Thermo Scientific™

Vanquish™ Column Compartments

Catalog number: VH-C10-A-03
Thermo Scientific™

Vanquish™ Column Compartments

Catalog number: VH-C10-A-03

Control your separation temperature with confidence using Thermo Scientific™ Vanquish™ Column Compartments. The unique combination of active and/or passive eluent pre-heating and two column thermostatting modes—still and forced air—available in Vanquish Column Compartments H and C, ensures reliable matching of the eluent and column temperature for superior UHPLC performance and allows for easy LC method transfer. Vanquish Column Compartment N supports advanced low-flow applications as well as capillary and micro-flow direct injection applications in the Thermo Scientific™ Vanquish™ Neo UHPLC system.


View HPLC/UHPLC resources

 
Catalog Number
VH-C10-A-03
Unit Size
Each
Description
Vanquish Column Compartment H
For Use With (Equipment)
Vanquish Flex UHPLC System, Vanquish Horizon UHPLC System
Price (JPY)
Availability
***
Full specifications
DescriptionVanquish Column Compartment H
For Use With (Equipment)Vanquish Flex UHPLC System, Vanquish Horizon UHPLC System
TypeColumn Compartment
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Temperature Range5°C to 120°C
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Vanquish Column Compartment C
For Use With (Equipment)
Vanquish Core HPLC System
Price (JPY)
Availability
***
Full specifications
DescriptionVanquish Column Compartment C
For Use With (Equipment)Vanquish Core HPLC System
TypeColumn Compartment
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Temperature Range5°C to 85°C
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Vanquish Column Compartment N
For Use With (Equipment)
Vanquish Neo UHPLC System
Price (JPY)
Availability
***
Full specifications
DescriptionVanquish Column Compartment N
For Use With (Equipment)Vanquish Neo UHPLC System
TypeColumn Compartment
Column CapacityCoiled, fused silica columns, linear columns plus fitting with maximum length of 350 mm
Temperature RangeMin: 5 K above room temperature; Max: 80°C without valves installed or 60°C with Vanquish LD valves installed
Unit SizeEach
Showing 3 of 3
Catalog NumberSpecificationsUnit SizeDescriptionFor Use With (Equipment)Price (JPY)Availability
VH-C10-A-03Full specifications
EachVanquish Column Compartment HVanquish Flex UHPLC System, Vanquish Horizon UHPLC SystemRequest A Quote***
DescriptionVanquish Column Compartment H
For Use With (Equipment)Vanquish Flex UHPLC System, Vanquish Horizon UHPLC System
TypeColumn Compartment
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Temperature Range5°C to 120°C
Unit SizeEach
VC-C10-A-03Full specifications
EachVanquish Column Compartment CVanquish Core HPLC SystemRequest A Quote***
DescriptionVanquish Column Compartment C
For Use With (Equipment)Vanquish Core HPLC System
TypeColumn Compartment
Column Capacity2 x max, 300 mm w/pre-heater or guard column, Max. ID: 10 mm; 2 x max, 250 mm w/pre-heater and guard column, Max. ID: 10 mm
Temperature Range5°C to 85°C
Unit SizeEach
VN-C10-A-01Full specifications
EachVanquish Column Compartment NVanquish Neo UHPLC SystemRequest A Quote***
DescriptionVanquish Column Compartment N
For Use With (Equipment)Vanquish Neo UHPLC System
TypeColumn Compartment
Column CapacityCoiled, fused silica columns, linear columns plus fitting with maximum length of 350 mm
Temperature RangeMin: 5 K above room temperature; Max: 80°C without valves installed or 60°C with Vanquish LD valves installed
Unit SizeEach
Showing 3 of 3
Vanquish Column Compartments H and C offer:
  • Wide column temperature ranges with cooling down to 5 °C (max. 18 K below ambient)
  • Still-air thermostatting for minimum thermal mismatch by viscous heating for best possible efficiencies and resolution under UHPLC conditions
  • Forced-air thermostatting for fast thermal equilibration and highest flexibility, e.g., for method transfer from other instruments
  • Active eluent preheating and post-column cooling (Vanquish Column Compartment H only) for optimum separation control
  • Advanced workflows, such as Tandem LC and LC-MS, online SPE, trap and loop heart-cut 2D-LC with the installation of up to two optional switching valves
Vanquish Column Compartment N offers:
  • Passive pre-heating and forced-air thermostatting (column heating only)
  • Support for advanced low-flow applications as well as capillary and micro-flow direct injection applications with two optional low-dispersion switching valves