Thermo Scientific™

Vanquish™ Diode Array Detectors and Multiple Wavelength Detectors

產品號碼: VH-D10-A
Thermo Scientific™

Vanquish™ Diode Array Detectors and Multiple Wavelength Detectors

產品號碼: VH-D10-A

Get the best performance, reliability, and flexibility in HPLC and UHPLC detection with Thermo Scientific™ Vanquish™ Diode Array Detectors (DAD) and Multiple Wavelength Detectors (MWD). These detectors offer excellent linearity and optimized noise performance, and feature an ultra-wide dynamic range to allow detection of highly concentrated main compounds alongside trace-level impurities.

In addition, the Vanquish DAD HL uses Thermo Scientific™ LightPipe™ technology to achieve the best signal-to-noise performance through a combination of low baseline noise, a very long light path, and minimal dispersion.

View HPLC/UHPLC resources

 
產品號碼
VH-D10-A
Unit Size
Each
Type
Diode Array Detector
Wavelength Range
190 to 680 nm
價格 (HKD)
完整規格
DescriptionVanquish Diode Array Detector HL
Data Collection Rate200 Hz Max.
Detection ModeUV-vis Detection (Up to 10 Channels)
Detector TypeSingle-Beam
TypeDiode Array Detector
Drift< 0.5 mAU/hour at 230nm
Flow Cell VolumeStandard, LightPipe flow cell, 10mm
High Sensitivity, Light Pipe flow cell, 60mm
LightPipe diagnostic cell
GLP FeaturesPredictive performance functions: lamp age and ignitions, lamp intensity degradation, leak detection, service monitoring period.
All system parameters logged in the Chromeleon CDS Audit Trail.
LampDeuterium lamp
Linearity< 5% at 2.0 AU (typically < 5% (at 2.5 AU))
Max. Cell Operating PressureLimit 6 MPa (60 bar, 870 psi)
Noise< ± 3 μAU (at 230 nm (standard flow cell, bandwidth: 4 nm, slit width: 4 nm; time constant: 2 s))
No. of Channels10 + 3D field
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
Photodiode Array1024 element
Safety FeaturesPower-up diagnostics of optics, cooling fans, motors and electronics. Leak detection and safe leak handling.
Slit Width1 mm, 2 mm, 4 mm, 8 nm
Spectral BandwidthPixel resolution: 0.5nm (average)
Optical resolution: 1nm (FWHM with 1nm slit width)
Temperature Range5 to 35°C; 20 to 80% RH (non-condensing)
Validation FunctionsInternal validation with holmium oxide filter
Wavelength Accuracy± 1 nm
Wavelength Range190 to 680 nm
Wavelength Repeatability± 0.1 nm
Dimensions (L x W x H)160 mm x 420 mm x 620 mm (6.3 in. x 16.5 in. x 24.4 in.)
Weight (Metric)17 kg
Electrical Requirements100–240 V AC, 50/60 Hz, max. 150 W/255 VA
Unit SizeEach
產品號碼
Unit Size
Each
Type
Diode Array Detector
Wavelength Range
190-800 nm
價格 (HKD)
完整規格
DescriptionVanquish™ Diode Array Detector CG
Data Collection Rate125 Hz Max.
Detection ModeUV-vis Detection (Up to 8 Channels)
Detector TypeSingle-Beam
TypeDiode Array Detector
PC ConnectionUSB 2.0; 3-port HUB to connect additional Vanquish modules
Wavelength Range190-800 nm
Dimension159 mm × 420 mm × 620 mm (6.3 in. × 16.5 in. × 24.4 in.)
Weight (Metric)16 kg
Voltage100-240 V AC, 50/60 Hz, max. 250 W/255 VA
Unit SizeEach
產品號碼
Unit Size
Each
Type
Multiple Wavelength Detector
Wavelength Range
190-800 nm
價格 (HKD)
完整規格
DescriptionVanquish™ Multiple Wavelength Detector CG
Data Collection Rate125 Hz Max.
Detection ModeUV-vis Detection (Up to 8 Channels)
Detector TypeSingle-Beam
TypeMultiple Wavelength Detector
PC ConnectionUSB 2.0; 3-port HUB to connect additional Vanquish modules
Wavelength Range190-800 nm
Dimension159 mm × 420 mm × 620 mm (6.3 in. × 16.5 in. × 24.4 in.)
Weight (Metric)16 kg
Voltage100-240 V AC, 50/60 Hz, max. 250 W/255 VA
Unit SizeEach
產品號碼
Unit Size
Each
Type
Diode Array Detector
Wavelength Range
190–800 nm
價格 (HKD)
完整規格
DescriptionVanquish Diode Array Detector FG
Data Collection Rate250 Hz Max.
Detection ModeUV-vis Detection (Up to 10 Channels)
Detector TypeSingle-Beam
TypeDiode Array Detector
Drift< 1 mAU/hour at 254 nm
Flow Cell VolumeStandard, path length 10 mm (13 μL, SST)
Standard, biocompatible, path length 10 mm (13 μL, PEEK)
Semi-analytical, path length 7 mm (5 μL, SST)
Semi-micro, pathlength 7 mm (2.5 μL, SST)
Semi-micro, biocompatible, path length 7 mm (2.5 μL, titanium)
Diagnostic cell
GLP FeaturesPredictive performance functions: lamp age and ignitions, lamp intensity degradation, leak detection, service monitoring period.
All system parameters logged in the Chromeleon CDS Audit Trail.
LampDeuterium lamp, tungsten lamp
Linearity< 5% at 2.2 AU (typically < 5% at 2.7 AU)
Max. Cell Operating PressureStandard biocompatible: 5 MPa (50 bar, 720 psi)
Other flow cells: 12 MPa (120 bar, 1740 psi)
Noise<± 6 μAU at 254 nm (standard flow cell, bandwidth: 4 nm, slit width: wide, time constant: 2 sec)
No. of Channels10 + 3D field
PC ConnectionUSB 2.0; 3-port HUB to connect further Vanquish modules
Photodiode Array1024 element
Safety FeaturesPower-up diagnostics of optics, cooling fans, motors and electronics. Leak detection and safe leak handling.
Slit WidthSettable: Wide, narrow
Spectral BandwidthPixel resolution: 0.6 nm (average)
Temperature Range5 to 35°C; 20 to 80% RH (non-condensing)
Validation FunctionsInternal validation with holmium oxide filter
Wavelength Accuracy± 1 nm
Wavelength Range190–800 nm
Wavelength Repeatability± 0.1 nm
Weight (Metric)16.3 kg
Electrical Requirements100–240 V AC, 50/60 Hz, max. 245 W / 255 VA
Unit SizeEach
顯示 4 項,共 4 項
產品號碼規格Unit SizeTypeWavelength Range價格 (HKD)
VH-D10-A完整規格
EachDiode Array Detector190 to 680 nm申請報價
DescriptionVanquish Diode Array Detector HL
Data Collection Rate200 Hz Max.
Detection ModeUV-vis Detection (Up to 10 Channels)
Detector TypeSingle-Beam
TypeDiode Array Detector
Drift< 0.5 mAU/hour at 230nm
Flow Cell VolumeStandard, LightPipe flow cell, 10mm
High Sensitivity, Light Pipe flow cell, 60mm
LightPipe diagnostic cell
GLP FeaturesPredictive performance functions: lamp age and ignitions, lamp intensity degradation, leak detection, service monitoring period.
All system parameters logged in the Chromeleon CDS Audit Trail.
LampDeuterium lamp
Linearity< 5% at 2.0 AU (typically < 5% (at 2.5 AU))
Max. Cell Operating PressureLimit 6 MPa (60 bar, 870 psi)
Noise< ± 3 μAU (at 230 nm (standard flow cell, bandwidth: 4 nm, slit width: 4 nm; time constant: 2 s))
No. of Channels10 + 3D field
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
Photodiode Array1024 element
Safety FeaturesPower-up diagnostics of optics, cooling fans, motors and electronics. Leak detection and safe leak handling.
Slit Width1 mm, 2 mm, 4 mm, 8 nm
Spectral BandwidthPixel resolution: 0.5nm (average)
Optical resolution: 1nm (FWHM with 1nm slit width)
Temperature Range5 to 35°C; 20 to 80% RH (non-condensing)
Validation FunctionsInternal validation with holmium oxide filter
Wavelength Accuracy± 1 nm
Wavelength Range190 to 680 nm
Wavelength Repeatability± 0.1 nm
Dimensions (L x W x H)160 mm x 420 mm x 620 mm (6.3 in. x 16.5 in. x 24.4 in.)
Weight (Metric)17 kg
Electrical Requirements100–240 V AC, 50/60 Hz, max. 150 W/255 VA
Unit SizeEach
VC-D11-A-01完整規格
EachDiode Array Detector190-800 nm申請報價
DescriptionVanquish™ Diode Array Detector CG
Data Collection Rate125 Hz Max.
Detection ModeUV-vis Detection (Up to 8 Channels)
Detector TypeSingle-Beam
TypeDiode Array Detector
PC ConnectionUSB 2.0; 3-port HUB to connect additional Vanquish modules
Wavelength Range190-800 nm
Dimension159 mm × 420 mm × 620 mm (6.3 in. × 16.5 in. × 24.4 in.)
Weight (Metric)16 kg
Voltage100-240 V AC, 50/60 Hz, max. 250 W/255 VA
Unit SizeEach
VC-D12-A-01完整規格
EachMultiple Wavelength Detector190-800 nm申請報價
DescriptionVanquish™ Multiple Wavelength Detector CG
Data Collection Rate125 Hz Max.
Detection ModeUV-vis Detection (Up to 8 Channels)
Detector TypeSingle-Beam
TypeMultiple Wavelength Detector
PC ConnectionUSB 2.0; 3-port HUB to connect additional Vanquish modules
Wavelength Range190-800 nm
Dimension159 mm × 420 mm × 620 mm (6.3 in. × 16.5 in. × 24.4 in.)
Weight (Metric)16 kg
Voltage100-240 V AC, 50/60 Hz, max. 250 W/255 VA
Unit SizeEach
VF-D11-A-01完整規格
EachDiode Array Detector190–800 nm申請報價
DescriptionVanquish Diode Array Detector FG
Data Collection Rate250 Hz Max.
Detection ModeUV-vis Detection (Up to 10 Channels)
Detector TypeSingle-Beam
TypeDiode Array Detector
Drift< 1 mAU/hour at 254 nm
Flow Cell VolumeStandard, path length 10 mm (13 μL, SST)
Standard, biocompatible, path length 10 mm (13 μL, PEEK)
Semi-analytical, path length 7 mm (5 μL, SST)
Semi-micro, pathlength 7 mm (2.5 μL, SST)
Semi-micro, biocompatible, path length 7 mm (2.5 μL, titanium)
Diagnostic cell
GLP FeaturesPredictive performance functions: lamp age and ignitions, lamp intensity degradation, leak detection, service monitoring period.
All system parameters logged in the Chromeleon CDS Audit Trail.
LampDeuterium lamp, tungsten lamp
Linearity< 5% at 2.2 AU (typically < 5% at 2.7 AU)
Max. Cell Operating PressureStandard biocompatible: 5 MPa (50 bar, 720 psi)
Other flow cells: 12 MPa (120 bar, 1740 psi)
Noise<± 6 μAU at 254 nm (standard flow cell, bandwidth: 4 nm, slit width: wide, time constant: 2 sec)
No. of Channels10 + 3D field
PC ConnectionUSB 2.0; 3-port HUB to connect further Vanquish modules
Photodiode Array1024 element
Safety FeaturesPower-up diagnostics of optics, cooling fans, motors and electronics. Leak detection and safe leak handling.
Slit WidthSettable: Wide, narrow
Spectral BandwidthPixel resolution: 0.6 nm (average)
Temperature Range5 to 35°C; 20 to 80% RH (non-condensing)
Validation FunctionsInternal validation with holmium oxide filter
Wavelength Accuracy± 1 nm
Wavelength Range190–800 nm
Wavelength Repeatability± 0.1 nm
Weight (Metric)16.3 kg
Electrical Requirements100–240 V AC, 50/60 Hz, max. 245 W / 255 VA
Unit SizeEach
顯示 4 項,共 4 項
Vanquish DAD features
  • Industry leading linearity with up to 2.7 AU
  • Reduced interfering refractive index and thermal effects means less baseline drift and more reliable peak integration.
  • Data acquisition at rates up to 250 Hz using up to 10 absorption channels and one spectral field delivers the best support of ultrafast separations.
  • Easy-to-use detector with intuitive user interaction, convenient flow cell and lamp usage tracking, and the integrated wavelength validation through holmium oxide filter.

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text