Thermo Scientific™

AutoFLEX Flow Computer

製品番号(カタログ番号): AUTOFLEX
Thermo Scientific™

AutoFLEX Flow Computer

製品番号(カタログ番号): AUTOFLEX
The Thermo Scientific™ AutoFLEX offers a flexible platform allowing operators from wellhead to consumer increase their ability to monitor instrument performance, flow throughput, and other metrics via increased processing power. This helps users to to avoid costly unplanned downtime, make better maintenance decisions based on collected data, and potentially save tens of millions of dollars per year on lost productivity and repairs.
 
製品番号(カタログ番号)
AUTOFLEX
または、製品番号AUTOFLEXFLOWCOMPUTER
容量
Each
仕様詳細
エンクロージャー定格IP65 (NEMA 4X)
入力電源10 VDC to 30 VDC
生密度入力UGC, 4 to 20 mA
プログラムメモリ256 MB
監査証跡User configurable; defaulting to 200 audit events, 60 different types of audits
認証/コンプライアンスCSA/C-US Class I, Div 2, Groups C and D hazardous locations; ambient temperature range of -40°C to +85°C, temperature code T3Cl Type 4X enclosure)
通信ポート(2) Serial (2) Ethernet (1) USB
奥行き(ヤードポンド法)6.9 in.
奥行き(メートル法)カバー175.26 mm
高さ(ヤードポンド法)7.5 in.
高さ(メートル法)190.5 mm
動作湿度範囲0 to 95% RH, Non-condensing
幅(ヤードポンド法)7.18 in.
幅(メートル法)182.37 mm
Unit SizeEach
1 / 1 を表示
製品番号(カタログ番号)仕様容量価格(JPY)
AUTOFLEX
または、製品番号AUTOFLEXFLOWCOMPUTER
仕様詳細
Each見積もりを依頼する
エンクロージャー定格IP65 (NEMA 4X)
入力電源10 VDC to 30 VDC
生密度入力UGC, 4 to 20 mA
プログラムメモリ256 MB
監査証跡User configurable; defaulting to 200 audit events, 60 different types of audits
認証/コンプライアンスCSA/C-US Class I, Div 2, Groups C and D hazardous locations; ambient temperature range of -40°C to +85°C, temperature code T3Cl Type 4X enclosure)
通信ポート(2) Serial (2) Ethernet (1) USB
奥行き(ヤードポンド法)6.9 in.
奥行き(メートル法)カバー175.26 mm
高さ(ヤードポンド法)7.5 in.
高さ(メートル法)190.5 mm
動作湿度範囲0 to 95% RH, Non-condensing
幅(ヤードポンド法)7.18 in.
幅(メートル法)182.37 mm
Unit SizeEach
1 / 1 を表示
Features include:
  • Optimal scalability
  • Enhanced security
  • CO2 measurement calculations
Scalable All-in-One Platform: From simple wellhead measurement to natural gas storage facility, the Thermo Scientific™ AutoFLEX flow computer coupled with the AutoCONFIG interface facilitates measurement, control, and monitoring of all critical points within a measurement system.
Maximum cybersecurity protection: Avoid unwanted intrusion with enhanced security including compliance to California SB-327, obscure Password, and Password Table Encryption. Remote monitoring of Usernames and Passwords also now available.
Full Suite of Gas and Liquid Calculations: AutoCONFIG contains a full suite of gas and liquid calculations all complying to the latest API 21.1 and 21.2 standards. Ability to measure Supercritical fluids such as CO2 and Ethylene via various measurement technologies is also included in this suite of calculations.

ドキュメントおよびダウンロード

証明書

    よくあるご質問(FAQ)

    引用および参考文献