Remove inorganic solids, organics, bacteria and pyrogens from your water through the distillation process using Thermo Scientific™ Barnstead™ Classic Stills. Choose from bench or floor mounted models. Available in five capacities to meet your production needs, stills are constructed of copper and bronze with a pure tin coating. The inert nature of tin prevents leaching of contaminants into water. Portable stills allow for quick set-up, while floor model electric stills improve safety with over-temperature protection. Steam stills feature optional automatic controls for unattended operation.

 
Catalog Number
A1015-B-61
Unit Size
Each
Type
Electric
Output Flow Rate
5 gal./hr.
Electrical Requirements
240 V 50/60 Hz
Price (KRW)
Full specifications
Amperage57 A
Dimensions (L x W x H)14 x 35 x 77 in. (36 x 89 x 196 cm)
Electrical Requirements240 V 50/60 Hz
Frequency50/60 Hz
Phase1
Voltage240 V
Flow Rate5 gal./hr.
TypeElectric
Output Flow Rate5 gal./hr.
Model5 gal./hr. (240 V) Floor Electric with Stand
Height (English)77 in.
Height (Metric)196 cm
Width (English)35 in.
Width (Metric)89 cm
Cooling Flow Rate (Metric)151 L/hr.
Length (English)14 in.
Length (Metric)36 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
Catalog Number
Unit Size
Each
Type
Electric (Portable)
Output Flow Rate
0.5 gal./hr.
Electrical Requirements
120 V 50/60 Hz
Price (KRW)
Full specifications
Amperage12 A
Dimensions (L x W x H)10 x 21 x 19 in. (26 x 52 x 49 cm)
Electrical Requirements120 V 50/60 Hz
Frequency50/60 Hz
Phase1
Voltage120 V
Flow Rate0.5 gal./hr.
TypeElectric (Portable)
Output Flow Rate0.5 gal./hr.
Model0.5 gal./hr. Portable
Height (English)19 in.
Height (Metric)49 cm
Width (English)21 in.
Width (Metric)52 cm
Cooling Flow Rate (English)4 gal./hr.
Cooling Flow Rate (Metric)15 L/hr.
Length (English)10 in.
Length (Metric)26 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
Catalog Number
Unit Size
Each
Type
Electric
Output Flow Rate
2 gal./hr.
Electrical Requirements
240 V 50/60 Hz
Price (KRW)
Full specifications
Amperage26 A
Dimensions (L x W x H)11 x 23 x 68 in. (28 x 58 x 173 cm)
Electrical Requirements240 V 50/60 Hz
Frequency50/60 Hz
Phase1
Voltage240 V
Flow Rate2 gal./hr.
TypeElectric
Output Flow Rate2 gal./hr.
Model2 gal./hr. (240 V) Floor Electric with Stand
Height (English)68 in.
Height (Metric)173 cm
Width (English)23 in.
Width (Metric)58 cm
Cooling Flow Rate (English)16 gal./hr.
Cooling Flow Rate (Metric)61 L/hr.
Length (English)11 in.
Length (Metric)28 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
Catalog Number
Unit Size
Each
Type
Electric
Output Flow Rate
2 gal./hr.
Electrical Requirements
208 V 50/60 Hz
Price (KRW)
Full specifications
Amperage17 A
Dimensions (L x W x H)11 x 23 x 68 in. (28 x 58 x 173 cm)
Electrical Requirements208 V 50/60 Hz
Frequency50/60 Hz
Phase3
Voltage208 V
Flow Rate2 gal./hr.
TypeElectric
Output Flow Rate2 gal./hr.
Model2 gal./hr. (204 V) Floor Electric with Stand
Height (English)68 in.
Height (Metric)173 cm
Width (English)23 in.
Width (Metric)58 cm
Cooling Flow Rate (English)16 gal./hr.
Cooling Flow Rate (Metric)61 L/hr.
Length (English)11 in.
Length (Metric)28 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
Catalog Number
Unit Size
Each
Type
Electric
Output Flow Rate
5 gal./hr.
Electrical Requirements
208 V 50/60 Hz
Price (KRW)
Full specifications
Amperage36 A
Dimensions (L x W x H)14 x 35 x 77 in. (36 x 89 x 196 cm)
Electrical Requirements208 V 50/60 Hz
Frequency50/60 Hz
Phase3
Voltage208 V
Flow Rate5 gal./hr.
TypeElectric
Output Flow Rate5 gal./hr.
Model5 gal./hr. (208 V) Floor Electric with Stand
Height (English)77 in.
Height (Metric)196 cm
Width (English)35 in.
Width (Metric)89 cm
Cooling Flow Rate (English)40 gal./hr.
Cooling Flow Rate (Metric)151 L/hr.
Length (English)14 in.
Length (Metric)36 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
Showing 5 of 5
Catalog NumberSpecificationsUnit SizeTypeOutput Flow RateElectrical RequirementsPrice (KRW)
A1015-B-61Full specifications
EachElectric5 gal./hr.240 V 50/60 HzContact Us ›
Amperage57 A
Dimensions (L x W x H)14 x 35 x 77 in. (36 x 89 x 196 cm)
Electrical Requirements240 V 50/60 Hz
Frequency50/60 Hz
Phase1
Voltage240 V
Flow Rate5 gal./hr.
TypeElectric
Output Flow Rate5 gal./hr.
Model5 gal./hr. (240 V) Floor Electric with Stand
Height (English)77 in.
Height (Metric)196 cm
Width (English)35 in.
Width (Metric)89 cm
Cooling Flow Rate (Metric)151 L/hr.
Length (English)14 in.
Length (Metric)36 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
A1007Full specifications
EachElectric (Portable)0.5 gal./hr.120 V 50/60 HzContact Us ›
Amperage12 A
Dimensions (L x W x H)10 x 21 x 19 in. (26 x 52 x 49 cm)
Electrical Requirements120 V 50/60 Hz
Frequency50/60 Hz
Phase1
Voltage120 V
Flow Rate0.5 gal./hr.
TypeElectric (Portable)
Output Flow Rate0.5 gal./hr.
Model0.5 gal./hr. Portable
Height (English)19 in.
Height (Metric)49 cm
Width (English)21 in.
Width (Metric)52 cm
Cooling Flow Rate (English)4 gal./hr.
Cooling Flow Rate (Metric)15 L/hr.
Length (English)10 in.
Length (Metric)26 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
A1013-B-61Full specifications
EachElectric2 gal./hr.240 V 50/60 HzContact Us ›
Amperage26 A
Dimensions (L x W x H)11 x 23 x 68 in. (28 x 58 x 173 cm)
Electrical Requirements240 V 50/60 Hz
Frequency50/60 Hz
Phase1
Voltage240 V
Flow Rate2 gal./hr.
TypeElectric
Output Flow Rate2 gal./hr.
Model2 gal./hr. (240 V) Floor Electric with Stand
Height (English)68 in.
Height (Metric)173 cm
Width (English)23 in.
Width (Metric)58 cm
Cooling Flow Rate (English)16 gal./hr.
Cooling Flow Rate (Metric)61 L/hr.
Length (English)11 in.
Length (Metric)28 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
A1013-CFull specifications
EachElectric2 gal./hr.208 V 50/60 HzContact Us ›
Amperage17 A
Dimensions (L x W x H)11 x 23 x 68 in. (28 x 58 x 173 cm)
Electrical Requirements208 V 50/60 Hz
Frequency50/60 Hz
Phase3
Voltage208 V
Flow Rate2 gal./hr.
TypeElectric
Output Flow Rate2 gal./hr.
Model2 gal./hr. (204 V) Floor Electric with Stand
Height (English)68 in.
Height (Metric)173 cm
Width (English)23 in.
Width (Metric)58 cm
Cooling Flow Rate (English)16 gal./hr.
Cooling Flow Rate (Metric)61 L/hr.
Length (English)11 in.
Length (Metric)28 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
A1015-CFull specifications
EachElectric5 gal./hr.208 V 50/60 HzRequest A Quote
Amperage36 A
Dimensions (L x W x H)14 x 35 x 77 in. (36 x 89 x 196 cm)
Electrical Requirements208 V 50/60 Hz
Frequency50/60 Hz
Phase3
Voltage208 V
Flow Rate5 gal./hr.
TypeElectric
Output Flow Rate5 gal./hr.
Model5 gal./hr. (208 V) Floor Electric with Stand
Height (English)77 in.
Height (Metric)196 cm
Width (English)35 in.
Width (Metric)89 cm
Cooling Flow Rate (English)40 gal./hr.
Cooling Flow Rate (Metric)151 L/hr.
Length (English)14 in.
Length (Metric)36 cm
Certifications/ComplianceUL, cUL
Unit SizeEach
Showing 5 of 5
  • Double-walled boiler and preheating of feed water conserves electricity.
  • Vented condenser allows for stripping of gaseous impurities.
  • Unique de-concentrator removes scale forming impurities from the boiler.
  • Unique Q-Baffle ensures high-quality pyrogen-free water by stripping contaminant laden water droplets from steam.
  • Still includes space-saving horizontal condenser.
  • Metal construction withstands years of use.
  • Inert pure tin pathways assure product water quality.

Portable Stills:

  • Require no permanent plumbing or electrical connections allowing for quick setup
  • Include low water cutoff for safety protection
  • Bench mounted

Floor Model Electric Still:

  • Comes standard with floor mounting stand
  • Improves safety with new overtemperature protection system
  • Allows for easier installation with new plug-and-play hardware
  • Processes capacities from 1 to 10 gal./hr.
  • Includes low water cutoff that protects heating elements when water supply is interrupted
  • Allows for unattended operation with optional fully automatic controls
  • Stops still when storage tank is full, starts still when water level falls below preset level
  • Drains still boiler at selected two-, four-, eight- and 16-hour intervals to reduce scale formation

Steam Still:

  • Utilizes available in-house steam as heat source
  • Optional fully automatic controls allow for unattended operation
  • Stops still when storage tank is full, starts still when water level falls below preset level
  • Drains still boiler at selected two-, four-, eight- and 16-hour intervals to reduce scale formation
  • Steam pressure: 35 to 50psi
  • Boiler horsepower: 3.5
  • Steam flowrate: 90 lb./hr. (41kg/hr.)

Ordering Information:

Automated control systems are available for all stills: G2100 (for 1 gal./hr., 2 gal./hr. models), G2110 (5 gal./hr.), G2125 (10 gal./hr.) and G2010 (10 gal./hr.). Order separately.

This product is not available in all regions.

Includes:

Floor stand (exept for Portable Model A1007).

Requires:

Storage reservoir, UV light assembly and Ventgard Air Filter (order separately)

Recommended for:

Buffer/reagent prep, glassware washing, dishwasher feed

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text