Nunc™ Lab-Tek™ Chamber Slide System
Nunc™ Lab-Tek™ Chamber Slide System
Thermo Scientific™

Nunc™ Lab-Tek™ Chamber Slide System

Züchten Sie ädhärente Zellen sofort auf dem Mikroskopobjektträger mit der einzigartigen abnehmbaren Kammer des Thermo Scientific™ Nunc™ Lab-Tek™ Chamber Slide Systems.
Promo ImageSonderaktionen
Werbeaktionscode:RCELL51
Stock your lab with plasticware essentials so that you can culture with confidence
From now until Dec 31, get 51% off various cell culture plasticware like dishes, flasks, plates and tubes that help achieve reproducible resultsWeitere Informationen
Have Questions?
Ansicht ändernbuttonViewtableView
KatalognummerWellsMaterialPackungsgröße
177429PKPromo Image
auch als 177429 bezeichnet
2Permanox-KunststoffPack of 16
177372Promo Image1KalknatronglasCase of 96
177372PKPromo Image1KalknatronglasPack of 16
177380Promo Image2KalknatronglasCase of 96
177380PKPromo Image2KalknatronglasPack of 16
177399Promo Image4KalknatronglasCase of 96
177399PKPromo Image4KalknatronglasPack of 16
177402Promo Image8KalknatronglasCase of 96
177402PKPromo Image8KalknatronglasPack of 16
177410Promo Image1Permanox-KunststoffCase of 96
177410PKPromo Image
auch als 177410 bezeichnet
1Permanox-KunststoffPack of 16
177429Promo Image2Permanox-KunststoffCase of 96
177437Promo Image4Permanox-KunststoffCase of 96
177437PKPromo Image4Permanox-KunststoffPack of 16
177445Promo Image8Permanox-KunststoffCase of 96
177445PKPromo Image8Permanox-KunststoffPack of 16
178599Promo Image16KalknatronglasCase of 96
178599PKPromo Image16KalknatronglasPack of 16
Katalognummer 177429PK
auch als 177429 bezeichnet
Preis (EUR)
220,00
Pack of 16
Vorrätig
Zum Warenkorb hinzufügen
Wells:
2
Material:
Permanox-Kunststoff
Unit Size:
Pack of 16
Preis (EUR)
220,00
Pack of 16
Zum Warenkorb hinzufügen
Ask our AI about this Product

Kultivieren, färben und untersuchen Sie Zellen direkt auf dem Thermo Scientific™ Nunc™ Lab-Tek™ Chamber Slide™, der aus einer Polystyrol-Medienkammer besteht, die an einem Mikroskopobjektträger befestigt ist. Die Oberfläche des Objektträgers ist speziell für die Kultur adhärenter Zellen behandelt. Wählen Sie entweder Objektträger aus speziell gewaschenem Kalknatronglas oder die für die Zellanlagerung optimierten Objektträger aus Permanox-Kunststoff. Die Medienkammer lässt sich ohne Hilfsmittel mühelos entfernen.

Merkmale:
  • Die lösungsmittelbeständigen Permanox™ Kammerobjektträger aus Kunststoff sind in 1-, 2-, 4- und 8-Well-Formaten erhältlich.
  • Die speziell gewaschenen Kammerobjektträger aus Kalk-Natron-Glas sind in 1-, 2-, 4-, 8- und 16-Well-Formaten erhältlich.
  • Die Medienkammern lassen sich ohne Hilfsmittel von den Objektträgern entfernen
  • Die ungiftige Silikondichtung in medizinischer Qualität kann vor dem Auftragen des Deckglases mit einer Pinzette entfernt werden.
  • “Sandgestrahltes” Schreibfeld ermöglicht die einfache Identifizierung von Proben.
  • Das Deckglas 171080 ist mit dem 16-Well-Kammerobjektträger 178599 zu verwenden.
  • Bestellinformationen:

    • Im 96er- oder 16er-Pack erhältlich.
    • Steriler Versand in stapelbaren Inkubationsschalen.
  • Garantie: 90 Tage
Nur für Forschungszwecke
Specifications
VerschlussfarbeDurchsichtig
Beschreibung2-Well Chamber Slide mit herausnehmbaren Wells
EnthältDurchsichtiger Polystyrol-Deckel mit Griff an der Seite für aseptische Manipulationen
DeckelmaterialPolystyrol
Anzahl pro Packung16
Kulturfläche4,2 cm2
Dimensions (LxW)75 x 25 mm
MaterialPermanox-Kunststoff
SterilitätSteril
OberflächenbehandlungNunclon Delta
Arbeitsvolumen (metrisch)1,2 bis 2,0 ml
Wells2
Unit SizePack of 16
ECM
Have questions about this product? Ask our AI assisted search.
This is an AI-powered search and may not always get things right. You can help us make it better with a thumbs up or down on individual answers or by selecting the “Give feedback" button. Your search history and customer login information may be retained by Thermo Fisher and processed in accordance with our Privacy Notice.

Häufig gestellte Fragen (FAQ)

What cell density should I use for Lab-Tek Chambered Slides and Lab-Tek II Chambered Slides?

Unfortunately, we do not have a recommended cell density for our LabTek Chamber Slides. However, you can refer to the following link, which provides recommended cell densities for our other cell culture products:
https://www.thermofisher.com/us/en/home/references/gibco-cell-culture-basics/cell-culture-protocols/cell-culture-useful-numbers.html

What is the difference between your original Nunc Lab-Tek Chamber Slide System and your Nunc Lab-Tek II Chamber Slide System?

Please review the following key differences between the Nunc Lab-Tek Chamber Slide System and the Nunc Lab-Tek II Chamber Slide System:
- The Nunc Lab-Tek Chamber Slide System is available in Permanox plastic or glass and incorporates a silicone gasket.
- The Nunc Lab-Tek II Chamber Slide System is available in glass only and do not have a silicone gasket.
- The Nunc Lab-Tek II Chamber Slide System has a blue hydrophobic border and the upper structure is attached by an adhesive. Supplied with this product is a key and holder system which is used to remove the upper structure from the glass slide.
- The Nunc Lab-Tek Chamber Slide System is available in 1-, 2-, 4-, 8- or 16-well formats.
- The Nunc Lab-Tek II Chamber Slide System is available in 1-, 2-, 4- or 8-well formats.

Why do cells grow in lines when I am using glass Nunc Lab-Tek Chamber Slide products? How can I prevent this?

The following are possible causes and solutions:
- The cells could be stressed due to media substitution, especially from serum-free formulations, or other changes to the culture environment such as in temperature, humidity, and CO2 percentage. If possible, always plate cells in serum-containing medium. Switching cells to a serum-free media should be done gradually.
- The cells could be plated at very low densities. Most cell lines have a minimal platting density below which normal cell proliferation cannot occur, and therefore should be avoided.
- The cells could be poorly adherent. Treatment of cells that may reduce adhesion and therefore, should not be done immediately after plating, but after the cells have resumed exponential growth.

Can I fix and stain my Nunc Lab-Tek Chamber Slide products with the upper structure still attached?

The upper structure of our Nunc Lab-Tek Chamber Slide products are made of polystyrene so it is not compatible with many fixation reagents. These chamber slide products are designed for upper structure and gasket removal before fixing, staining, and coverslipping.

Can I use my Nunc Lab-Tek Chamber Slide products for fluorescence applications?

Our Nunc Lab-Tek Chamber Slide products are used for fluorescence analyses at the microscopic level.
The following are commonly used excitation and emittance wavelengths:
FITC
- Excitation: 420-490 nm
- Emittance: 520-550 nm
Rhodamine
- Excitation: 510-560 nm
- Emittance: 570-610 nm
Hoechst
- Excitation: 330-380 nm
- Emittance: 480-510 nm