All Invitrogen precast protein gels are high-quality polyacrylamide gels designed to deliver excellent performance, reliability, and reproducibility. Our protein gels are offered in four different chemistries. Whether your protein is 2.5 kDa or as large as 500 kDa, or you’re looking for separation under native conditions or by isoelectric point—we have a solution for your application.

Video Player is loading.
Current Time 0:00
Duration 0:00
Loaded: 0%
Stream Type LIVE
Remaining Time 0:00
 
1x
    • Chapters
    • descriptions off, selected
    • captions off, selected
      Learn about WedgeWell protein gels

      Four gel chemistries for tailored SDS-PAGE separation

      Exceptional protein gel electrophoresis is the cornerstone of a successful western blotting experiment. Invitrogen precast protein gels are offered in four different chemistries, allowing you to tailor the separation to your target protein's molecular weight. This helps obtain sharp, well-resolved bands, and results in efficient transfer and improved detection of your protein.

       Bis-Tris Gels
      Bis-Tris Gels
      Tris-Glycine Gels
      Tris-Glycine Gels
      Tris-Acetate Gels
      Tris-Acetate Gels
      Tricine Gels
      Tricine Gels
      Available precast gelsNuPAGE Bis-Tris Gels, Bolt Bis-Tris Plus GelsNovex Tris-GlycineNuPAGE Tris-AcetateNovex Tricine
      Use for

      Neutral pH environment helps prevent protein degradation

      Faster run times

      Dilute samples, low abundance proteins

      Traditional Laemmli-style gel electrophoresisImproved resolution of high molecular weight proteinsImproved resolution of low molecular weight proteins
      Protein sample typeBroad range MW (6–400 kDa)Broad range MW (6–400 kDa)High range MW (40–500 kDa)Low range MW (2.5–40 kDa)
      WedgeWell format gelsMidi and mini (load up to 100 and 60 µL, respectively)Midi and mini (load up to 100 and 60 µL, respectively)Midi and mini (load up to 100 and 60 µL, respectively)

      -

      Average run time22–45 min Bolt gels 35–50 min NuPAGE90 min60 min90 min
      Shelf life*Up to 16 months at room temperatureUp to 12 monthsUp to 8 months1–2 months

      Get started with our money-saving Protein Gel Welcome Packs

      Restock with Protein Gel Resupply Packs


      High loading capacity meets high sample throughput

      WedgeWell format wells are wedge-shaped wells that increase the sample loading capacity, allowing up to 100 µL of sample to be loaded in the well. The WedgeWell design was introduced in 2012 to increase the sample loading capacity of Invitrogen precast mini gels.

      Figure 1.Comparison of a Mini WedgeWell well and traditional Mini gel well shape.
       

      More than a thousand peer-reviewed articles demonstrate how WedgeWell format gels help produce publication-quality results and enable the study of low abundance proteins, reducing the need to enrich dilute samples before loading them onto the gel.

      “WedgeWell gels hold up to 60 μL of sample/well making it feasible to load enough protein for dilute OMV suspensions.” [1]

      “The large wedgewells are excellent for loading large volumes.” [2]

      Midi gels with WedgeWell format wells allow the separation of up to 26 protein samples in the same run without compromising on sample loading volume.

      Key benefits of WedgeWell format gels:

      • Results you can trust—rigorously tested to help ensure reliable, reproducible performance, lot after lot
      • Easy sample loading—larger well openings make loading a breeze even with standard pipette tips, and reduce sample spill-over and cross well contamination
      • Increased sample loading capacity—easy detection of dilute samples and low abundance proteins
      • Reduced cost—lower cost per sample and reduced running buffer required per sample (7.3 mL of running buffer saved per sample, 140 mL saved for 20 samples)*
      • Faster run times—up to 10 min faster than traditional gels

      Available in three different gel chemistries:

      All Invitrogen protein gels meet the highest standards of performance, reliability, and consistency.

      See our Protein Gel Performance Guarantee

      *Based on comparison between our most popular mini and midi well format options (12 and 20 well, respectively)


      Recommended sample loading volumes for mini and midi gels

      Well sizeMaximum loading volume (µL)
        WedgeWell format midi gelsStandard midi gels
      12 + 2 (small wells) 100 + 35 50 + 15
      20 60 30
      26 40 20
        WedgeWell format mini gelsStandard mini gels
      10 60 25
      12 45 20
      15 35 15
      17 30 15
      *1 mm thick gel
       

      IEF and specialized gels

      For separation of proteins under nondenaturing conditions or native page, three gel systems are recommended- NativePAGE Bis-Tris, Novex Tris-Glycine and NuPAGE Tris-Acetate. NativePAGE Bis-Tris gels, are based on the blue native polyacrylamide gel electrophoresis (BN-PAGE) which helps overcome the limitations of traditional native electrophoresis by providing a near-neutral operating pH and detergent compatibility. Both Novex Tris-Glycine and NuPAGE Tris-Acetate gels can be run under native and non-reducing conditions for separation of proteins by net charge, size and shape.

      For separation of proteins by isoelectroctric point (pI), use Novex IEF gels. Novex IEF gels effectively create a pH gradient to separate proteins according to their unique pI.

       NativePAGE Bis-Tris Gels
      NativePAGE Bis-Tris Gels
      Isoelectric Focusing Gels
      Isoelectric Focusing Gels
      Novex Zymogram Gels
      Novex Zymogram Gels
      E-PAGE Precast Gels
      E-PAGE Precast
      Gels

      Gel chemistryBis-TrispH 3–7, pH 3–10Tris-glycine with gelatin8% or 6%
      Protein sample type15–10,000 kDapI 3.5–8.510–220 kDa10–200 kDa
      Product benefitsSeparation of native proteins, neutral pH for high sensitivity applicationsSeparation of proteins based on isoelectric pointSeparation of proteins based on size and activityHigh-throughput gel system, that eliminates the need for buffers

      Handcast System

       SureCast Handcast System
      SureCast Handcast System
      Empty Gel Cassettes
      Empty Gel Cassettes
      Bolt Empty Cassettes
      Bolt Empty Cassettes
      Cassette typeReusable, glassSingle use, pre-sealedSingle use, pre-sealed
      Product benefits
      • Leak-free design—minimize the number of failed gels, waste less time
      • Superior glass plate durability
      • Unique tilt feature—helps minimize spillage and confidently load acrylamide solutions
      • Simple component assembly—using a single-motion load-and-lock mechanism
      • Ready-to-pour cassettes, casting stand not required, cassettes sealed on three sides (no gel leakage)
      • Special coating provides uniform polymerization rate for a more consistent handcast gel
      • High capacity sample wells—load up to 60 µL per well
      • Ready-to-pour cassettes, casting stand not required, cassettes sealed on three sides (no gel leakage)
      • Special coating provides uniform polymerization rate for a more consistent handcast gel
      Gel dimensionsMini: 8x8 cm (1 mm thick)Mini: 8x8 cm (1 or 1.5 mm thick) Midi: 8x13 cm (1 mm thick)Mini: 8x8 cm (1 mm thick)
      Gel tankMini Gel Tank, Xcell SureLock Mini-CellMini Gels: Mini Gel Tank or XCell SureLock Mini-Cell Midi Gels: XCell4 SureLock Midi-Cell or Bio-Rad Criterion (with adapters only)Mini Gel Tank, Xcell SureLock Mini-Cell
      ReagentsSureCast reagents, other popular polyacrylamide reagentsSureCast reagents, other popular polyacrylamide reagentsSureCast reagents, other popular polyacrylamide reagents
      Combos available1-, 2-, 10-, 12-, and 15-wells1-, 2-, 5-, 10-, 12-, 15-, and 2D-wells10- or 12-wells (high capacity wells)

      How-to videos

      Video Player is loading.
      Current Time 0:00
      Duration 0:00
      Loaded: 0%
      Stream Type LIVE
      Remaining Time 0:00
       
      1x
        • Chapters
        • descriptions off, selected
        • captions off, selected

          How to choose the right protein gel for your research application

          This webinar will highlight the different protein modifications occurring during electrophoresis, the importance of pH in sample integrity, how to choose the right gel chemistry for specific research applications, and how to introduce the right gel chemistry in your research workflow.

          Video Player is loading.
          Current Time 0:00
          Duration 0:00
          Loaded: 0%
          Stream Type LIVE
          Remaining Time 0:00
           
          1x
            • Chapters
            • descriptions off, selected
            • captions off, selected

              How to separate proteins using an Invitrogen precast SDS-PAGE gel

              This video will show you how to separate proteins by using Invitrogen Mini Gel Tank and Invitrogen precast SDS-PAGE gels.


              Protein Gel Selection Guide

              Protein Gel Selection Guide

              Find an excellent mini or midi gel for your protein electrophoresis experiment.

              Gel Selection Chart

              Protein Gel Conversion Tool

              Find an exceptional Invitrogen mini or midi gel to replace your current precast gel from another supplier.

              Protein Gel Options Brochure

              Gel Migration Chart

              Download the Protein Gel Guide for a printable gel migration chart.

              Still unsure which precast gel works best for your research needs? Download the Gel Selection Chart


              Protein Gels Performance Guarantee

              Protein Gels Performance Guarantee

              We stand behind the performance of our protein gels.

              Learn more

              References

              1. Libardo, M.D.J.; Durr, E.; Hernandez, L.D. A Robust Protocol to Isolate Outer Membrane Vesicles from Nontypeable Haemophilus influenzae.Methods Protoc.2023,6, 42. https://doi.org/10.3390/mps6020042
              2. Horita, H., Law, A., Middleton, K. Utilizing a Comprehensive Immunoprecipitation Enrichment System to Identify an Endogenous Post-translational Modification Profile for Target Proteins. J. Vis. Exp. (131), e56912, doi:10.3791/56912 (2018).
              Stylesheet for Classic Wide Template adjustments
              Hero banner dark gradient overlay

              For Research Use Only. Not for use in diagnostic procedures.