Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Obtain high confidence insights for very complex molecules with the Thermo Scientific™ Orbitrap Eclipse™ Tribrid™ mass spectrometer. It combines industry-leading versatility and usability with the exceptional performance afforded by its built-in intelligence and revolutionary Thermo Scientific™ Tribrid™ architecture to deliver an instrument designed to address the most difficult analytical challenges. This newest Tribrid platform includes Advanced Ion Management Technology (AIM+) with the new QR5 segmented quadrupole mass filter, Real-Time Search, Enhanced Vacuum Technology, optional Proton Transfer Charge Reduction (PTCR), and optional High Mass Range MSn (HMRn) mode. Collectively, these features make this instrument uniquely suited for accurate and high-throughput full-proteome quantitation, characterization of complex mixtures of protein or small molecule-based pharmaceuticals, and deciphering higher-order protein structures. The Orbitrap Eclipse Tribrid MS makes it easy to tackle these difficult analyses and collect the high-quality data required to drive the right decisions, pushing your science beyond today's discovery.
タイプ | Orbitrap LC-MS |
ダイナミックレンジ | >5000 within one spectrum |
質量範囲 | Standard mass range: 50 to 2000 m/z Mid mass range: 200 to 6000 m/z Optemonal HMRn mass range: 500 to 8000 m/z |
質量確度 | Internal: <1 ppm RMS External: <3 ppm RMS |
分解能 | 500,000 at m/z 200 |
読取り速度 | MSn for n = 1 through 10 |
極性切換え | One Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000)) |
感度 | MS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe. |
概要 | Orbitrap Eclipse Tribrid MS Upgrade to Easy-IC |
重量(メートル法) | 180 kg (400 lb.) without data system, vacuum rough pumps and optional items |
Unit Size | Each |
タイプ | Orbitrap LC-MS |
ダイナミックレンジ | >5000 with a single OTMS spectrum |
質量範囲 | Standard mass range: 50 to 2000 m/z Mid mass range: 200 to 6000 m/z Optemonal HMRn mass range: 500 to 8000 m/z |
質量確度 | Orbitrap mass accuracy: <3 ppm RMS using external calibration <1 ppm RMS using internal calibration |
読取り速度 | OTMSn: Up to 40 Hz ITMSn: Up to 45 Hz |
極性切換え | One Full Cycle in < 1.1 sec |
概要 | Orbitrap Eclipse Tribrid MS |
寸法(奥行き☓幅☓高さ) | 30 x 50 x 28 in. (77 x 127 x 70 cm) |
重量(メートル法) | 180 kg (400 lb.) |
Max. Resolution | Up to 500,000 at m/z 200 |
Unit Size | Each |
タイプ | Orbitrap LC-MS |
ダイナミックレンジ | >5000 with a single OTMS spectrum |
質量範囲 | Standard mass range: 50 to 2000 m/z Mid mass range: 200 to 6000 m/z Optemonal HMRn mass range: 500 to 8000 m/z |
質量確度 | Orbitrap mass accuracy: <3 ppm RMS using external calibration <1 ppm RMS using internal calibration |
分解能 | 7500 to 500,000 (FWHM) at m/z 200 |
読取り速度 | OTMSn: Up to 40 Hz ITMSn: Up to 45 Hz |
極性切換え | One Full Cycle in < 1.1 sec |
概要 | Orbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC) |
寸法(奥行き☓幅☓高さ) | 30 x 50 x 28 in. (77 x 127 x 70 cm) |
重量(メートル法) | 180 kg (400 lb.) |
Unit Size | Each |
タイプ | Orbitrap LC-MS |
ダイナミックレンジ | >5000 with a single OTMS spectrum |
質量範囲 | Standard mass range: 50 to 2000 m/z Mid mass range: 200 to 6000 m/z Optemonal HMRn mass range: 500 to 8000 m/z |
質量確度 | Orbitrap mass accuracy: <3 ppm RMS using external calibration <1 ppm RMS using internal calibration |
分解能 | 7500 to 500,000 (FWHM) at m/z 200 |
読取り速度 | OTMSn: Up to 40 Hz ITMSn: Up to 45 Hz |
極性切換え | One Full Cycle in < 1.1 sec |
概要 | Orbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD) |
寸法(奥行き☓幅☓高さ) | 30 x 50 x 28 in. (77 x 127 x 70 cm) |
重量(メートル法) | 180 kg (400 lb.) |
Unit Size | Each |
タイプ | Orbitrap LC-MS |
ダイナミックレンジ | >5000 with a single OTMS spectrum |
質量範囲 | Standard mass range: 50 to 2000 m/z Mid mass range: 200 to 6000 m/z Optemonal HMRn mass range: 500 to 8000 m/z |
質量確度 | Orbitrap mass accuracy: <3 ppm RMS using external calibration <1 ppm RMS using internal calibration |
分解能 | 7500 to 500,000 (FWHM) at m/z 200 |
読取り速度 | OTMSn: Up to 40 Hz ITMSn: Up to 45 Hz |
極性切換え | One Full Cycle in < 1.1 sec |
概要 | Orbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR) |
寸法(奥行き☓幅☓高さ) | 30 x 50 x 28 in. (77 x 127 x 70 cm) |
重量(メートル法) | 180 kg (400 lb.) |
Unit Size | Each |
タイプ | Orbitrap LC-MS |
ダイナミックレンジ | >5000 within one spectrum |
質量範囲 | Standard mass range: 50 to 2000 m/z Mid mass range: 200 to 6000 m/z Optemonal HMRn mass range: 500 to 8000 m/z |
質量確度 | Internal: <1 ppm RMS External: <3 ppm RMS |
分解能 | 500,000 at m/z 200 |
読取り速度 | MSn for n = 1 through 10 |
極性切換え | One Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000)) |
感度 | MS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe. |
概要 | Orbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR |
重量(メートル法) | 180 kg (400 lb.) without data system, vacuum rough pumps and optional items |
Unit Size | Each |
製品番号(カタログ番号) | 仕様 | 容量 | 概要 | 価格(JPY) | 在庫と納期 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FETD3-10001 | Each | Orbitrap Eclipse Tribrid MS Upgrade to Easy-IC | 見積もりを依頼する | *** | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
FSN04-10000 | Each | Orbitrap Eclipse Tribrid MS | 見積もりを依頼する | *** | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
FSN04-10001 | Each | Orbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC) | 見積もりを依頼する | *** | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
FSN04-10002 | Each | Orbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD) | 見積もりを依頼する | *** | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
FSN04-10003 | Each | Orbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR) | 見積もりを依頼する | *** | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
FETD3-10003 | Each | Orbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR | 見積もりを依頼する | *** | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
With its built-in intelligence and versatility, the Orbitrap Eclipse Tribrid MS makes it easy to produce the high quality data required to drive the right decisions.