| ISQ7610-NOVPI | 仕様詳細 | Each | ISQ 7610 Large Turbo, No VPI with ExtractaBrite | Ultra-Inert ExtractaBrite Ion Source | 見積もりを依頼する |
質量範囲 | 1.2–1100 u with Unit Mass Resolution | タイプ | Single Quadrupole GC-MS | 検出器 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | モード | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection | 読取り性能 | Fast Quadrupole Scanning up to 20,000 U/s | 光源タイプ | Ultra-Inert ExtractaBrite Ion Source | 品目詳細 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | 概要 | ISQ 7610 Large Turbo, No VPI with ExtractaBrite | 質量安定性 | Better than 0.1 u/48 hours/∆T ≤2 K | 寸法 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods1.2–1100 u with Unit Mass Resolution | Unit Size | Each |
|
| ISQ7610-VPI | 仕様詳細 | Each | ISQ 7610 Large Turbo VPI with ExtractaBrite | Ultra-Inert ExtractaBrite Ion Source | 見積もりを依頼する |
質量範囲 | 1.2–1100 u with Unit Mass Resolution | タイプ | Single Quadrupole GC-MS | 検出器 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | モード | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection, Chemical Ionization (CI), with Positive Ion (PCI) and Negative Ion (NCI) Chemical Ionization, Interchangeable without breaking the vacuum | 読取り性能 | Fast Quadrupole Scanning up to 20,000 U/s | 光源タイプ | Ultra-Inert ExtractaBrite Ion Source | 品目詳細 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | 概要 | ISQ 7610 Large Turbo VPI with ExtractaBrite | 質量安定性 | Better than 0.1 u/48 hours/∆T ≤2 K | 寸法 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|
| ISQ7610-VPICI | 仕様詳細 | Each | ISQ 7610 Large Turbo, No VPI with AEI | Ultra-Inert ExtractaBrite Ion Source | 見積もりを依頼する |
質量範囲 | 1.2–1100 u with Unit Mass Resolution | タイプ | Single Quadrupole GC-MS | 検出器 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | モード | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection, Chemical Ionization (CI), with Positive Ion (PCI) and Negative Ion (NCI) Chemical Ionization, Interchangeable without breaking the vacuum | 読取り性能 | Fast Quadrupole Scanning up to 20,000 U/s | 光源タイプ | Ultra-Inert ExtractaBrite Ion Source | 品目詳細 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | 概要 | ISQ 7610 Large Turbo, No VPI with AEI | 質量安定性 | Better than 0.1 u/48 hours/∆T ≤2 K | 寸法 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|
| ISQ7610-STNOVPI | 仕様詳細 | Each | ISQ 7610 Small Turbo, No VPI with ExtractaBrite | Ultra-Inert ExtractaBrite Ion Source | 見積もりを依頼する |
質量範囲 | 1.2–1100 u with Unit Mass Resolution | タイプ | Single Quadrupole GC-MS | 検出器 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | モード | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection | 読取り性能 | Fast Quadrupole Scanning up to 20,000 U/s | 光源タイプ | Ultra-Inert ExtractaBrite Ion Source | 品目詳細 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration + | 概要 | ISQ 7610 Small Turbo, No VPI with ExtractaBrite | 質量安定性 | Better than 0.1 u/48 hours/∆T ≤2 K | 寸法 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|
| ISQ7610-AEI | 仕様詳細 | Each | ISQ 7610 Large Turbo, No VPI with AEI | Advanced Electron Ionization (AEI) Source for Ultra-Sensitivity and Robustness | 見積もりを依頼する |
質量範囲 | 1.2–1100 u with unit mass resolution | タイプ | Single Quadrupole GC-MS | 検出器 | Triple off-axis Thermo Scientific™ DynaMax™ XTEND XR detection system, with off-axis 10 kV dynode, discrete dynode electron multiplier and electrometer, linear from 0 to 110 μA | モード | Electron Impact Ionization (EI), with Full Scan (FS), SIM, and FS/SIM, Simultaneous within the same injection | 読取り性能 | Fast Quadrupole Scanning up to 20,000 U/s | 光源タイプ | Advanced Electron Ionization (AEI) Source for Ultra-Sensitivity and Robustness | 品目詳細 | Scalable GC-MS platform, fully upgradable from a base configuration to an advanced highly sensitive configuration | 概要 | ISQ 7610 Large Turbo, No VPI with AEI | 質量安定性 | Better than 0.1 u/48 hours/∆T ≤2 K | 寸法 | 46 x 36 x 69 cm (18 x 14 x 27 in) (H x W x D) | Mass Analyzer | Dual-stage mass filter with off-axis ion guide pre-filter for noise reduction and solid, homogeneous non- coated, maintenance-free quadrupole rods | Unit Size | Each |
|