Overview

(U)HPLC columns optimized for your analytical performance

Solve your separation challenges with our HPLC and UHPLC columns for small molecules. Our popular product lines of Hypersil GOLD and Accucore columns are designed for a wide range of applications and offer the following features:

  • High-resolution HPLC and UHPLC columns
  • Built on a 40-year legacy of innovation
  • Unmatched variety of stationary phase chemistries, particle sizes, and column formats
  • Long column lifetime with reproducible results
  • The broadest assortment of solid core columns on the market

From the most commonly-used C18 phases, to innovative chemistries, we have the right column to fulfill your chromatography needs

Meet our (U)HPLC column families

Hypersil GOLD columns

Fully porous for simple samples

  • checkmarkFully porous, ultrapure silica particle columns
  • checkmarkBuilt on 40 years of experience in column development and manufacturing
  • checkmarkExcellent peak symmetry and lot-to-lot reproducibility
  • checkmarkWide variety of column sizes

Your first choice of columns for method development

  • Built on 40 years of experience in column development and manufacturing
  • Offered in a complete range of particle sizes, from HPLC to UHPLC, and a wide range of formats, from micro-flow, to analytical, to semi-preparative
  • Able to produce outstanding peak shape, resolution, and lot-to-lot consistency
  • Available with several reversed-phase, HILIC, and ion-exchange phases
 Hypersil GOLD Overview

Explore our complete range of Hypersil GOLD columns to start your chromatography analyses

Hydrophobic Column Phases

Reversed phase chemistry for separation via hydrophobic interactions. Stationary phases with longer carbon chains provide longer retention times and greater hydrophobicity.


C18, C8, C4

Polar-Modified C18 Column Phases

Good for the separation of acidic and basic compounds via reversed phase chromatography using an aqueous mobile phase.


aQ

Phenyl-Based Column Phases

Orthogonal selectivity to traditional hydrophobic phases that utilizes aromatic interactions to achieve challenging separations of aromatic and polar compounds.

Phenyl, PFP

Ion-Exchange Column Phases

Ionic and polar compounds are retained via hydrophilic and ionic interactions with a charged stationary phase. Retained compounds can be eluted by changing the solvent conditions of the column.


Amino, Cyano

Hydrophilic Columns

Ideal for retaining and separating polar compounds based on polarity differences and affinity for a polar stationary phase.

HILIC, Silica

Phase Name

1.9 µm

3 µm

5 µm

Pore Size (Å)

Carbon Load (%)

Surface Area (m²/g)

USP

Hypersil GOLD C18

Checkmark icon

Checkmark icon

Checkmark icon

175

10

220

L1

Hypersil GOLD C8

Checkmark icon

Checkmark icon

Checkmark icon

175

8

220

L7

Hypersil GOLD C4

Checkmark icon

Checkmark icon

Checkmark icon

175

5

220

L26

Hypersil GOLD aQ

Checkmark icon

Checkmark icon

Checkmark icon

175

12

220

L1

Hypersil GOLD PFP

Checkmark icon

Checkmark icon

Checkmark icon

175

8

220

L43

Hypersil GOLD Phenyl

Checkmark icon

Checkmark icon

Checkmark icon

175

8

220

L11

Hypersil GOLD Amino

Checkmark icon

Checkmark icon

Checkmark icon

175

2

220

L9

Hypersil GOLD Cyano

Checkmark icon

Checkmark icon

Checkmark icon

175

4

220

L10

Hypersil GOLD HILIC

Checkmark icon

Checkmark icon

Checkmark icon

175

6

220

Hypersil GOLD Silica

Checkmark icon

Checkmark icon

Checkmark icon

175

220

L3

Learn more about Hypersil GOLD columns

Solid core silica particles for high-resolution separation at any pressure

  •  Rugged, superficially porous particles
  •  Wide selection of chemistries
  •  Compatible with any HPLC or UHPLC system
Accucore HPLC and UHPLC columns

Discover high-throughput columns for rapid (U)HPLC separations

Hydrophobic Column Phases

Reversed phase chemistry for separation via hydrophobic interactions. Stationary phases with longer carbon chains provide longer retention times and greater hydrophobicity.

C18, C8, C4

Specialty Hydrophobic Column PhasesAlternative selectivity to C18 for hydrophobic retention and the geometric separation of structural isomers.

RP-MS, C30
Phenyl-Based Column Phases

Orthogonal selectivity to traditional hydrophobic phases that utilizes aromatic interactions to achieve challenging separations of aromatic and polar compounds.

Biphenyl, Phenyl-Hexyl, PFP

Polar-Modified C18 Column Phases

Good for the separation of acidic and basic compounds via reversed phase chromatography using an aqueous mobile phase

Polar Premium, aQ

HILIC Column Phases

Ideal for retaining and separating polar compounds based on polarity differences and affinity for a polar stationary phase.

HILIC, Amide HILIC

Phase Name

1.5 μm

2.6 μm

4 μm

Pore Size (Å)

Surface Area (m²/g)

Carbon Load (%)

USP

Accucore C18

Checkmark icon

80

130

9

L1

Accucore Vanquish C18+

Checkmark icon

80

130

6.5

L1

Accucore XL C18

Checkmark icon

80

130

7

L1

Accucore C8

Checkmark icon

80

130

9

L7

Accucore XL C8

Checkmark icon

80

130

4

L7

Accucore 150-C4

Checkmark icon

150

80

2

L26

Accucore aQ

Checkmark icon

80

130

9

L1

Accucore Polar Premium

Checkmark icon

80

130

8

L60

Accucore RP-MS

Checkmark icon

80

130

7

L1

Accucore C30

Checkmark icon

80

130

5

L62

Accucore Biphenyl

Checkmark icon

80

130

6

L11

Accucore Phenyl-Hexyl

Checkmark icon

80

130

5

L11

Accucore PFP

Checkmark icon

80

130

5

L43

Accucore Phenyl-X

Checkmark icon

80

130

6

Accucore HILIC

Checkmark icon

80

130

L3

Accucore 150-Amide-HILIC

Checkmark icon

150

80

Accucore Urea HILIC

Checkmark icon

80

130

Learn more about Accucore columns

HPLC column selection guide

3 ways to search

  1. Find an equivalent column to the one you’re using now
  1. Find the best column for your USP method
  1. Find the right column for your new method

Find your HPLC column with ease ›

 

Know your options

A great resource for getting familiar with and comparing (U)HPLC columns, our Premier Columns Guide contains:

  • Overview of column chemistries
  • Column comparison chart
  • Solid core versus fully porous supports
  • Pore size versus surface area
  • Quick guide to choosing a stationary phase
  • Ordering information

Download premier columns guide

 

* Required field

*
*
*
*
*
*
*
*
*
 Please confirm you would like to receive marketing and promotional email messages about Thermo Fisher Scientific products and services.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

 
 
CMD Form Code v3.0
Style Sheet for Global Design System
CMD Wide-format style fixes
Style Sheet for Global Design System
Style Sheet for Komodo Tabs
CMD SchemaApp code