Organism TypePrimate - Non HumanThis is an African green monkey kidney fibroblast-like cell line suitable for transfection by vectors requiring expression of SV40 T antigen. This line contains T antigen, retains complete permissiveness for lytic growth of SV40, supports the replication of ts A209 virus at 40C, and supports the replication of pure populations of SV40 mutants with deletions in the early region. The line was derived from the CV-1 cell line (ATCC CCL-70) by transformation with an origin defective mutant of SV40 which codes for wild type T antigen. GIBCO brand cell line is a clonal isolate (COS-7L) adapted to serum-free monolayer culture.
TissuesKidney
PhenotypeAdherent
Primaryno
ApplicationCell Culture / Growth Conditions,Protein Expression,Stable Cell Transfection,Transfection: Gene Expression,Transfection: Gene Silencing,Transient Transfection

Recommended Transfection Reagents

  • Plasmid DNA transfection and co-transfection: Lipofectamine® 3000 (51-79% transfection efficiency and 4 fold protein expression improvement over Lipofectamine® 2000)
  • RNAi transfection (siRNA/miRNA) and gene silencing: Lipofectamine® RNAiMAX

Products

Catalog # Name Size Price (USD) Qty
0020040DJ Custom Media: OPTI PRO SFM 1 each -
10313021 DMEM, high glucose, pyruvate, no glutamine, 500 mL Each
34.65

Online Exclusive

39.83
Save 5.18 (13%)
10459014 DMRIE-C Transfection Reagent Each
724.00
10566016 DMEM, high glucose, GlutaMAX™ Supplement, 500 mL Each
41.65

Online Exclusive

45.95
Save 4.30 (9%)
10567014 DMEM, low glucose, GlutaMAX™ Supplement, pyruvate, 500 mL Each
48.14
10687010 Hygromycin B (50 mg/mL) Each
278.00
11058021 Opti-MEM™ I Reduced Serum Medium, no phenol red Each
74.75
11140050 MEM Non-Essential Amino Acids Solution (100X), 100 mL Each
25.65

Online Exclusive

28.42
Save 2.77 (10%)
11360070 Sodium Pyruvate (100 mM) Each
15.91
11514015 PLUS™ Reagent 0.85 mL
380.00
11668019 Lipofectamine™ 2000 Transfection Reagent, 1.5 mL Each
804.65

Online Exclusive

882.00
Save 77.35 (9%)
11668027 Lipofectamine™ 2000 Transfection Reagent, 0.75 mL Each
519.65

Online Exclusive

562.00
Save 42.35 (8%)
11681020 VP-SFM (1X) Each
137.00
11765054 Ham's F-12 Nutrient Mix, 500 mL 500 mL
36.65

Online Exclusive

39.74
Save 3.09 (8%)
11811023 Geneticin™ Selective Antibiotic (G418 Sulfate), Powder, 1 g Each
167.65

Online Exclusive

182.00
Save 14.35 (8%)
11875093 RPMI 1640 Medium, 500 mL Each
35.56
11965084 DMEM, high glucose, 1000 mL Each
52.65

Online Exclusive

57.75
Save 5.10 (9%)
11965092 DMEM, high glucose, 500 mL Each
32.65

Online Exclusive

35.34
Save 2.69 (8%)
11965118 DMEM, high glucose, 10 x 500 mL Each
276.65

Online Exclusive

304.00
Save 27.35 (9%)
11965126 DMEM, high glucose, 6 x 1000 mL Each
266.65

Online Exclusive

293.00
Save 26.35 (9%)
12100061 DMEM, powder, high glucose, 10 L Each
34.65

Online Exclusive

36.49
Save 1.84 (5%)
12252011 Oligofectamine™ Transfection Reagent Each
694.00
12274015 Gateway™ pcDNA™-DEST40 Vector Each
868.00
12395026 12395026 -
12500096 DMEM/F-12, powder, 50 L Each
239.00
15140122 Penicillin-Streptomycin (10,000 U/mL), 100 mL Each
31.45
15140148 Penicillin-Streptomycin (10,000 U/mL), 20 mL Each
16.62
15338100 Lipofectamine™ LTX Reagent with PLUS™ Reagent, 1 mL Each
814.65

Online Exclusive

896.00
Save 81.35 (9%)
15338500 Lipofectamine™ LTX Reagent Each
12,080.00
15596018 TRIzol™ Reagent, 200 mL Each
463.00
16170086 Bovine Serum, New Zealand origin, 100 mL Each
38.41
18292011 Lipofectin™ Transfection Reagent, 1 mL Each
678.00
18324012 Lipofectamine™ Transfection Reagent, 1 mL Each
650.00
18324020 Lipofectamine™ Transfection Reagent, 4 mL Each
2,200.00
25030149 L-Glutamine (200 mM), 20 mL Each
12.65

Online Exclusive

13.96
Save 1.31 (9%)
26140079 Fetal Bovine Serum, qualified, United States, 500 mL Each -
31985062 Opti-MEM™ I Reduced Serum Medium, 100 mL Each
29.65

Online Exclusive

32.67
Save 3.02 (9%)
430018 PCDNA3.1(+) KIT 1 each -
K278001 Calcium Phosphate Transfection Kit Each
700.00
P41050 Electroporation Cuvettes, 0.1 cm Each
305.00
P46050 Electroporation Cuvettes, 0.4 cm Each
294.65

Online Exclusive

304.00
Save 9.35 (3%)
V04450 pCEP4 Mammalian Expression Vector 20 µg
990.00
V26020 pVAX1 Vector 20 µg
940.00
V79020 pcDNA™3.1 (+) Mammalian Expression Vector 20 µg
1,062.00
V86420 pcDNA™4/HisMax A, B, & C Mammalian Expression Vectors 20 µg
1,166.00

Every step of the way, a wide range of cell health products

Maintaining healthy cells is the key to experimental success and reproducible research results. To give you confidence in the health of your cells every step of the way, we’ve highlighted the technologies and products within cell biology that are critical to maintaining optimal cell health. No matter how you are using your cells, you can count on these products to help keep them healthy.