Applied Biosystems™

SeqStudio™ 8 Flex Genetic Analyzer

製品番号(カタログ番号): A53628
Applied Biosystems™

SeqStudio™ 8 Flex Genetic Analyzer

製品番号(カタログ番号): A53628
The Applied Biosystems SeqStudio 8 Flex Genetic Analyzer offers design improvements and technological advances to the capillary electrophoresis (CE) workflow. It delivers gold-standard Sanger sequencing and fragment analysis data quality with increased flexibility, easier operation, and cloud connectivity to enable researchers to manage their workloads and work/life balance effectively. Designed for ultimate ease-of-use, this mid-throughput system offers high quality, excellent reliability, and an optimal user experience for researchers who want to work smarter in the lab.
 
製品番号(カタログ番号)
A53628
容量
Each
外部コンピューター
Desktop
仕様詳細
概要SeqStudio™ 8 Flex with Desktop Computer
容量4 Plates
Capillary Length36 or 50 cm
使用対象(アプリケーション)Sanger Sequencing, Fragment Analysis
使用対象 (装置)Thermal Cyclers
Number of Capillaries8 Capillaries
製品ラインSeqStudio Flex
Read Length≥850 bp (Using run module StdSeq50_POP7)
スループット≥368 samples in 23 hr. (Using run module ShortReadSeq50_POP7)
タイプGenetic Analyzer
外部コンピューターDesktop
フィルター済みFiltered
フォーマット96-well plates or 8-tube strips
高スループット適合性No
操作環境59°F to 86°F (15°C to 30°C), 20 to 80% relative humidity (non-condensing). Room temperature should not fluctuate ±2°C during an instrument run.
ポリマーPOP-4™, POP-6™, POP-7™
電力要件100/240 ± 10% VAC, 50/60 Hz
出荷条件-22°F to 140°F (-30°C to 60°C), 5 to 95% relative humidity
無菌性Non-sterile
温度範囲(摂氏)18°C to70°C (Oven temperature control)
寸法27.6 x 26.6 x 34.1 in. (70 x 67.5 x 86.5 cm)
重量253.5 lb. (115 kg)
電圧100/240 V
Total Service CoverageStandard 1-year warranty included; extended warranties available
最大電力Electrophoresis Voltage Up to 20 kV
Unit SizeEach
製品番号(カタログ番号)
容量
Each
外部コンピューター
Laptop
仕様詳細
概要SeqStudio™ 8 Flex with Laptop
容量4 Plates
Capillary Length36 or 50 cm
使用対象(アプリケーション)Sanger Sequencing, Fragment Analysis
使用対象 (装置)Thermal Cyclers
Number of Capillaries8 Capillaries
製品ラインSeqStudio Flex
Read Length≥850 bp (Using run module StdSeq50_POP7)
スループット≥368 samples in 23 hr. (Using run module ShortReadSeq50_POP7)
タイプGenetic Analyzer
外部コンピューターLaptop
フィルター済みFiltered
フォーマット96-well plates or 8-tube strips
高スループット適合性No
操作環境59°F to 86°F (15°C to 30°C), 20 to 80% relative humidity (non-condensing). Room temperature should not fluctuate ±2°C during an instrument run.
ポリマーPOP-4™, POP-6™, POP-7™
電力要件100/240 ± 10% VAC, 50/60 Hz
出荷条件-22°F to 140°F (-30°C to 60°C), 5 to 95% relative humidity
温度範囲(摂氏)18°C to70°C (Oven temperature control)
寸法27.6 x 26.6 x 34.1 in. (70 x 67.5 x 86.5 cm)
重量253.5 lb. (115 kg)
電圧100/240 V
Total Service CoverageStandard 1-year warranty included; extended warranties available
最大電力Electrophoresis Voltage Up to 20 kV
Unit SizeEach
製品番号(カタログ番号)
容量
Each
外部コンピューター
Not Included
仕様詳細
概要SeqStudio™ 8 Flex
Capillary Length36 or 50 cm
使用対象 (装置)Thermal Cyclers
外部コンピューターNot Included
フィルター済みFiltered
フォーマット96-well plates or 8-tube strips
高スループット適合性No
操作環境59–86°F (15–30°C), 20–80% relative humidity (non-condensing). Room temperature should not fluctuate ±2°C during an instrument run.
ポリマーPOP-4™, POP-6™, POP-7™
電力要件100–240 ± 10% VAC; 50/60 Hz
出荷条件–22° to 140°F (–30° to 60°C), 5–95% relative humidity
無菌性Non-sterile
温度範囲(摂氏)18–70°C (Oven temperature control)
寸法27.6 x 26.6 x 34.1 in. (70 x 67.5 x 86.5 cm)
重量253.5 lb. (115 kg)
電圧100/240 V
Total Service CoverageStandard 1-year warranty included, extended warranties available
最大電力Electrophoresis Voltage Up to 20 kV
Unit SizeEach
3 / 3 を表示
製品番号(カタログ番号)仕様容量外部コンピューター価格(JPY)
A53628仕様詳細
EachDesktop見積もりを依頼する
概要SeqStudio™ 8 Flex with Desktop Computer
容量4 Plates
Capillary Length36 or 50 cm
使用対象(アプリケーション)Sanger Sequencing, Fragment Analysis
使用対象 (装置)Thermal Cyclers
Number of Capillaries8 Capillaries
製品ラインSeqStudio Flex
Read Length≥850 bp (Using run module StdSeq50_POP7)
スループット≥368 samples in 23 hr. (Using run module ShortReadSeq50_POP7)
タイプGenetic Analyzer
外部コンピューターDesktop
フィルター済みFiltered
フォーマット96-well plates or 8-tube strips
高スループット適合性No
操作環境59°F to 86°F (15°C to 30°C), 20 to 80% relative humidity (non-condensing). Room temperature should not fluctuate ±2°C during an instrument run.
ポリマーPOP-4™, POP-6™, POP-7™
電力要件100/240 ± 10% VAC, 50/60 Hz
出荷条件-22°F to 140°F (-30°C to 60°C), 5 to 95% relative humidity
無菌性Non-sterile
温度範囲(摂氏)18°C to70°C (Oven temperature control)
寸法27.6 x 26.6 x 34.1 in. (70 x 67.5 x 86.5 cm)
重量253.5 lb. (115 kg)
電圧100/240 V
Total Service CoverageStandard 1-year warranty included; extended warranties available
最大電力Electrophoresis Voltage Up to 20 kV
Unit SizeEach
A53629仕様詳細
EachLaptop見積もりを依頼する
概要SeqStudio™ 8 Flex with Laptop
容量4 Plates
Capillary Length36 or 50 cm
使用対象(アプリケーション)Sanger Sequencing, Fragment Analysis
使用対象 (装置)Thermal Cyclers
Number of Capillaries8 Capillaries
製品ラインSeqStudio Flex
Read Length≥850 bp (Using run module StdSeq50_POP7)
スループット≥368 samples in 23 hr. (Using run module ShortReadSeq50_POP7)
タイプGenetic Analyzer
外部コンピューターLaptop
フィルター済みFiltered
フォーマット96-well plates or 8-tube strips
高スループット適合性No
操作環境59°F to 86°F (15°C to 30°C), 20 to 80% relative humidity (non-condensing). Room temperature should not fluctuate ±2°C during an instrument run.
ポリマーPOP-4™, POP-6™, POP-7™
電力要件100/240 ± 10% VAC, 50/60 Hz
出荷条件-22°F to 140°F (-30°C to 60°C), 5 to 95% relative humidity
温度範囲(摂氏)18°C to70°C (Oven temperature control)
寸法27.6 x 26.6 x 34.1 in. (70 x 67.5 x 86.5 cm)
重量253.5 lb. (115 kg)
電圧100/240 V
Total Service CoverageStandard 1-year warranty included; extended warranties available
最大電力Electrophoresis Voltage Up to 20 kV
Unit SizeEach
A53627仕様詳細
Each Not Included見積もりを依頼する
概要SeqStudio™ 8 Flex
Capillary Length36 or 50 cm
使用対象 (装置)Thermal Cyclers
外部コンピューターNot Included
フィルター済みFiltered
フォーマット96-well plates or 8-tube strips
高スループット適合性No
操作環境59–86°F (15–30°C), 20–80% relative humidity (non-condensing). Room temperature should not fluctuate ±2°C during an instrument run.
ポリマーPOP-4™, POP-6™, POP-7™
電力要件100–240 ± 10% VAC; 50/60 Hz
出荷条件–22° to 140°F (–30° to 60°C), 5–95% relative humidity
無菌性Non-sterile
温度範囲(摂氏)18–70°C (Oven temperature control)
寸法27.6 x 26.6 x 34.1 in. (70 x 67.5 x 86.5 cm)
重量253.5 lb. (115 kg)
電圧100/240 V
Total Service CoverageStandard 1-year warranty included, extended warranties available
最大電力Electrophoresis Voltage Up to 20 kV
Unit SizeEach
3 / 3 を表示

Features of the SeqStudio 8 Flex Genetic Analyzer include:
• Space savings with true standalone operation; setup, start, monitor, and analyze directly on the touchscreen
• Improve workload management with continuous plate loading and sample reprioritization
• Realize lab efficiencies with remote monitoring
• New, improved capillary arrays for simple and hassle-free handling
• Reduce downtime with integrated remote troubleshooting tools

Easy-to-use data collection software
The data collection software pre-installed on the on-board touch screen computer takes user-friendliness to a new level. It offers an intuitive dashboard design, simplified plate set-up, and embedded self-help videos for common operations so that new users can get up and running quickly.

Scheduling flexibility
Four-plate capacity, continuous plate loading, and urgent sample reprioritization provide both the largest mid-throughput capacity and complete scheduling flexibility, translating into extra time in your day.

Remote functionality
Our cloud-based Connect platform provides enhanced flexibility by allowing users to set up plate files, monitor instrument and consumables performance and run progress, and even perform some critical instrument functions from anywhere.

Stay connected to your data
The SeqStudio 8 Flex system offers an automated workflow to obtain and share results from existing secondary analysis applications on Connect. These web-based software applications include Peak Scanner, Microsatellite Analysis, NGS Confirmation, Quality Check and Variant Analysis. They are compatible with Mac and PC.

Peace of mind with Smart service
Minimize downtime with premium service offerings for the SeqStudio 8 Flex Genetic Analyzer. Smart Help allows users to contact technical support directly from the touchscreen, without the need to download files or spend time on the phone. Experienced technicians will analyze the request and respond according to the user’s preference (phone or email) and resolve the issue as quickly as possible.

Smart Remote Support is an immersive collaboration tool that allows customers to show issues quickly and efficiently to technical support for resolution, helping reduce instrument downtime and minimize the need for on-site visits.

High application versatility
Simple workflows, reliable assays and reagents, and intuitive software are available for a broad range of applications, including multiplexed PCR analysis, next-generation confirmation, species identification, STR genotyping, cell-line authentication, dsDNA quality control, plasmid sequencing, and genome editing analysis.

Upgrade capabilities when you need them
The SeqStudio 8 Flex Genetic Analyzer can be seamlessly upgraded to a SeqStudio 24 Flex Genetic Analyzer by a field service engineer to provide additional throughput as your workload increases.

Results you can trust
Well-to-well and instrument-to-instrument data accuracy is achieved with the proven Applied Biosystems capillary electrophoresis technology.

For Research Use Only.

ドキュメントおよびダウンロード

証明書

    よくあるご質問(FAQ)

    引用および参考文献

    Search citations by name, author, journal title or abstract text