutions with low absorbance values | For Use With (Equipment) | GENESYS 140/150/180, BioMate 160 Spectrophotometers | Holds | 10 mm to 100 mm cuvette (1) | Shape | Rectangular | Unit Size | Each |
|
| 335079-000 | Full specifications | Each | Thermostatted rectangular cell holder | SPECTRONIC 200 and GENESYS 30/40/50 Spectrophotometers | Square 10 mm Pathlength Cuvette | Request A Quote |
Description | Thermostatted rectangular cell holder | Type | Single Cell Sample Holder | For Use With (Equipment) | SPECTRONIC 200 and GENESYS 30/40/50 Spectrophotometers | Holds | Square 10 mm Pathlength Cuvette | Use | Use with Accessory kit (840-278200) | Unit Size | Each |
|
| 335917-000 | Full specifications | Each | Adjustable filter holder | GENESYS 30/40/50 Spectrophotometers | Filters up to 10 mm thick | Request A Quote |
Description | Adjustable filter holder | Type | Individual Adjustable Filter Holder | For Use With (Application) | Measuring transmittance of thin solids, filters and glass or plastic test coupons. Supports filters as small as 10 mm | For Use With (Equipment) | GENESYS 30/40/50 Spectrophotometers | Holds | Filters up to 10 mm thick | Required Accessories | Baseplate for accessory mounting | Unit Size | Each |
|
| 840-277-500 also known as 840-277500 | Full specifications | Each | Test tube and vial holder accommodating 12 mm diameter up to 25 mm diameter test tubes and vials | GENESYS 30/40/50 Spectrophotometers | 12 mm to 25 mm diameter test tubes and vials | Request A Quote |
Description | Test tube and vial holder accommodating 12 mm diameter up to 25 mm diameter test tubes and vials | Type | Test Tube and Vial Holder | For Use With (Application) | Colorimetric/spectroscopic measurements in test tube cuvettes. OD600 measurements for cell growth monitoring in tubes. Monitoring cell growth in nephelo-culture flasks. Measurements in 16 mm screw-cap vials | For Use With (Equipment) | GENESYS 30/40/50 Spectrophotometers | Holds | 12 mm to 25 mm diameter test tubes and vials | Includes | One cuvette holder built into a sample compartment tray. Snaps into place magnetically. No tools required. | Unit Size | Each |
|
| 840-277600 | Full specifications | Each | Test-tube cap covers test-tubes up to 15 cm/6 inches tall to allow measurements while the sample compartment lid is open. | GENESYS 30/40/50 Spectrophotometers | Tall tubes and vials (lid open) | Request A Quote |
Description | Test-tube cap covers test-tubes up to 15 cm/6 inches tall to allow measurements while the sample compartment lid is open. | Type | Test Tube Cap | For Use With (Application) | Measurements in 6 in. tall test-tubes, especially in coal mining and agricultural applications. | For Use With (Equipment) | GENESYS 30/40/50 Spectrophotometers | Holds | Tall tubes and vials (lid open) | Includes | One cap to cover a tall test tube. | Required Accessories | Requires 840-277500 Test-Tube Holder | Unit Size | Each |
|