| ISQ7610-NOVPI | 전체 사양 | Each | ISQ 7610 Large Turbo, No VPI with ExtractaBrite | Ultra-Inert ExtractaBrite Ion Source | 견적 요청하기 |
질량 범위 | 1.2–1100 u with Unit Mass Resolution | 유형 | Single Quadrupole GC-MS | 검출기 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | 모드 | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection | 스캔 기능 | Fast Quadrupole Scanning up to 20,000 U/s | 소스 유형 | Ultra-Inert ExtractaBrite Ion Source | 항목 설명 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | 설명 | ISQ 7610 Large Turbo, No VPI with ExtractaBrite | 질량 안정성 | Better than 0.1 u/48 hours/∆T ≤2 K | 치수 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods1.2–1100 u with Unit Mass Resolution | Unit Size | Each |
|
| ISQ7610-VPI | 전체 사양 | Each | ISQ 7610 Large Turbo VPI with ExtractaBrite | Ultra-Inert ExtractaBrite Ion Source | 견적 요청하기 |
질량 범위 | 1.2–1100 u with Unit Mass Resolution | 유형 | Single Quadrupole GC-MS | 검출기 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | 모드 | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection, Chemical Ionization (CI), with Positive Ion (PCI) and Negative Ion (NCI) Chemical Ionization, Interchangeable without breaking the vacuum | 스캔 기능 | Fast Quadrupole Scanning up to 20,000 U/s | 소스 유형 | Ultra-Inert ExtractaBrite Ion Source | 항목 설명 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | 설명 | ISQ 7610 Large Turbo VPI with ExtractaBrite | 질량 안정성 | Better than 0.1 u/48 hours/∆T ≤2 K | 치수 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|
| ISQ7610-VPICI | 전체 사양 | Each | ISQ 7610 Large Turbo, No VPI with AEI | Ultra-Inert ExtractaBrite Ion Source | 견적 요청하기 |
질량 범위 | 1.2–1100 u with Unit Mass Resolution | 유형 | Single Quadrupole GC-MS | 검출기 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | 모드 | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection, Chemical Ionization (CI), with Positive Ion (PCI) and Negative Ion (NCI) Chemical Ionization, Interchangeable without breaking the vacuum | 스캔 기능 | Fast Quadrupole Scanning up to 20,000 U/s | 소스 유형 | Ultra-Inert ExtractaBrite Ion Source | 항목 설명 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | 설명 | ISQ 7610 Large Turbo, No VPI with AEI | 질량 안정성 | Better than 0.1 u/48 hours/∆T ≤2 K | 치수 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|
| ISQ7610-STNOVPI | 전체 사양 | Each | ISQ 7610 Small Turbo, No VPI with ExtractaBrite | Ultra-Inert ExtractaBrite Ion Source | 견적 요청하기 |
질량 범위 | 1.2–1100 u with Unit Mass Resolution | 유형 | Single Quadrupole GC-MS | 검출기 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | 모드 | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection | 스캔 기능 | Fast Quadrupole Scanning up to 20,000 U/s | 소스 유형 | Ultra-Inert ExtractaBrite Ion Source | 항목 설명 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration + | 설명 | ISQ 7610 Small Turbo, No VPI with ExtractaBrite | 질량 안정성 | Better than 0.1 u/48 hours/∆T ≤2 K | 치수 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|
| ISQ7610-AEI | 전체 사양 | Each | ISQ 7610 Large Turbo, No VPI with AEI | Advanced Electron Ionization (AEI) Source for Ultra-Sensitivity and Robustness | 견적 요청하기 |
질량 범위 | 1.2–1100 u with unit mass resolution | 유형 | Single Quadrupole GC-MS | 검출기 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | 모드 | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection | 스캔 기능 | Fast Quadrupole Scanning up to 20,000 U/s | 소스 유형 | Advanced Electron Ionization (AEI) Source for Ultra-Sensitivity and Robustness | 항목 설명 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | 설명 | ISQ 7610 Large Turbo, No VPI with AEI | 질량 안정성 | Better than 0.1 u/48 hours/∆T ≤2 K | 치수 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|