Exceed experimental expectation and versatility with recommended MultiOmics, Structural Biology, and BioPharma configurations of the Thermo Scientific™ Orbitrap Ascend Editions Tribrid™ Mass Spectrometer. Each Edition provides a tailored configuration of options for each application space, simplifying your decisions and streamlining your research. Characterize even the largest biopharmaceuticals and protein complexes with the Native MS option, which extends the Orbitrap mass range up to m/z 16,000 and new quadrupole isolation up to m/z 8,000. Unlock the potential of alternate fragmentation techniques to decipher the most challenging molecules.

 
Catalog Number
B51003849
Unit Size
Each
Description
Orbitrap Ascend BioPharma Tribrid Mass Spectrometer with PTCR, ETD, UVPD, and Native MS recommended options
Price (HKD)
Full specifications
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range40 to 6000 m/z (with recommended options: Mass Range up to 16,000 m/z)
Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity SwitchingOne full experimental cycle acquired in < 1.1 seconds
DescriptionOrbitrap Ascend BioPharma Tribrid Mass Spectrometer with PTCR, ETD, UVPD, and Native MS recommended options
Dimensions (D x W x H)34 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Orbitrap Ascend Tribrid mass spectrometer, Standard
Price (HKD)
Full specifications
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, Standard
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Orbitrap Ascend MultiOmics Tribrid Mass Spectrometer with ETD and IC recommended options
Price (HKD)
Full specifications
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range40 to 6000 m/z
Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity SwitchingOne full experimental cycle acquired in < 1.1 seconds
DescriptionOrbitrap Ascend MultiOmics Tribrid Mass Spectrometer with ETD and IC recommended options
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Orbitrap Ascend Structural Biology Tribrid Mass Spectrometer with IC/ETD, PTCR, and Native MS recommended options
Price (HKD)
Full specifications
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range40 to 6000 m/z (with recommended options: Mass Range up to 16,000 m/z)
Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity SwitchingOne full experimental cycle acquired in < 1.1 seconds
DescriptionOrbitrap Ascend Structural Biology Tribrid Mass Spectrometer with IC/ETD, PTCR, and Native MS recommended options
Dimensions (D x W x H)35 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeDescriptionPrice (HKD)
B51003849Full specifications
EachOrbitrap Ascend BioPharma Tribrid Mass Spectrometer with PTCR, ETD, UVPD, and Native MS recommended optionsRequest A Quote
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range40 to 6000 m/z (with recommended options: Mass Range up to 16,000 m/z)
Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity SwitchingOne full experimental cycle acquired in < 1.1 seconds
DescriptionOrbitrap Ascend BioPharma Tribrid Mass Spectrometer with PTCR, ETD, UVPD, and Native MS recommended options
Dimensions (D x W x H)34 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
FSN06-10000Full specifications
EachOrbitrap Ascend Tribrid mass spectrometer, StandardRequest A Quote
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range

m/z 40-6000

Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity Switching

One full experimental cycle acquired in <1.1 seconds

DescriptionOrbitrap Ascend Tribrid mass spectrometer, Standard
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
B51003847Full specifications
EachOrbitrap Ascend MultiOmics Tribrid Mass Spectrometer with ETD and IC recommended optionsRequest A Quote
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range40 to 6000 m/z
Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity SwitchingOne full experimental cycle acquired in < 1.1 seconds
DescriptionOrbitrap Ascend MultiOmics Tribrid Mass Spectrometer with ETD and IC recommended options
Dimensions (D x W x H)32 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
B51003848Full specifications
EachOrbitrap Ascend Structural Biology Tribrid Mass Spectrometer with IC/ETD, PTCR, and Native MS recommended optionsRequest A Quote
TypeOrbitrap LC-MS
Dynamic Range> 5000 within a single scan
Mass Range40 to 6000 m/z (with recommended options: Mass Range up to 16,000 m/z)
Mass Accuracy< 3 ppm RMS using external calibration
Scan RatesUp to 45 Hz
Polarity SwitchingOne full experimental cycle acquired in < 1.1 seconds
DescriptionOrbitrap Ascend Structural Biology Tribrid Mass Spectrometer with IC/ETD, PTCR, and Native MS recommended options
Dimensions (D x W x H)35 x 50 x 28 in. (81 x 127 x 70 cm)
Weight (Metric)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
Showing 4 of 4

With three unique fit-for-purpose Editions that are tailored for MultiOmics; Structural Biology; and BioPharma application areas, Orbitrap Ascend Editions Tribrid mass spectrometers ensure high-quality data acquisition. Whether you're focused on multiplexed quantitative proteomics, metabolomics, lipidomics or glycomics, small molecule-based pharmaceuticals or biotherapeutics, single-cell or deciphering higher-order protein structures; these instruments are uniquely suited to your needs.

  • Native MS option: Orbitrap extended mass range up to m/z 16000 and new quadrupole isolation up to m/z 8000 for improved selectivity and MSn sensitivity of macromolecules.
  • PTCR option: Reduce m/z spectrum complexity to enhance proteoform characterization at MS1 and MS2 levels.
  • UVPD option: Improved fragmentation for top-down proteomics, oligonucleotides, lipidomics, and other analytes
  • Easy-ETD option: Achieve high sequence coverage of proteins, including site localization of labile PTMs.
  • EASY-IC ion source option: Obtain sub-1ppm mass accuracy with internal calibration.
  • Dual IRMs: Confidently identify more molecules with two ion-routing multiples to increase scan rate and sensitivity.
  • Real-Time Library Search: Provides higher confidence identifications for peptide or small molecule analysis using MSn.
  • Auto-Ready ion source: Spend less time on instrument setup with a new dedicated source for autocalibration.
  • Pre-built method templates: Optimized methods for each Edition system, covering diverse applications.
  • Dry-Pump: Environmentally friendly, oil-free dry pump is standard to decrease maintenance while providing leak-free vacuum performance.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text