Thermo Scientific™

Orbitrap Eclipse™ Tribrid™ Mass Spectrometer

製品番号(カタログ番号): FSN04-10001
Thermo Scientific™

Orbitrap Eclipse™ Tribrid™ Mass Spectrometer

製品番号(カタログ番号): FSN04-10001

Obtain high confidence insights for very complex molecules with the Thermo Scientific™ Orbitrap Eclipse™ Tribrid™ mass spectrometer. It combines industry-leading versatility and usability with the exceptional performance afforded by its built-in intelligence and revolutionary Thermo Scientific™ Tribrid™ architecture to deliver an instrument designed to address the most difficult analytical challenges. This newest Tribrid platform includes Advanced Ion Management Technology (AIM+) with the new QR5 segmented quadrupole mass filter, Real-Time Search, Enhanced Vacuum Technology, optional Proton Transfer Charge Reduction (PTCR), and optional High Mass Range MSn (HMRn) mode. Collectively, these features make this instrument uniquely suited for accurate and high-throughput full-proteome quantitation, characterization of complex mixtures of protein or small molecule-based pharmaceuticals, and deciphering higher-order protein structures. The Orbitrap Eclipse Tribrid MS makes it easy to tackle these difficult analyses and collect the high-quality data required to drive the right decisions, pushing your science beyond today's discovery.

 
製品番号(カタログ番号)
FSN04-10001
容量
Each
概要
Orbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC)
在庫と納期
***
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 with a single OTMS spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Orbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
分解能7500 to 500,000 (FWHM) at m/z 200
読取り速度OTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
極性切換えOne Full Cycle in < 1.1 sec
概要Orbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC)
寸法(奥行き☓幅☓高さ)30 x 50 x 28 in. (77 x 127 x 70 cm)
重量(メートル法)180 kg (400 lb.)
Unit SizeEach
製品番号(カタログ番号)
容量
Each
概要
Orbitrap Eclipse Tribrid MS
在庫と納期
***
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 with a single OTMS spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Orbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
読取り速度OTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
極性切換えOne Full Cycle in < 1.1 sec
概要Orbitrap Eclipse Tribrid MS
寸法(奥行き☓幅☓高さ)30 x 50 x 28 in. (77 x 127 x 70 cm)
重量(メートル法)180 kg (400 lb.)
Max. ResolutionUp to 500,000 at m/z 200
Unit SizeEach
製品番号(カタログ番号)
容量
Each
概要
Orbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD)
在庫と納期
***
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 with a single OTMS spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Orbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
分解能7500 to 500,000 (FWHM) at m/z 200
読取り速度OTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
極性切換えOne Full Cycle in < 1.1 sec
概要Orbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD)
寸法(奥行き☓幅☓高さ)30 x 50 x 28 in. (77 x 127 x 70 cm)
重量(メートル法)180 kg (400 lb.)
Unit SizeEach
製品番号(カタログ番号)
容量
Each
概要
Orbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR)
在庫と納期
***
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 with a single OTMS spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Orbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
分解能7500 to 500,000 (FWHM) at m/z 200
読取り速度OTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
極性切換えOne Full Cycle in < 1.1 sec
概要Orbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR)
寸法(奥行き☓幅☓高さ)30 x 50 x 28 in. (77 x 127 x 70 cm)
重量(メートル法)180 kg (400 lb.)
Unit SizeEach
製品番号(カタログ番号)
容量
Each
概要
Orbitrap Eclipse Tribrid MS Upgrade to Easy-IC
在庫と納期
***
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 within one spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Internal: <1 ppm RMS
External: <3 ppm RMS
分解能500,000 at m/z 200
読取り速度MSn for n = 1 through 10
極性切換えOne Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
感度MS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe.
概要Orbitrap Eclipse Tribrid MS Upgrade to Easy-IC
重量(メートル法)180 kg (400 lb.) without data system, vacuum rough pumps and optional items
Unit SizeEach
製品番号(カタログ番号)
容量
Each
概要
Orbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR
在庫と納期
***
仕様詳細
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 within one spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Internal: <1 ppm RMS
External: <3 ppm RMS
分解能500,000 at m/z 200
読取り速度MSn for n = 1 through 10
極性切換えOne Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
感度MS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe.
概要Orbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR
重量(メートル法)180 kg (400 lb.) without data system, vacuum rough pumps and optional items
Unit SizeEach
6 / 6 を表示
製品番号(カタログ番号)仕様容量概要価格(JPY)在庫と納期
FSN04-10001仕様詳細
EachOrbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC)見積もりを依頼する***
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 with a single OTMS spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Orbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
分解能7500 to 500,000 (FWHM) at m/z 200
読取り速度OTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
極性切換えOne Full Cycle in < 1.1 sec
概要Orbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC)
寸法(奥行き☓幅☓高さ)30 x 50 x 28 in. (77 x 127 x 70 cm)
重量(メートル法)180 kg (400 lb.)
Unit SizeEach
FSN04-10000仕様詳細
EachOrbitrap Eclipse Tribrid MS見積もりを依頼する***
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 with a single OTMS spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Orbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
読取り速度OTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
極性切換えOne Full Cycle in < 1.1 sec
概要Orbitrap Eclipse Tribrid MS
寸法(奥行き☓幅☓高さ)30 x 50 x 28 in. (77 x 127 x 70 cm)
重量(メートル法)180 kg (400 lb.)
Max. ResolutionUp to 500,000 at m/z 200
Unit SizeEach
FSN04-10002仕様詳細
EachOrbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD)見積もりを依頼する***
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 with a single OTMS spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Orbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
分解能7500 to 500,000 (FWHM) at m/z 200
読取り速度OTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
極性切換えOne Full Cycle in < 1.1 sec
概要Orbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD)
寸法(奥行き☓幅☓高さ)30 x 50 x 28 in. (77 x 127 x 70 cm)
重量(メートル法)180 kg (400 lb.)
Unit SizeEach
FSN04-10003仕様詳細
EachOrbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR)見積もりを依頼する***
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 with a single OTMS spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Orbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
分解能7500 to 500,000 (FWHM) at m/z 200
読取り速度OTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
極性切換えOne Full Cycle in < 1.1 sec
概要Orbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR)
寸法(奥行き☓幅☓高さ)30 x 50 x 28 in. (77 x 127 x 70 cm)
重量(メートル法)180 kg (400 lb.)
Unit SizeEach
FETD3-10001仕様詳細
EachOrbitrap Eclipse Tribrid MS Upgrade to Easy-IC見積もりを依頼する***
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 within one spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Internal: <1 ppm RMS
External: <3 ppm RMS
分解能500,000 at m/z 200
読取り速度MSn for n = 1 through 10
極性切換えOne Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
感度MS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe.
概要Orbitrap Eclipse Tribrid MS Upgrade to Easy-IC
重量(メートル法)180 kg (400 lb.) without data system, vacuum rough pumps and optional items
Unit SizeEach
FETD3-10003仕様詳細
EachOrbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR見積もりを依頼する***
タイプOrbitrap LC-MS
ダイナミックレンジ>5000 within one spectrum
質量範囲Standard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
質量確度Internal: <1 ppm RMS
External: <3 ppm RMS
分解能500,000 at m/z 200
読取り速度MSn for n = 1 through 10
極性切換えOne Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
感度MS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe.
概要Orbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR
重量(メートル法)180 kg (400 lb.) without data system, vacuum rough pumps and optional items
Unit SizeEach
6 / 6 を表示

With its built-in intelligence and versatility, the Orbitrap Eclipse Tribrid MS makes it easy to produce the high quality data required to drive the right decisions.

  • Exceptional precursor selectivity and sensitivity with the next generation quadrupole mass filter
  • Unmatched depth and accuracy of TMT analysis with novel Real-Time Search
  • High Mass Range MSn (HMRn) option for comprehensive analysis of native protein complexes
  • Unique Proton Transfer Charge Reduction (PTCR) option for simplifying complex top-down spectra
  • Full experimental flexibility with revolutionary instrument control
  • A wide range of optional functionalities for unprecedented versatility
  • Common user interface with Thermo Scientific™ Orbitrap Exploris™ 480 and TSQ™ triple quadrupole mass spectrometers

ドキュメントおよびダウンロード

証明書

    よくあるご質問(FAQ)

    引用および参考文献

    Search citations by name, author, journal title or abstract text