Applied Biosystems™

POP-6™ Polymer for 3500 Dx/3500xL Dx Genetic Analyzers

產品號碼: 4393716
Applied Biosystems™

POP-6™ Polymer for 3500 Dx/3500xL Dx Genetic Analyzers

產品號碼: 4393716
產品號碼
4393716
包裝規格
384 samples
產品號碼
包裝規格
960 samples
產品號碼包裝規格價格 (HKD)
4393716384 samples與我們聯繫 ›
4393711960 samples與我們聯繫 ›
產品概覽
圖表
影片
建議
建議
文件
常見問題
引用資料與參考文獻
其他資訊
建議
3500 Dx Series POP-6™ Polymer is a separation matrix for the 3500 Dx⁄3500xL Dx genetic analyzers. It is conveniently offered in easy-to-use pouch packages in either 960- or 384-sample size formats.

Easy to Use
POP polymers are pre-formulated in a single-use pouch, which not only saves time but also ensures reliability and consistency.

Radio Frequency Identification (RFID) Label
RFID labels encode easy-to-track information such as part⁄lot number, samples remaining, and expiration dates (displayed on software dashboard).

Robust Formulation
POP polymers are formulated for a wide range of applications.

Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their defined quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.

Performance Optimized Polymer
This product is intended for in-vitro diagnostic use on the Applied Biosystems 3500 Dx Series Genetic Analyzers and is not validated for use with other systems or applications. Refer to the Applied Biosystems™ 3500 Dx⁄3500xL Dx Genetic Analyzer User Guide for further details.

規格

Capillary Length
50 cm, 36 cm
For Use With (Equipment)
3500xL Dx Genetic Analyzer, 3500 Dx Genetic Analyzer
For Use With (Application)
Fragment Analysis, Standard Sequencing
On Instrument Life Usage
Contains enough polymer for 384 samples; polymer is stable on instrument for 7 days
Product Line
POP-6™
Quantity
384 Samples
Shipping Condition
Wet Ice
Test Time
2 hrs for 50 cm capillary (long read), 1 hr for 36 cm capillary (std. seq.)

內容物與存放

Store the polymer pouch at 2-8°C until ready to use.
Note that expired pouches cannot be used on the instrument.

On-instrument life⁄usage

3500 Dx (8 capillary) Genetic Analyzer: lesser of 7 days or 384 samples or 60 injections

3500xL Dx (24 capillary) Genetic Analyzer: lesser of 7 days or 384 samples or 20 injections

The pouch includes additional polymer volume to accommodate both installation and a reasonable number of post-installation wizard operations such as bubble removal without affecting the number of samples⁄injections available.