Dionex™ IonPac™ AS31 Analytical and Guard Columns

產品號碼: 303147
Have Questions?
Thermo Scientific™

Dionex™ IonPac™ AS31 Analytical and Guard Columns

產品號碼: 303147
Have Questions?

Achieve faster separation of haloacetic acids (HAAs), bromate, and dalapon in drinking water prior to detection with ion chromatography (IC) and mass spectrometry (MS) with the new Thermo Scientific™ Dionex™ IonPac™ AS31 column. Specifically designed for fast analysis, the Dionex IonPac AS31 provides approximately 39% shorter run times relative to the Dionex IonPac AS24, reducing U.S. EPA Method 557 run time from 57 minutes to approximately 35 minutes. This new hydroxide-selective anion-exchange column has relatively high capacity to allow large loop injections for trace analysis (μg/L) without sample pre-treatment.

 
產品號碼
303147
Unit Size
Each
Column Type
Analytical Column
Length (Metric)
250 mm
Particle Size
6 μm
價格 (HKD)
完整規格
Anion Exchange Capacity116 μeq
Column ConstructionPEEK
Column TypeAnalytical Column
Crosslinking55% DVB
Column Capacity116 μeq
Column ChemistryHydroxide
Flow Rate0.3 mL/min.
For Use With (Application)Anion Exchange
For Use With (Equipment)Dionex IonPac AG31 Microbore Guard Column
HydrophobicityLow
Max. Pressure5000 psi (345 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% Organic Solvents (Acetonitrile, Methanol, 2-Propanol)
Particle Size6 μm
Stationary PhaseSuper Macroporous Resin
FormatMicrobore
Packing MaterialEthylvinylbenzene/Divinylbenzene
Length (Metric)250 mm
Diameter (Metric)2 mm
Unit SizeEach
產品號碼
Unit Size
Each
Column Type
Guard Column
Length (Metric)
50 mm
Particle Size
11 μm
價格 (HKD)
完整規格
Anion Exchange Capacity1.5 μeq
Column ConstructionPEEK
Column TypeGuard Column
Crosslinking55% DVB
Column Capacity1.5 μeq
Column ChemistryHydroxide
Flow Rate0.30 to 0.40 mL/min.
For Use With (Application)Anion Exchange
For Use With (Equipment)Dionex IonPac AS31 Microbore Analytical Column
HydrophobicityLow
Max. Pressure5000 psi (345 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% Organic Solvents (Acetonitrile, Methanol, 2-Propanol)
Particle Size11 μm
Stationary PhaseMicroporous Resin
FormatMicrobore
Packing MaterialEthylvinylbenzene/Divinylbenzene
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach
顯示 2 項,共 2 項
產品號碼規格Unit SizeColumn TypeLength (Metric)Particle Size價格 (HKD)
303147完整規格
EachAnalytical Column250 mm6 μm
Anion Exchange Capacity116 μeq
Column ConstructionPEEK
Column TypeAnalytical Column
Crosslinking55% DVB
Column Capacity116 μeq
Column ChemistryHydroxide
Flow Rate0.3 mL/min.
For Use With (Application)Anion Exchange
For Use With (Equipment)Dionex IonPac AG31 Microbore Guard Column
HydrophobicityLow
Max. Pressure5000 psi (345 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% Organic Solvents (Acetonitrile, Methanol, 2-Propanol)
Particle Size6 μm
Stationary PhaseSuper Macroporous Resin
FormatMicrobore
Packing MaterialEthylvinylbenzene/Divinylbenzene
Length (Metric)250 mm
Diameter (Metric)2 mm
Unit SizeEach
303148完整規格
EachGuard Column50 mm11 μm
Anion Exchange Capacity1.5 μeq
Column ConstructionPEEK
Column TypeGuard Column
Crosslinking55% DVB
Column Capacity1.5 μeq
Column ChemistryHydroxide
Flow Rate0.30 to 0.40 mL/min.
For Use With (Application)Anion Exchange
For Use With (Equipment)Dionex IonPac AS31 Microbore Analytical Column
HydrophobicityLow
Max. Pressure5000 psi (345 bar)
Solvent CompatibilitypH 0 to 14, 0 to 100% Organic Solvents (Acetonitrile, Methanol, 2-Propanol)
Particle Size11 μm
Stationary PhaseMicroporous Resin
FormatMicrobore
Packing MaterialEthylvinylbenzene/Divinylbenzene
Length (Metric)50 mm
Diameter (Metric)2 mm
Unit SizeEach
顯示 2 項,共 2 項
Superior Chromatographic Performance
  • Can meet or exceed the performance requirements of U.S. EPA Method 557.
  • High capacity (116 μeq/column) allows injection of complex matrices without overloading the column while maintaining excellent peak shapes for lower concentration analytes.
  • Requires no sample pre-treatment when determining haloacetic acids in high-ionic strength matrices.
  • Column selectivity has been optimized at an operating temperature of 15°C to ensure reproducible recovery for haloacetic acids.
Use with a High-Pressure IC system

A high-pressure IC system, such as the Thermo Scientific™ Dionex™ ICS-5000+ HPIC™ system or Dionex ICS-6000 HPIC system is required to operate this column under standard conditions.