Thermo Scientific™

Orbitrap™ Ascend Editions Tribrid™ Mass Spectrometer

製品番号(カタログ番号): B51003849
Thermo Scientific™

Orbitrap™ Ascend Editions Tribrid™ Mass Spectrometer

製品番号(カタログ番号): B51003849

Exceed experimental expectation and versatility with recommended MultiOmics, Structural Biology, and BioPharma configurations of the Thermo Scientific™ Orbitrap Ascend Editions Tribrid™ Mass Spectrometer. Each Edition provides a tailored configuration of options for each application space, simplifying your decisions and streamlining your research. Characterize even the largest biopharmaceuticals and protein complexes with the Native MS option, which extends the Orbitrap mass range up to m/z 16,000 and new quadrupole isolation up to m/z 8,000. Unlock the potential of alternate fragmentation techniques to decipher the most challenging molecules.

 
製品番号(カタログ番号)
B51003849
容量
Each
概要
Orbitrap Ascend BioPharma Tribrid Mass Spectrometer with PTCR, ETD, UVPD, and Native MS recommended options
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ> 5000 within a single scan
質量範囲40 to 6000 m/z (with recommended options: Mass Range up to 16,000 m/z)
質量確度< 3 ppm RMS using external calibration
読取り速度Up to 45 Hz
極性切換えOne full experimental cycle acquired in < 1.1 seconds
概要Orbitrap Ascend BioPharma Tribrid Mass Spectrometer with PTCR, ETD, UVPD, and Native MS recommended options
寸法(奥行き☓幅☓高さ)34 x 50 x 28 in. (81 x 127 x 70 cm)
重量(メートル法)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
製品番号(カタログ番号)
容量
Each
概要
Orbitrap Ascend Tribrid mass spectrometer, Standard
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ> 5000 within a single scan
質量範囲

m/z 40-6000

質量確度< 3 ppm RMS using external calibration
読取り速度Up to 45 Hz
極性切換え

One full experimental cycle acquired in <1.1 seconds

概要Orbitrap Ascend Tribrid mass spectrometer, Standard
寸法(奥行き☓幅☓高さ)32 x 50 x 28 in. (81 x 127 x 70 cm)
重量(メートル法)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
製品番号(カタログ番号)
容量
Each
概要
Orbitrap Ascend MultiOmics Tribrid Mass Spectrometer with ETD and IC recommended options
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ> 5000 within a single scan
質量範囲40 to 6000 m/z
質量確度< 3 ppm RMS using external calibration
読取り速度Up to 45 Hz
極性切換えOne full experimental cycle acquired in < 1.1 seconds
概要Orbitrap Ascend MultiOmics Tribrid Mass Spectrometer with ETD and IC recommended options
寸法(奥行き☓幅☓高さ)32 x 50 x 28 in. (81 x 127 x 70 cm)
重量(メートル法)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
製品番号(カタログ番号)
容量
Each
概要
Orbitrap Ascend Structural Biology Tribrid Mass Spectrometer with IC/ETD, PTCR, and Native MS recommended options
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ> 5000 within a single scan
質量範囲40 to 6000 m/z (with recommended options: Mass Range up to 16,000 m/z)
質量確度< 3 ppm RMS using external calibration
読取り速度Up to 45 Hz
極性切換えOne full experimental cycle acquired in < 1.1 seconds
概要Orbitrap Ascend Structural Biology Tribrid Mass Spectrometer with IC/ETD, PTCR, and Native MS recommended options
寸法(奥行き☓幅☓高さ)35 x 50 x 28 in. (81 x 127 x 70 cm)
重量(メートル法)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
4 / 4 を表示
製品番号(カタログ番号)仕様容量概要価格(JPY)
B51003849仕様詳細
EachOrbitrap Ascend BioPharma Tribrid Mass Spectrometer with PTCR, ETD, UVPD, and Native MS recommended options見積もりを依頼する
タイプOrbitrap LC-MS
ダイナミックレンジ> 5000 within a single scan
質量範囲40 to 6000 m/z (with recommended options: Mass Range up to 16,000 m/z)
質量確度< 3 ppm RMS using external calibration
読取り速度Up to 45 Hz
極性切換えOne full experimental cycle acquired in < 1.1 seconds
概要Orbitrap Ascend BioPharma Tribrid Mass Spectrometer with PTCR, ETD, UVPD, and Native MS recommended options
寸法(奥行き☓幅☓高さ)34 x 50 x 28 in. (81 x 127 x 70 cm)
重量(メートル法)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
FSN06-10000仕様詳細
EachOrbitrap Ascend Tribrid mass spectrometer, Standard見積もりを依頼する
タイプOrbitrap LC-MS
ダイナミックレンジ> 5000 within a single scan
質量範囲

m/z 40-6000

質量確度< 3 ppm RMS using external calibration
読取り速度Up to 45 Hz
極性切換え

One full experimental cycle acquired in <1.1 seconds

概要Orbitrap Ascend Tribrid mass spectrometer, Standard
寸法(奥行き☓幅☓高さ)32 x 50 x 28 in. (81 x 127 x 70 cm)
重量(メートル法)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
B51003847仕様詳細
EachOrbitrap Ascend MultiOmics Tribrid Mass Spectrometer with ETD and IC recommended options見積もりを依頼する
タイプOrbitrap LC-MS
ダイナミックレンジ> 5000 within a single scan
質量範囲40 to 6000 m/z
質量確度< 3 ppm RMS using external calibration
読取り速度Up to 45 Hz
極性切換えOne full experimental cycle acquired in < 1.1 seconds
概要Orbitrap Ascend MultiOmics Tribrid Mass Spectrometer with ETD and IC recommended options
寸法(奥行き☓幅☓高さ)32 x 50 x 28 in. (81 x 127 x 70 cm)
重量(メートル法)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
B51003848仕様詳細
EachOrbitrap Ascend Structural Biology Tribrid Mass Spectrometer with IC/ETD, PTCR, and Native MS recommended options見積もりを依頼する
タイプOrbitrap LC-MS
ダイナミックレンジ> 5000 within a single scan
質量範囲40 to 6000 m/z (with recommended options: Mass Range up to 16,000 m/z)
質量確度< 3 ppm RMS using external calibration
読取り速度Up to 45 Hz
極性切換えOne full experimental cycle acquired in < 1.1 seconds
概要Orbitrap Ascend Structural Biology Tribrid Mass Spectrometer with IC/ETD, PTCR, and Native MS recommended options
寸法(奥行き☓幅☓高さ)35 x 50 x 28 in. (81 x 127 x 70 cm)
重量(メートル法)181 kg (400 lb)
Max. ResolutionUp to 480,000 at m/z 200
Unit SizeEach
4 / 4 を表示

With three unique fit-for-purpose Editions that are tailored for MultiOmics; Structural Biology; and BioPharma application areas, Orbitrap Ascend Editions Tribrid mass spectrometers ensure high-quality data acquisition. Whether you're focused on multiplexed quantitative proteomics, metabolomics, lipidomics or glycomics, small molecule-based pharmaceuticals or biotherapeutics, single-cell or deciphering higher-order protein structures; these instruments are uniquely suited to your needs.

  • Native MS option: Orbitrap extended mass range up to m/z 16000 and new quadrupole isolation up to m/z 8000 for improved selectivity and MSn sensitivity of macromolecules.
  • PTCR option: Reduce m/z spectrum complexity to enhance proteoform characterization at MS1 and MS2 levels.
  • UVPD option: Improved fragmentation for top-down proteomics, oligonucleotides, lipidomics, and other analytes
  • Easy-ETD option: Achieve high sequence coverage of proteins, including site localization of labile PTMs.
  • EASY-IC ion source option: Obtain sub-1ppm mass accuracy with internal calibration.
  • Dual IRMs: Confidently identify more molecules with two ion-routing multiples to increase scan rate and sensitivity.
  • Real-Time Library Search: Provides higher confidence identifications for peptide or small molecule analysis using MSn.
  • Auto-Ready ion source: Spend less time on instrument setup with a new dedicated source for autocalibration.
  • Pre-built method templates: Optimized methods for each Edition system, covering diverse applications.
  • Dry-Pump: Environmentally friendly, oil-free dry pump is standard to decrease maintenance while providing leak-free vacuum performance.