Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Cell Isolation and Cell Separation |
Cell isolation helps researchers characterize specific, pure cell populations. Cell depletion indirectly helps this characterization by depleting the cells that are not of interest. Cell isolation, also commonly referred to as cell separation or cell sorting, can be achieved using magnetic beads to target cells for selection or depletion by using ligands or antibodies directed against specific cell surface antigens. Labeled cells that are cross-linked to magnetic beads are immobilized using magnets or magnetic racks. This method is simpler and faster compared to other commonly used cell isolation methods to isolate highly purified populations of specific cell subsets.
Magnetic bead cell separation methods offer the capability to perform positive and negative cell selection, as well as cell depletion. For positive selection, the magnetic-bound cells of interest are immobilized until removed from the magnet, while the supernatant is discarded. For negative selection, the cells of interest are in the supernatant. For cell depletion, cell-specific magnetic beads are used to remove specific unwanted cell types from a mixed cell sample with >99% efficiency.
Read more about positive and negative selection and depletion, as well as view our variety of kits and products to help improve your cell isolation protocols.
Cell depletion is aided by cell separation steps using magnetic beads. Cell depletion using magnetic beads involves selectively removing specific unwanted cells from a mixed population by using magnetic beads coupled with antibodies or ligands targeting specific cell surface markers. Through exposure to a magnetic field, the bead-bound unwanted cells are separated and removed from sample, allowing the isolation of desired cell populations for downstream characterization and analysis.
![]() | Cell depletion kits are available to target specific human cell surface markers to deplete certain cell populations, which can be found in the table below. |
Cell type to deplete | Cell surface marker(s) to target for depletion |
---|---|
T cells and natural killer (NK) cells | CD2 |
Mature T cells | CD3 |
T helper cells | CD4 |
Cytotoxic T cells | CD8 |
Monocytes | CD14 |
Neutrophil and eosinophil granulocytes | CD15 |
Pan B cells | CD19 |
Regulatory T cells | CD25 |
Endothelial cells | CD31 |
Leukocytes | CD45 |
Epithelial cells | EPCAM |
Automated protocol description | Supporting products | Download automation scripts |
---|---|---|
Cell depletion or positive cell isolation for downstream nucleic acid, protein analysis, or cell depletion |
|
![]() | Cell depletion kits are available to target specific mouse cell surface markers to deplete certain cell populations, which can be found in the table below. |
Cell type to deplete | Cell surface marker(s) to target for depletion |
---|---|
CD4+ T cells | CD4 |
CD8+ T cells | CD8 |
Pan B cells | B220 |
Pan T cells | Thy1.2 |
Build your own kit and attach your own antibody for custom cell targeting.
Target cell species | Recommended antibody | Suggested product |
---|---|---|
Any species (except mouse) | Mouse IgG | Dynabeads Pan Mouse IgG |
Mouse IgG1, IgG2a, and IgG2b | Dynabeads Sheep Anti-Mouse IgG | |
Mouse IgG | Dynabeads Goat Anti-Mouse IgG | |
Mouse IgM | Dynabeads Rat Anti-Mouse IgM | |
Any species (except rat) | Rat IgG | Dynabeads Sheep Anti-Rat IgG |
Any species (except rabbit) | Rabbit IgG | Dynabeads M-280 Sheep Anti–Rabbit IgG |
Any species | Biotinylated antibody | Dynabeads Biotin Binder |
Dynabeads MyOne Streptavidin T1 | ||
Any purified antibody/ligand | Dynabeads M-450 Epoxy | |
Dynabeads M-450 Tosylactivated | ||
Dynabeads Antibody Coupling Kit* |
* The Dynabeads Antibody Coupling Kits contain buffers for optimal coupling conditions.
Positive cell isolation involves directly labeling desired cells for selection using an antibody or ligand that targets a specific cell surface protein.
In positive cell isolation using Dynabeads magnetic beads, the beads are coated with the specific antibody or ligand to bind to the target cells and the bead/cell complexes are pulled down using a magnet. The supernatant contains non-specific cells and debris which can be discarded, leaving only your pure target cells attached to the bead.
Cell separation using magnetic beads:
![]() | Positive cell isolation kits available for human cells target the following cell surface markers: |
Cell surface marker to target for isolation | Cell type targeted | Format(s) available |
---|---|---|
CD3 | Cytotoxic T cells and T helper cells | FlowComp kit |
CD4 | T helper cells, regulatory T cells, and natural killer T cells | FlowComp kit |
CD8 | Cytotoxic T cells | FlowComp kit DETACHaBEAD kit |
CD14 | CD14+ monocytes | FlowComp kit |
CD19 | Pan B cells | DETACHaBEAD kit |
CD34 | Progenitor stem cells | DETACHaBEAD kit |
CD4/CD25 | Regulatory CD4+ T cells | DETACHaBEAD kit |
EPCAM | Epithelial cells | CELLection kit |
Automated protocol description | Supporting products | Download automation scripts |
---|---|---|
Positive cell isolation for downstream cellular applications, such as T cell activation |
|
![]() | Positive cell isolation kits available for mouse cells target the following cell surface markers: |
Cell surface marker to target for isolation | Cell type targeted | Format(s) available |
---|---|---|
CD4 | Naive CD4+ T cells | FlowComp kit |
CD8 | Naive CD8+ T cells | FlowComp kit |
CD4/CD25 | Regulatory CD4+ T cells | FlowComp kit |
CD90.2 | Pan T cells | FlowComp kit |
Pan IgG | Depends on your antibody | CELLection kit |
In contrast to column-based systems, FlowComp technology lets you isolate bead-free cells directly from human whole blood, buffy coat, or from mouse/human mononuclear cells (MNCs). Following separation, the beads are immediately released and removed, helping ensure the least possible interaction with your cells. Isolated bead-free cells are then ready for use in any downstream application, including flow cytometry. Get high cell recovery, viability, and purity using FlowComp kits and markers.
Additional positive cell isolation kits are available to use for a wide range of species, with any antibody of your choice.
Use with | Format available |
---|---|
Any antibody targeting any cell type in any species | FlowComp kit |
Any biotinylated antibody targeting any cell type in any species | CELLection kit |
Negative cell involves labeling unwanted cell types for removal. The unwanted cell types can be bound using magnetic beads coupled to antibodies or ligands that target specific cell surface proteins. The bound, unwanted cells can be depleted from the final isolated fraction by incubating the sample in a magnetic field, leaving desired unbound cells free floating in solution.
In negative cell isolation, Dynabeads magnetic beads are used to deplete all the unwanted cells using the supplied antibody mix. The target cells are left in the sample untouched and free of beads. The isolated target cells can be directly analyzed in a flow cytometer and used in any functional assay.
Negative cell separation using magnetic beads:
![]() | Negative cell isolation kits are available for human cells to target the following cell types: |
Enriched untouched cell type | Surface markers on depleted cells | Format available |
---|---|---|
CD4+ T cells: T helper cells, regulatory T cells, and natural killer T cells | CD8, CD14, CD16 (a and b), CD19, CD36, CD56, CDw123 and CD235a | Untouched kit |
CD8+ T cells: cytotoxic T cells | CD4, CD14, CD16 (a and b), CD19, CD36, CD56, CDw123 and CD235a | Untouched kit |
Dendritic cells (DCs) | CD3, CD14, CD16, CD19, CD56, and CD235a | Untouched kit |
Monocytes | CD3, CD7, CD16 (a and b), CD19, CD56, CD123, and CD235a | Untouched kit |
Pan B cells | CD2, CD14, CD16 (a and b), CD36, CD43, and CD235a | Untouched kit |
Pan T cells | CD14, CD16 (a and b), CD19, CD36, CD56, CD123, and CD235a | Untouched kit |
Natural killer (NK) cells | CD3, CD14, CD36, HLA Class II, CD123, and CD235a | Untouched kit |
![]() | Negative cell isolation kits are available for mouse cells to target the following cell types: |
Enriched untouched cell type | Surface markers on depleted cells | Format available |
---|---|---|
Naive CD4+ T cells | CD8, CD45R (B220), CD11b (Mac1), Ter-119, and CD16/CD32 | Untouched kit |
Naive CD8+ T cells | CD4, CD45R (B220), CD11b (Mac1), Ter-119, and CD16/CD32 | Untouched kit |
Dendritic cells (DCs) | CD2, CD3ε, CD49b, mIgM, and Ter-119 | Dynabeads kit |
Pan B cells | CD43 | Dynabeads kit |
Pan T cells | CD11b, CD16/32, CD45R, and Ter-119 | Untouched kit |
Cell depletion is aided by cell separation steps using magnetic beads. Cell depletion using magnetic beads involves selectively removing specific unwanted cells from a mixed population by using magnetic beads coupled with antibodies or ligands targeting specific cell surface markers. Through exposure to a magnetic field, the bead-bound unwanted cells are separated and removed from sample, allowing the isolation of desired cell populations for downstream characterization and analysis.
![]() | Cell depletion kits are available to target specific human cell surface markers to deplete certain cell populations, which can be found in the table below. |
Cell type to deplete | Cell surface marker(s) to target for depletion |
---|---|
T cells and natural killer (NK) cells | CD2 |
Mature T cells | CD3 |
T helper cells | CD4 |
Cytotoxic T cells | CD8 |
Monocytes | CD14 |
Neutrophil and eosinophil granulocytes | CD15 |
Pan B cells | CD19 |
Regulatory T cells | CD25 |
Endothelial cells | CD31 |
Leukocytes | CD45 |
Epithelial cells | EPCAM |
Automated protocol description | Supporting products | Download automation scripts |
---|---|---|
Cell depletion or positive cell isolation for downstream nucleic acid, protein analysis, or cell depletion |
|
![]() | Cell depletion kits are available to target specific mouse cell surface markers to deplete certain cell populations, which can be found in the table below. |
Cell type to deplete | Cell surface marker(s) to target for depletion |
---|---|
CD4+ T cells | CD4 |
CD8+ T cells | CD8 |
Pan B cells | B220 |
Pan T cells | Thy1.2 |
Build your own kit and attach your own antibody for custom cell targeting.
Target cell species | Recommended antibody | Suggested product |
---|---|---|
Any species (except mouse) | Mouse IgG | Dynabeads Pan Mouse IgG |
Mouse IgG1, IgG2a, and IgG2b | Dynabeads Sheep Anti-Mouse IgG | |
Mouse IgG | Dynabeads Goat Anti-Mouse IgG | |
Mouse IgM | Dynabeads Rat Anti-Mouse IgM | |
Any species (except rat) | Rat IgG | Dynabeads Sheep Anti-Rat IgG |
Any species (except rabbit) | Rabbit IgG | Dynabeads M-280 Sheep Anti–Rabbit IgG |
Any species | Biotinylated antibody | Dynabeads Biotin Binder |
Dynabeads MyOne Streptavidin T1 | ||
Any purified antibody/ligand | Dynabeads M-450 Epoxy | |
Dynabeads M-450 Tosylactivated | ||
Dynabeads Antibody Coupling Kit* |
* The Dynabeads Antibody Coupling Kits contain buffers for optimal coupling conditions.
Positive cell isolation involves directly labeling desired cells for selection using an antibody or ligand that targets a specific cell surface protein.
In positive cell isolation using Dynabeads magnetic beads, the beads are coated with the specific antibody or ligand to bind to the target cells and the bead/cell complexes are pulled down using a magnet. The supernatant contains non-specific cells and debris which can be discarded, leaving only your pure target cells attached to the bead.
Cell separation using magnetic beads:
![]() | Positive cell isolation kits available for human cells target the following cell surface markers: |
Cell surface marker to target for isolation | Cell type targeted | Format(s) available |
---|---|---|
CD3 | Cytotoxic T cells and T helper cells | FlowComp kit |
CD4 | T helper cells, regulatory T cells, and natural killer T cells | FlowComp kit |
CD8 | Cytotoxic T cells | FlowComp kit DETACHaBEAD kit |
CD14 | CD14+ monocytes | FlowComp kit |
CD19 | Pan B cells | DETACHaBEAD kit |
CD34 | Progenitor stem cells | DETACHaBEAD kit |
CD4/CD25 | Regulatory CD4+ T cells | DETACHaBEAD kit |
EPCAM | Epithelial cells | CELLection kit |
Automated protocol description | Supporting products | Download automation scripts |
---|---|---|
Positive cell isolation for downstream cellular applications, such as T cell activation |
|
![]() | Positive cell isolation kits available for mouse cells target the following cell surface markers: |
Cell surface marker to target for isolation | Cell type targeted | Format(s) available |
---|---|---|
CD4 | Naive CD4+ T cells | FlowComp kit |
CD8 | Naive CD8+ T cells | FlowComp kit |
CD4/CD25 | Regulatory CD4+ T cells | FlowComp kit |
CD90.2 | Pan T cells | FlowComp kit |
Pan IgG | Depends on your antibody | CELLection kit |
In contrast to column-based systems, FlowComp technology lets you isolate bead-free cells directly from human whole blood, buffy coat, or from mouse/human mononuclear cells (MNCs). Following separation, the beads are immediately released and removed, helping ensure the least possible interaction with your cells. Isolated bead-free cells are then ready for use in any downstream application, including flow cytometry. Get high cell recovery, viability, and purity using FlowComp kits and markers.
Additional positive cell isolation kits are available to use for a wide range of species, with any antibody of your choice.
Use with | Format available |
---|---|
Any antibody targeting any cell type in any species | FlowComp kit |
Any biotinylated antibody targeting any cell type in any species | CELLection kit |
Negative cell involves labeling unwanted cell types for removal. The unwanted cell types can be bound using magnetic beads coupled to antibodies or ligands that target specific cell surface proteins. The bound, unwanted cells can be depleted from the final isolated fraction by incubating the sample in a magnetic field, leaving desired unbound cells free floating in solution.
In negative cell isolation, Dynabeads magnetic beads are used to deplete all the unwanted cells using the supplied antibody mix. The target cells are left in the sample untouched and free of beads. The isolated target cells can be directly analyzed in a flow cytometer and used in any functional assay.
Negative cell separation using magnetic beads:
![]() | Negative cell isolation kits are available for human cells to target the following cell types: |
Enriched untouched cell type | Surface markers on depleted cells | Format available |
---|---|---|
CD4+ T cells: T helper cells, regulatory T cells, and natural killer T cells | CD8, CD14, CD16 (a and b), CD19, CD36, CD56, CDw123 and CD235a | Untouched kit |
CD8+ T cells: cytotoxic T cells | CD4, CD14, CD16 (a and b), CD19, CD36, CD56, CDw123 and CD235a | Untouched kit |
Dendritic cells (DCs) | CD3, CD14, CD16, CD19, CD56, and CD235a | Untouched kit |
Monocytes | CD3, CD7, CD16 (a and b), CD19, CD56, CD123, and CD235a | Untouched kit |
Pan B cells | CD2, CD14, CD16 (a and b), CD36, CD43, and CD235a | Untouched kit |
Pan T cells | CD14, CD16 (a and b), CD19, CD36, CD56, CD123, and CD235a | Untouched kit |
Natural killer (NK) cells | CD3, CD14, CD36, HLA Class II, CD123, and CD235a | Untouched kit |
![]() | Negative cell isolation kits are available for mouse cells to target the following cell types: |
Enriched untouched cell type | Surface markers on depleted cells | Format available |
---|---|---|
Naive CD4+ T cells | CD8, CD45R (B220), CD11b (Mac1), Ter-119, and CD16/CD32 | Untouched kit |
Naive CD8+ T cells | CD4, CD45R (B220), CD11b (Mac1), Ter-119, and CD16/CD32 | Untouched kit |
Dendritic cells (DCs) | CD2, CD3ε, CD49b, mIgM, and Ter-119 | Dynabeads kit |
Pan B cells | CD43 | Dynabeads kit |
Pan T cells | CD11b, CD16/32, CD45R, and Ter-119 | Untouched kit |
KingFisher instruments automate the isolation of DNA, RNA, proteins, exosomes, viruses, and cells. KingFisher instruments help eliminate cross contamination and produce reproducible results. Protocol time will vary depending on the target and type of beads.
Learn more about KingFisher instruments for automated protocols
View publications on Dynabeads Streptavidin magnetic beads
View publications on Dynabeads magnetic beads for immunoprecipitation
For simpler, faster, and significant cost savings compared to traditional column-based separation methods, use MagniSort technology to obtain enriched T cells, B cells, and NK cells.
Learn more about MagniSort magnetic cell separation technology
For Research Use Only. Not for use in diagnostic procedures.